CCA250 residual chlorine circulation tank bracket

CCA250 residual chlorine circulation tank bracket

FLOWFIT-W CCA250

Configurable Models 1 models
Flow device, suitable for measuring residual chlorine in drinking water, industrial water, and pool water
Compare

Disinfection

Measuring Principle
Application Drinking water, water, waste water, pool, process
Characteristic - Flow through holder with 3 different emplacements : 1x chlorine/chlordioxide/total chlorine sensor and 2x pH/ORP sensor.
Design - Flow through holder made of plexiglas with flow control and proximity switch as alarm relais to the transmitter.
- Three different emplacements
- Calibration directly in the holder because of the screw off calibration cap.
- Optional cleaning device for the chlorine/chlordioxide/total chlorine sensor.
Material Plexiglas (PMMA)
Dimension 85mm x 85mm x 240mm
Process temperature max. 45°C
Process pressure max. 4bar

The Flowfit CCA250 flow assembly is specially designed for installing all sensors used in precise disinfection process control, such as free chlorine sensors and pH/ORP electrodes for compensation and measurement. It increases the applicability of the sensors, provides integrated flow alarm and adjustment, and always ensures bypass measurement. With the CCA250, the entire disinfection process can be controlled, keeping the water free of bacteria at all times.

 

Advantages

All sensors required for the disinfection process are installed together in one holder

Suitable for disinfection process measurement - free chlorine, chlorine dioxide, total chlorine and other parameters

Bottom threaded cap design allows calibration of the pH and ORP electrodes without removing the sensors

Flow alarm function can be activated

Needle valve for flow adjustment and flowmeter for visual control

 

Areas of application

The CCA250 flow assembly is used to install free chlorine, total chlorine and chlorine dioxide sensors for the following measurement applications:

 

Drinking water

- Trace or standard measurement in water treatment processes and water supply networks

- Monitoring, control and optimization of the disinfection process

Utilities

- Trace or standard measurement in various disinfection processes

- Process applications, e.g. bottle washing machines

Swimming pool water

Spare Parts & Accessories 14

14 spare parts · click to expand
Order codeDescription
51517544***CCA250 有机玻璃壳体Enquire
71279209支架固定帽带O型圈Enquire
71279210CCA250备件:带O型圈针阀and locking screw M4x16Enquire
71279211CCA250备件:CCS盲头Pressing screw, o-ring, blind plugEnquire
71279212CCA250紧固组件Enquire
71279213CCA250备件:流动模块 316Tiwith blind plugEnquire
71279214CCA250备件:盲头2x PG13,5 with thrust collar and o-ring Blind plug for float element with o-ring Blind plug CCS completeEnquire
71279208CCA250备件:O型圈Enquire
71279215CCA250 等电势位钛材316Enquire
71372025CCA250适配器套件CCS5x + CCS5xDDetails
50015691感应接近开关Alte Material-Nummer: 117298Enquire
50003228适配器2 pcs. DA16 for pipe connectionEnquire
50003230接头Hose connection: 2 pcs. D6/12Enquire
50003232接头Hose connection: 1pc D6/12 and 1pc D16Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
1 models · click to expand
Model Name
CCA250-A0 Free chlorine flow-through holder
All documents for this model
5 documents · click to expand
BA

Operating Instructions CCA250 English

Rev. 0709 20 pages
Preview
BA

Operating Instructions CCA 250 English

12 pages
Preview
TI

技术资料 Flowfit CCA250 Chinese

Rev. 0709 8 pages
Preview
TI

Technical Information CCA 250 English

Rev. 0709 8 pages
Preview
TI

Technical Information CCA 250 English

4 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · sterilize — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is sterilize; the focus is monitoring and controlling disinfectant dosing and efficacy.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with matching monitoring points to the disinfection route (chlorine, UV, ozone).

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on matching monitoring points to the disinfection route (chlorine, UV, ozone), and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means on-demand dosing, lowering both by-products and cost, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · sterilize — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on sterilize and the core task is monitoring and controlling disinfectant dosing and efficacy.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So sterilize cannot be specified generically — it calls for matching monitoring points to the disinfection route (chlorine, UV, ozone).

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves matching monitoring points to the disinfection route (chlorine, UV, ozone), with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is on-demand dosing, lowering both by-products and cost.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · sterilize — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted sterilize properly configured on the existing plant, with the aim of monitoring and controlling disinfectant dosing and efficacy.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the sterilize configuration has to involve matching monitoring points to the disinfection route (chlorine, UV, ozone).

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant matching monitoring points to the disinfection route (chlorine, UV, ozone), checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is on-demand dosing, lowering both by-products and cost, and the readings are now used for process tuning.

Power & Energy

Power & Energy · sterilize — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was monitoring and controlling disinfectant dosing and efficacy.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means matching monitoring points to the disinfection route (chlorine, UV, ozone).

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around matching monitoring points to the disinfection route (chlorine, UV, ozone), with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome