CCS120D Total Chlorine SensorDiscontinued

CCS120D Total Chlorine Sensor
Memosens CCS120DDiscontinued
Endress+Hauser CCS120D
Memosens digital disinfectant sensor, suitable for sewage and process water applications
Compare

Disinfection

Measuring Principle Total chlorine
Application Wastewater treatment plants, disinfection monitoring and control in wastewater outlet, reuse of outlet water, utilities of all industries, all disinfection measuring points
Characteristic Amperometric measurement of total chlorine
Measuring range 0.1 to 10 mg/l total chlorine
Measuring method Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)
All components are reduced at the working electrode
Almost pH independent
Design Closed, membrane covered measuring cell
Material Sensor shaft: PVC
Membrane: PET
Membrane cap: PPE
Dimension Diameter: 25 mm (0.98 inch)
Length: 148 mm (5.83 inch)
Process temperature 5 to 45 °C
(41 to 113 °F)
Process pressure 1 to 4 bar (14.5 to 58 psi)
Temperature sensor 10k NTC integrated (Memosens)
Connection Inductive, digital connection head with Memosens

Total chlorine is the collective term for free chlorine and combined chlorine, and is also an indicator of the residual disinfectant concentration in discharged water. The CCS120D reliably monitors the total chlorine limit at the outlet. The convenient replacement of the electrolyte and membrane cap significantly reduces maintenance costs. The CCS120D uses Memosens digital technology with maximum process safety and data integrity. The sensor is moisture- and corrosion-resistant and can be calibrated in the laboratory for predictive maintenance.

Benefits
Simple operation thanks to Memosens digital technology
Storage of sensor and process parameters enables predictive maintenance
Fast replacement of membrane cap and electrolyte, low maintenance workload
Flexible installation in the CYA112 immersion holder or the CCA250 flow-through holder
Used together with the Liquiline multichannel transmitter, other relevant water quality parameters can be measured simultaneously.

Applications
The Memosens CCS120D is used for total chlorine measurement:
Wastewater treatment plants
- Disinfectant monitoring and control at the wastewater outlet
- Outlet water recycling and reuse
Utilities in all industries
- All disinfection measuring points

 

Spare Parts & Accessories 6

6 spare parts · click to collapse
Order codeDescription
71412917Kit CCS120/120D, Maintenance KitContent: Electrolyte 50 ml/ 1.69 fl.oz. 2x membrane capDetails
71412916Kit CCS120/120D, electrolyte 50 mlContent: Electrolyte 50 ml/ 1.69 fl.oz.Details
51516343Electrolyte, Total Chlorine Sensor CCS120Electrolyte,Total Chlorine Sensor CCS120Details
51517284Maintenance Kit, CCS120two membrane caps, electrolyteDetails
71105209Viton O-ring2 pieces, replacement for silicone ringDetails
71257946Handheld DPD Colorimetric Calibrator PF-3colorimetric measurement of free and total chlorine 0,05 - 6mg/l Disinfection, drinking and process water hand held photometer, IP67-graded, with cuvettes, DPD, according to ISO 7393 delivery in plastic case, test kit for free and total chlorine included hand-held photometer for calibration and verification of disinfection loopsDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

BA CCS120D Chinese

Rev. 0425 44 pages
Preview
BA

BA CCS120D English

Rev. 0425 44 pages
Preview
TI

TI CCS120D Chinese

Rev. 0219 12 pages
Preview
TI

TI CCS120D English

Rev. 0219 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · sterilize — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is sterilize; the focus is monitoring and controlling disinfectant dosing and efficacy.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with matching monitoring points to the disinfection route (chlorine, UV, ozone).

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on matching monitoring points to the disinfection route (chlorine, UV, ozone), and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means on-demand dosing, lowering both by-products and cost, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · sterilize — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on sterilize and the core task is monitoring and controlling disinfectant dosing and efficacy.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So sterilize cannot be specified generically — it calls for matching monitoring points to the disinfection route (chlorine, UV, ozone).

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves matching monitoring points to the disinfection route (chlorine, UV, ozone), with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is on-demand dosing, lowering both by-products and cost.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · sterilize — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted sterilize properly configured on the existing plant, with the aim of monitoring and controlling disinfectant dosing and efficacy.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the sterilize configuration has to involve matching monitoring points to the disinfection route (chlorine, UV, ozone).

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant matching monitoring points to the disinfection route (chlorine, UV, ozone), checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is on-demand dosing, lowering both by-products and cost, and the readings are now used for process tuning.

Power & Energy

Power & Energy · sterilize — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was monitoring and controlling disinfectant dosing and efficacy.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means matching monitoring points to the disinfection route (chlorine, UV, ozone).

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around matching monitoring points to the disinfection route (chlorine, UV, ozone), with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — on-demand dosing, lowering both by-products and cost, with routine maintenance falling noticeably.