COS51E Memosens

COS51E Memosens
Memosens COS51E
Configurable Models 6 models
Memosens COS51E is perfectly suited for all wastewater and utility applications including hazardous areas. The sensor is highly accurate and moisture-resistant ensuring the safety of your processes. COS51E features Memosens 2.0 digital technology. It is able to store more calibration and process data and thus provides the perfect basis for predictive maintenance and IIoT services. Designed to be low-maintenance with a long operating life, the sensor offers outstanding value for money.
Compare

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Typical applications are:
- Wastewater treatment plants: oxygen control in aeration basin, process water treatment and monitoring
.
- Water plants: status monitoring of drinking water, water quality monitoring in rivers, lakes or seas
.
- Utilities of all industries: Oxygen control in biological treatment, process water treatment and monitoring.
Characteristic Digital amperometric 3-electrode longterm-stable sensor to measure dissolved oxygen
Measuring range 0.01 to 100 mg/l
0.00 to 1000 %SAT
0 to 2000 hPa
Material Sensor shaft: POM
Membrane cap: POM
Working electrode: Gold
Counter and reference electrode: silver/silver halide
Membrane: ETFE (COS51-TN), FEP (COS51-TF)
Dimension Diameter: 40mm (1.57 inch)
Shaft length: 146 mm (5.74 inch)
Process temperature -5 to 60 °C
(20 to 140 °F)
Process pressure Max. 5 bar abs
(Max. 72.5 psi abs)
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, JapanEx and INMETRO approval for use in Zone 0, Zone 1 and Zone 2 hazardous areas. With CSA
C/US approval also in Class I Division 1 hazardous areas in the
Gas Ex area. Additionally suitable for Class I Division 2.
Connection Inductive, contactless connection head with Memosens 2.0 technology
Ingress protection IP 68

Applications
The Memosens COS51E is particularly suitable for all kinds of wastewater treatment and utility applications and can measure in hazardous areas. The sensor offers high measurement accuracy; humid environments do not interfere with the measurement results, making the process safer. The COS51E uses Memosens 2.0 digital technology. A large number of calibration and process parameters are stored in the sensor, making it the perfect basis for predictive maintenance and IIoT technology. Low maintenance and long service life make the sensor extremely cost-effective.
The Memosens COS51E dissolved oxygen sensor is suitable for:
Wastewater treatment plants:
- Oxygen input control in aeration basins (O2)
- Process water treatment and monitoring
Utilities:
- O2 control in biological treatment processes
- Process water treatment and monitoring
Waterworks:
- Drinking water condition monitoring (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring of river, lake or sea water
The sensor can measure in hazardous areas (ATEX, FM, CSA).

Benefits
Wide measuring range: membrane-covered measuring principle with cathode design; the sensor is suitable for all kinds of wastewater measurement, including industrial and municipal wastewater treatment plants.
High measurement accuracy: membrane-covered three-electrode design for long-term stable measurement with low drift.
Higher plant availability: Memosens technology combined with the Liquiline transmitter enables plug & play, fast sensor commissioning and replacement.
Non-contact inductive signal transmission for high process safety.
The sensor uses Memosens 2.0 digital technology and stores calibration and process parameters, making it the perfect basis for predictive maintenance and IIoT technology.

 

Spare Parts & Accessories 10

10 spare parts · click to collapse
Order codeDescription
COV45-COS41/COS51x maintenance kit COV45Maintenance parts for Memosens and fixed cable sensors COS51x and COS41. Include membrane caps, o-rings and further maintenance materials.Enquire
COY8-Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the fieldEnquire
71495128Kit COSxx Standard Protective CapDetails
71495126COSxx 8.5 mm aperture cage-type dissolved oxygen sensor protective capDetails
71495130COSxx Dissolved Oxygen Sensor Protective Cap for Fish Farm Aquaculture ApplicationsDetails
71110801Cleaning head COS61/61D 6/8mmDetails
71110802Cleaning head COS61/61D 1/4"Details
51518599COS31/41/51D/61/71 calibration capCalibration cap, COS31/41/61/71Details
71072583*** cleaning unit, 230V air compressorDetails
71194623Output Air PurificationDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

 

A

   

Measurement principle video

Click to play

Source: Endress+Hauserpublic information from the website

6 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Memosens COS51E Chinese

Rev. 0325 44 pages
Preview
BA

BA Memosens COS51E English

Rev. 0325 48 pages
Preview
TI

TI Memosens COS51E Chinese

Rev. 0325 16 pages
Preview
TI

TI Memosens COS51E English

Rev. 0325 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · dissolved oxygen — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring dissolved oxygen for biological processes and deaeration control.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing membrane or optical sensors by basin depth and cleaning method.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing membrane or optical sensors by basin depth and cleaning method, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — blowing follows oxygen demand, cutting aeration power noticeably, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · dissolved oxygen — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from dissolved oxygen, focusing on measuring dissolved oxygen for biological processes and deaeration control.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The dissolved oxygen specification must therefore cover choosing membrane or optical sensors by basin depth and cleaning method.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing membrane or optical sensors by basin depth and cleaning method, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — blowing follows oxygen demand, cutting aeration power noticeably, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · dissolved oxygen — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is dissolved oxygen; the focus is measuring dissolved oxygen for biological processes and deaeration control.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing membrane or optical sensors by basin depth and cleaning method.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing membrane or optical sensors by basin depth and cleaning method, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means blowing follows oxygen demand, cutting aeration power noticeably, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · dissolved oxygen — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on dissolved oxygen and the core task is measuring dissolved oxygen for biological processes and deaeration control.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So dissolved oxygen cannot be specified generically — it calls for choosing membrane or optical sensors by basin depth and cleaning method.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing membrane or optical sensors by basin depth and cleaning method, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is blowing follows oxygen demand, cutting aeration power noticeably.