Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CYA112 FLEXDIP

CYA112 FLEXDIP
FLEXDIP CYA112
Configurable Models 3 models
The Flexdip CYA112 is a modular assembly for sensor immersion in open basins, channels, or tanks. It allows nearly any kind of sensor mounting – chain, fixed, or free-swinging – and features a quick fastener for rapid and safe installation of Memosens or fixed-cable sensors. The assembly provides you with outstanding flexibility and enables you to optimally configure your measurement at low costs.
Compare

Analyser

Measuring Principle UV photometric
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Process temperature 0 to 60 °C (32 to 140 °F)
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels

Conductivity

Measuring Principle Conductive
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Material Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension Tauchrohr Durchmesser: 40 mm (1.57 Zoll)
Länge: 600, 1200, 1800 und 2400 mm
(23.6, 47.2, 70.9 und 94.5 Zoll)
Process temperature 0 ... 60 °C (32 ... 140 °F)

Disinfection

Measuring Principle Total chlorine
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Material Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature 0 to 60 °C (32 to 140 °F)

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Material Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature 0 to 60 °C (32 to 140 °F)

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Material Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature 0 to 60 °C (32 to 140 °F)

Turbidity

Measuring Principle Single beam scattered light
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Material Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature 0 to 60 °C (32 to 140 °F)

pH

Measuring Principle Potentiometric
Application Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic Simple and easy installation
Universal and flexible
Design Versions in stainless steel or PVC
Material Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature 0 to 60 °C (32 to 140 °F)

The Flexdip CYA112 is a modular holder for installing sensors in open basins, channels and tanks. It allows the installation of almost all types of sensors, including chain, fixed and freely swinging versions. Faster and safer installation is possible for Memosens and fixed cable sensors. The holder offers excellent flexibility and enables cost-effective, optimum configuration of the entire measuring point.

Benefits

  • Modular design for optimum configuration of each measuring point

  • Non-contact plug-in Memosens sensors for fast installation and replacement

  • No tangling when installing sensors with integrated cables

  • Simple installation and maintenance

  • Robust design: suitable for process pressures up to 6 bar (87 psi)

Applications

  • The Flexdip CYH112 holder is suitable for measurements in open basins, channels and tanks:

  • Wastewater treatment plants

  • Waterworks

  • Utilities

  • With the Flexdip CYA112 holder, a perfect measuring system is created and sensors can be easily isolated.

  • The Flexdip measuring system can measure the following parameters:

  • pH/ORP

  • Conductivity

  • Dissolved oxygen

  • Turbidity

  • Sludge level

  • Disinfection

  • UV photometry

  • Nutrients

Spare Parts & Accessories 27

27 spare parts · click to collapse
Order codeDescription
50014496floatOld Material-Number: 116591Details
71190891floatDetails
71096714CYA112:Bracket chainDetails
71096704CYA112: Rubber PlugDetails
71372026CYA112 adapter kit CCS5x + CCS5xDDetails
71094033CYA112 accessory, O-ring for quick fasteningDetails
71094034CYA112, O-ring for immersion tubeDetails
71092049Multifunctional Clamping Ring CYA112CYH112Details
71092054immersion rod trayto be used with long immersion pipesDetails
71092052Triangular hook (chain clamp), CYA112protection for chain holderDetails
71092051Velco cable gland for 4 electrode wires4 pieces, for sensor cableDetails
71093382Mounting accessoriesDetails
71093383Mounting accessoriesDetails
71093384Mounting accessoriesfor pH-electrodes 12mm, 120mm lengthDetails
71093377Mounting accessoriesfast sensor assemblyDetails
71093438Mounting accessoriesDetails
71073768Pipe D=40mm, L=150mm, V4A M36/G1 inch.Details
71073769tube*Details
71073770Pipe D=40 mm, W=90°, V4A, M36/G1 inch.Details
71073767tube.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: Endress+Hauserpublic information from the website

3 models · click to collapse
All documents for this model
7 documents · click to expand
BA

Flexdip CYA112 Chinese

Rev. 1419 36 pages
Preview
BA

Flexdip CYA112 English

Rev. 1419 36 pages
Preview
BA

Operating Instructions, Flexdip CYA112 English

Rev. 0409 20 pages
Preview
TI

Flexdip CYA112 Chinese

Rev. 1419 24 pages
Preview
TI

技术资料 Flexdip CYA112 Chinese

Rev. 1312 24 pages
Preview
TI

Flexdip CYA112 English

Rev. 1419 24 pages
Preview
TI

Technical Information, Flexdip CYA112 English

Rev. 0409 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.