COS41 Oxymax W

COS41 Oxymax W

Oxymax W COS41

Configurable Models 2 models
Membrane-covered dissolved oxygen sensor is suitable for water, wastewater and utilities. The most economical and practical dissolved oxygen sensor, combined with COM223, is a very cost-effective online dissolved oxygen analyzer. Common model combinations: COS41-2F + COM223-DX0005 or COS41-4F + COM223-DX0005, large stock available!

Product Overview

Oxymax COS41 is a reliable high-precision dissolved oxygen sensor for a wide range of water and wastewater applications. Designed for low maintenance and long service life, the sensor is economical to use. Common models: COS41-2F and COS41-4F AdvantagesHigh measurement accuracyLong maintenance intervalsLow calibration requirements, simple calibration possible in air ApplicationOxymax COS41 is used for dissolved oxygen concentration measurement in the following applications: Wastewater treatment plants:- O2 aeration basin control- Process water treatment and monitoringWaterworks:- Drinking water condition monitoring (oxygen enrichment, corrosion protection, etc.)- River, lake or ocean water quality monitoringUtilities:- O2 biological treatment process control- Process water treatment and monitoringFish ponds:- O2 growth condition optimization control

Spare Parts & Accessories 16

16 spare parts · click to collapse
Order codeDescription
COV45-COS41/COS51x maintenance kit COV45Maintenance parts for Memosens and fixed cable sensors COS51x and COS41. Include membrane caps, o-rings and further maintenance materials.Enquire
71495126COSxx 8.5 mm aperture cage-type dissolved oxygen sensor protective capDetails
71495128Kit COSxx Standard Protective CapDetails
71495130COSxx Dissolved Oxygen Sensor Protective Cap for Fish Farm Aquaculture ApplicationsDetails
COS41-Dissolved oxygen probe COS41Dissolved oxygen sensor, amperometric. 2 electrode cell. Application: Water, waste water. Measuring range: 0.05...20 mg/l. :: Compatibility, Sensor: COS4.Enquire
51506817measuring cable7 m of length, ready made for sensor COS41 with TOP68 connector.Details
51506818measuring cable15 m of length, ready made for sensor COS41 with TOP68 connector.Details
50003987*** Junction Box VBMwith 10 high-impedance terminals Protection class: IP65 Dimensions: 125 x 80 x 55 mm (L x W x H)Details
51506976Set of 2x membrane cap COY31-WP2 pcs. ready made for sensors COS31, COS41 and COS51D standardDetails
51506985Sealing set COY31-OR3 pieces O-rings for sensors COS31, COS41, COS51D and COS71.Details
51506973Polishing foil COY31-PF10 pcs. for cleaning of the gold cathode for sensors COS31, COS41, COS51D and COS71.Details
50053276Protective cage for COS31/41/51D/61/71protection cageDetails
50081787COY 3-SK membrane protective basketfor immersion of diss. oxygen sensors COS31/41/51D/61 in fish ponds.Details
51518599COS31/41/51D/61/71 calibration capCalibration cap, COS31/41/61/71Details
50001041DO/Chlorine Sensor Zero-Point Calibration PowderChemical producing water free of oxygen or chlorine for test purposes.Details
COY8-Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the fieldEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
2 models · click to collapse
All documents for this model
3 documents · click to expand
BA

Operating Instructions Oxymax W COS41 English

30 pages
Preview
TI

覆膜式、双电极、电流式溶解氧测量传感器 Chinese

8 pages
Preview
TI

Technical Information Oxymax W COS41 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · dissolved oxygen — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring dissolved oxygen for biological processes and deaeration control.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing membrane or optical sensors by basin depth and cleaning method.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing membrane or optical sensors by basin depth and cleaning method, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — blowing follows oxygen demand, cutting aeration power noticeably, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · dissolved oxygen — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from dissolved oxygen, focusing on measuring dissolved oxygen for biological processes and deaeration control.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The dissolved oxygen specification must therefore cover choosing membrane or optical sensors by basin depth and cleaning method.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing membrane or optical sensors by basin depth and cleaning method, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — blowing follows oxygen demand, cutting aeration power noticeably, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · dissolved oxygen — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is dissolved oxygen; the focus is measuring dissolved oxygen for biological processes and deaeration control.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing membrane or optical sensors by basin depth and cleaning method.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing membrane or optical sensors by basin depth and cleaning method, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means blowing follows oxygen demand, cutting aeration power noticeably, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · dissolved oxygen — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on dissolved oxygen and the core task is measuring dissolved oxygen for biological processes and deaeration control.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So dissolved oxygen cannot be specified generically — it calls for choosing membrane or optical sensors by basin depth and cleaning method.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing membrane or optical sensors by basin depth and cleaning method, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is blowing follows oxygen demand, cutting aeration power noticeably.