Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPA875 Cleanfit

CPA875 Cleanfit
Cleanfit CPA875
Completely sterilizable, the Cleanfit CPA875 retractable assembly guarantees maximum protection from contamination making it ideal for use in life science and food & beverage applications. Fully certified (EHEDG and ASME BPE) and made of FDA-recommended materials, the CPA875 is the right choice where hygiene counts!
Compare

Oxygen

Measuring Principle Sensor ORP / Redox
Application Food and beverages, biotechnology, life sciences, special chemicals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Sterile and hygienic stile
Manual or pneumatic
Material Holder: stainless steel 1.4435
Seals: EPDM-FDA, FKM-FDA, FFKM-FDA
Dimension Immersion depth: 16.1 to 81.4 mm (0.63 to 3.20 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F)
Process pressure Pneumatic drive: 16 bar up to 140 °C (232 psi up to 284 °F)
Manual drive: 8 bar up to 140 °C (116 psi up to 284 °F)
Connection Aseptic DN25 clampable, Aseptic DN50 screw-in, Clamp ISO 2852, ASME BPE, Varivent N

pH

Measuring Principle Potentiometric
Application Food and beverages, biotechnology, life sciences, special chemicals
Installation Retractable process assembly
Characteristic Open and closed tanks, piping
Design Sterile and hygienic stile
Manual or pneumatic
Material Holder: stainless steel 1.4435
Seals: EPDM-FDA, FKM-FDA, FFKM-FDA
Dimension Immersion depth: 16.1 to 81.4 mm (0.63 to 3.20 inch), depending on process adaption
Process temperature -10 to 140 °C (14 to 284 °F)
Process pressure Pneumatic drive: 16 bar up to 140 °C (232 psi up to 284 °F)
Manual drive: 8 bar up to 140 °C (116 psi up to 284 °F)
Connection Aseptic DN25 clampable, Aseptic DN50 screw-in, Clamp ISO 2852, ASME BPE, Varivent N

Completely sterile, the Cleanfit CPA875 retractable assembly ensures the highest contamination protection, making it the ideal choice for life sciences, food and beverage applications. With all approvals (EHEDG and ASME BPE) and FDA-listed materials, the CPA875 is the right choice for hygienic applications!

  • Benefits

  • Highest process safety: the patented dynamic seal design prevents contamination.

  • Simple operation: sensor removal, sterilization and calibration in the process – corrosion-resistant and hygienically safe.

  • No cross-contamination: sterile design complies with EHEDG and ASME BPE, and the sealing system complies with FDA and USP Cl. VI.

  • Flexible: various process connections to meet diverse process connection requirements.

  • Optional double service chamber: the seal between sterile and non-sterile parts moves dynamically along the sensor tube – like a syringe. The sterile space and the process medium never come into contact.

  • Application areas

  • The Cleanfit CPA875 is a retractable assembly for installing pH electrodes, ORP electrodes, dissolved oxygen sensors and NIR sensors with a diameter of 12 mm and lengths of 225/360 mm.

Its design offers the highest safety in the following industries:

  • Food and Beverage

  • Biotechnology

  • Life sciences

  • Specialty chemicals

Spare Parts & Accessories 1

1 spare parts · click to collapse
Order codeDescription
XPC0001-CPA875 Maintenance KitAccessories, spare parts and maintenance kits for retractable process assembly Cleanfit CPA875 Content: All selectable spare parts, sealing sets incl. certificates and approvals as well as accessoriesEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: public information from the Endress+Hauser website

All documents for this model
4 documents · click to expand
BA

BA Cleanfit CPA875 Chinese

Rev. 0626 72 pages
Preview
BA

BA Cleanfit CPA875 English

Rev. 0626 72 pages
Preview
TI

TI Cleanfit CPA875 Chinese

Rev. 0524 32 pages
Preview
TI

TI Cleanfit CPA875 English

Rev. 0524 32 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.