The Oxymax COS22D protects the medium, the process and the plant equipment from the effects of oxygen. It measures reliably over its measuring range, helping users monitor and control conditions better. The sensor has low maintenance requirements and high long-term stability, and can be used in applications with frequent steam sterilization and high-temperature sterilization. With Memosens digital technology, the COS22D offers maximum process and data integrity combined with simple operation. Laboratory calibration and device pre-maintenance are possible.
Benefits
-
Reliable, long-term stable linear measurement
-
Low maintenance
-
Suitable for CIP/SIP and high-temperature sterilization
-
Unique hygienic design with integrated temperature sensor
-
USP class VI
-
Explosion-proof version, can be used in hazardous areas
Application areas
The Oxymax COS22D can be used for dissolved oxygen measurement in core process stages of many industries:
-
Pharmaceutical and biotechnology sectors
-
– Enzyme production process control
-
– Microbial growth control
-
Food & Beverage
-
Chemical
-
Water treatment
-
– Boiler feedwater
-
– WFI (Water for Injection)
-
Inertizations
-
Residual dissolved oxygen measurement in the process
-
International explosion protection approvals such as ATEX, FM, CSA and NEPSI; digital electrodes can be used in explosion hazardous areas
Spare Parts & Accessories 7
7 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 51505870 | ***COK 21 3 m cable for COS21/COS22Four-core, coaxial with standard connector. | Details |
| 51505868 | ***COK 21 10 m cable for COS 21/COS 22Four-core, coaxial with standard connector. | Details |
| COS22Z- | Dissolved Oxygen Maintenance Kit COS22ZService Kit, COS22, COS22D und COS22E | Enquire |
| 50001041 | DO/Chlorine Sensor Zero-Point Calibration PowderChemical producing water free of oxygen or chlorine for test purposes. | Details |
| 51505872 | Protective cap, autoclavable, COS21/COS22Protective cap for autoclaving COS 21 | Details |
| 50003987 | *** Junction Box VBMwith 10 high-impedance terminals Protection class: IP65 Dimensions: 125 x 80 x 55 mm (L x W x H) | Details |
| COY8- | Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the field | Enquire |
Configurator / Comparison
A
Measuring principle video
Click to playSource: public information from the Endress+Hauser website
Case Studies
Municipal Wastewater Treatment · dissolved oxygen — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring dissolved oxygen for biological processes and deaeration control.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing membrane or optical sensors by basin depth and cleaning method.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing membrane or optical sensors by basin depth and cleaning method, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — blowing follows oxygen demand, cutting aeration power noticeably, with routine maintenance falling noticeably.
Food & Beverage · dissolved oxygen — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from dissolved oxygen, focusing on measuring dissolved oxygen for biological processes and deaeration control.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The dissolved oxygen specification must therefore cover choosing membrane or optical sensors by basin depth and cleaning method.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing membrane or optical sensors by basin depth and cleaning method, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — blowing follows oxygen demand, cutting aeration power noticeably, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · dissolved oxygen — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is dissolved oxygen; the focus is measuring dissolved oxygen for biological processes and deaeration control.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing membrane or optical sensors by basin depth and cleaning method.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing membrane or optical sensors by basin depth and cleaning method, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means blowing follows oxygen demand, cutting aeration power noticeably, which cut the workload on the site maintenance team.
Power & Energy · dissolved oxygen — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on dissolved oxygen and the core task is measuring dissolved oxygen for biological processes and deaeration control.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So dissolved oxygen cannot be specified generically — it calls for choosing membrane or optical sensors by basin depth and cleaning method.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing membrane or optical sensors by basin depth and cleaning method, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is blowing follows oxygen demand, cutting aeration power noticeably.