COS61D Oxymax

COS61D Oxymax
Oxymax COS61D
Configurable Models 4 models
Oxymax COS61D is a high-performance, digital oxygen sensor that offers fast, accurate and drift-free measurement. It supports your process with low maintenance, high availability and easy handling. The sensor's long-term stable fluorescence layer is exclusively oxygen-selective (interference-free), ensuring consistently reliable measurement. Thanks to Memosens digital technology, the Oxymax COS61D combines maximum process and data integrity, and facilitates simple lab calibration.
Compare

Oxygen

Measuring Principle Optical oxygen measurement
Application Aeration tank, river monitoring, water treatment, fish farming
Characteristic Digital, optical measurement of dissolved oxygen based on fluorescence quenching
Measurement possible in still water
Measuring range 0 to 20 mg/l
0 to 200 %SAT
0 to 400 hPa
Measuring principle Oxygen-sensitive molecules (marker) are integrated in an optical active layer (fluorescence layer). The fluorescence layer surface is in contact with the medium. The sensor optics are directed at the back of the fluorescence layer. The sensor optics transmit green light pulses to the fluorescence layer. The markers respond (fluoresce) with red light pulses. The duration and intensity of the response signals depend directly on the oxygen contents or partial pressure.
Design Calibration data saved in sensor
High degree of EMC protection
Material Sensor shaft: stainless steel 1.4571
Membrane cap: POM
Dimension Diameter: 40 mm (1.57 inch)
Shaft length: 186 mm (7.32 inch)
Process temperature -5 to 60 °C
(20 to 140 °F)
Process pressure Max. 10 bar abs
(Max. 145 psi)
Temperature sensor NTC 30K
Connection Process connection: G1, NPT 3/4"
Cable connection: fixed cable or TOP68 plug-in-head

The Oxymax COS61D is a high-performance digital dissolved oxygen sensor that provides fast, precise and drift-free measurement, with low maintenance, high suitability and simple operation. The long-term stable fluorescence layer of the sensor is oxygen-selective (interference-free), ensuring always reliable measurement. Using Memosens digital technology, the Oxymax COS61D also offers maximum process and data integrity and is easy to operate. Laboratory calibration and device predictive maintenance are possible.

 

Advantages

Minimum maintenance requirements, maximum suitability

Fast, drift-free measurement for precise aeration control and process monitoring

Long-term stable measurement increases process safety

Optimum measurement performance for various aeration processes (SBR, Anammox, etc.)

No chemical reagents: no electrolyte handling

 

Areas of application

The Oxymax COS61D is used for dissolved oxygen concentration measurement:

 

Wastewater treatment plants:

- O2 aeration basin control

- Process water treatment and monitoring

Waterworks:

- Drinking water status monitoring (oxygen enrichment, corrosion protection, etc.)

- Water quality monitoring of rivers, lakes or seawater

Utilities:

- O2 biological treatment control

- Process water treatment and monitoring

Fish ponds:

- O2 control for optimum growth conditions

Spare Parts & Accessories 16

16 spare parts · click to collapse
Order codeDescription
COV61-COV61 Maintenance kit COS61/COS61xMaintenance parts for COS61/COS61x. Include membrane caps, o-rings and further materials for maintenance.Enquire
51518598Sensor membrane cap, COS61, COS61D, 1 pcSuccessor kit COV61Details
51518597Sealing set, sensor COS61, COS61D, 2 piecesSealing set, Sensor COS61, 2 piecesDetails
71495128Kit COSxx Standard Protective CapDetails
50053276Protective cage for COS31/41/51D/61/71protection cageDetails
71495130COSxx Dissolved Oxygen Sensor Protective Cap for Fish Farm Aquaculture ApplicationsDetails
50081787COY 3-SK membrane protective basketfor immersion of diss. oxygen sensors COS31/41/51D/61 in fish ponds.Details
71495126COSxx 8.5 mm aperture cage-type dissolved oxygen sensor protective capDetails
51518599COS31/41/51D/61/71 calibration capCalibration cap, COS31/41/61/71Details
71110801Cleaning head COS61/61D 6/8mmDetails
71110802Cleaning head COS61/61D 1/4"Details
71072583*** cleaning unit, 230V air compressorDetails
71194623Output Air PurificationDetails
COY8-Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the fieldEnquire
51500832Terminal box RMto lengthen the cable for Memosens/CUS31/41. Protection class IP 65, with 2x Pg 13.5Details
50001041DO/Chlorine Sensor Zero-Point Calibration PowderChemical producing water free of oxygen or chlorine for test purposes.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source:Endress+Hauserwebsite public information

4 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA Oxymax COS61D Chinese

Rev. 1824 44 pages
Preview
BA

BA Oxymax COS61D English

Rev. 1824 44 pages
Preview
BA

COS61D English

Rev. 0113 24 pages
Preview
TI

Oxymax COS61D, COS61 Chinese

Rev. 1621 16 pages
Preview
TI

Oxymax COS61, COS61D Chinese

Rev. 1312 12 pages
Preview
TI

Oxymax COS61D/COS61 English

Rev. 1621 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · dissolved oxygen — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring dissolved oxygen for biological processes and deaeration control.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing membrane or optical sensors by basin depth and cleaning method.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing membrane or optical sensors by basin depth and cleaning method, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — blowing follows oxygen demand, cutting aeration power noticeably, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · dissolved oxygen — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from dissolved oxygen, focusing on measuring dissolved oxygen for biological processes and deaeration control.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The dissolved oxygen specification must therefore cover choosing membrane or optical sensors by basin depth and cleaning method.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing membrane or optical sensors by basin depth and cleaning method, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — blowing follows oxygen demand, cutting aeration power noticeably, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · dissolved oxygen — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is dissolved oxygen; the focus is measuring dissolved oxygen for biological processes and deaeration control.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing membrane or optical sensors by basin depth and cleaning method.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing membrane or optical sensors by basin depth and cleaning method, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means blowing follows oxygen demand, cutting aeration power noticeably, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · dissolved oxygen — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on dissolved oxygen and the core task is measuring dissolved oxygen for biological processes and deaeration control.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So dissolved oxygen cannot be specified generically — it calls for choosing membrane or optical sensors by basin depth and cleaning method.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing membrane or optical sensors by basin depth and cleaning method, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is blowing follows oxygen demand, cutting aeration power noticeably.