Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPA140 Dipfit P

CPA140 Dipfit P
Dipfit P CPA140
The Dipfit CPA140 immersion assembly is designed for all demanding applications where aggressive media are involved. With its flange connection, Dipfit is installed safely in the process and offers space for three sensors. Its bayonet lock offers you easy sensor installation even in sticky media or media containing solid particles, thus saving time for maintenance and recalibration.
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Chemical industry, power stations and incinerator plants, metal extraction and metal processing
Installation Immersion assembly
Characteristic Closed tank
Design Bayonet technology, 3 electrode installation locations, 120 mm electrodes, integrated spray cleaning CPR31
Material Immersion tube, sensor holder:
PVDF or stainless steel 1.4404
O-rings: EPDM, VITON, Chemraz or Fluoraz
Dimension Immersion depth: 500 to 2500 mm (19.7 to 98.4 inch), special lengths on request
Process temperature Max. 150 °C (302 °F)
Process pressure Max. 10 bar (145 psi)
Connection Pressurized flange DN80/PN16, ASME 3" lbs150, JIS 10K80A
Certificates, declarations and approvals Material certification 3.1B EN 10204

pH

Measuring Principle Potentiometric
Application Chemical industry, power stations and incinerator plants, metal extraction and metal processing
Installation Immersion assembly
Characteristic Closed tank
Design Bayonet technology, 3 electrode installation locations, 120 mm electrodes, integrated spray cleaning CPR31
Material Immersion tube, sensor holder:
PVDF or stainless steel 1.4404
O-rings: EPDM, VITON, Chemraz or Fluoraz
Dimension Immersion depth: 500 to 2500 mm (19.7 to 98.4 inch), special lengths on request
Process temperature Max. 150 °C (302 °F)
Process pressure Max. 10 bar (145 psi)
Connection Pressurized flange DN80/PN16, ASME 3" lbs150, JIS 10K80A
Certificates, declarations and approvals Material certification 3.1B EN 10204

Product Overview

The Dipfit CPA140 immersion assembly is designed for applications with corrosive media. Using a flange connection, Dipfit is safely installed in the process and provides three sensor mounting positions. The bayonet lock makes sensor installation easy, even in viscous media or media containing solids, saving considerable maintenance and recalibration time.

  • Benefits

  • Bayonet lock mounting for easy installation and removal of the electrode holder

  • Flexible connection to the process via various flanges (DIN, ANSI, JIS)

  • Goretex filter reduces condensation

  • Can accommodate three sensors with a length of 120 mm for pH/ORP or dissolved oxygen measurement as well as a cleaning unit

  • Application

  • Dipfit CPA140 is used for measurement in closed tanks:

  • Chemical industry

  • Petrochemical industry

  • Life sciences

  • Power plants and waste incineration plants

  • Mining, metallurgy and metal processing industries

  • Suitable for applications with pressures up to 10 bar (stainless steel) or 6 bar (PVDF)

Spare Parts & Accessories 42

42 spare parts · click to collapse
Order codeDescription
51500400CXA111/140 CoverDetails
51501131cable glandDetails
51501148CXA140 NPT AdapterDetails
51501150CXA140 FilterDetails
51501183CPA140-30 flanged thermowellDetails
51501184eye boltDetails
51501185flangeDetails
51501187flangeDetails
51501189flangeDetails
51501163bracketDetails
51501164bracketDetails
51501165bracketDetails
51501166bracketDetails
51501167bracketDetails
51501168bracketDetails
51501169bracketDetails
51501170bracketDetails
71161431bracketDetails
71161433bracketDetails
71161434bracketDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
5 documents · click to expand
BA

Dipfit CPA140 操作手册 Chinese

Rev. 1318 32 pages
Preview
BA

Dipfit CPA140 Operating Instructions English

Rev. 1318 32 pages
Preview
BA

Operating Instructions CPA 140 English

16 pages
Preview
TI

Dipfit CPA140 Technical Information English

Rev. 1318 12 pages
Preview
TI

Technical Information CPA 140 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.