Endress+Hauser CPA472D
The Cleanfit CPA472D assembly is designed for harsh process conditions. It offers a great variety of rugged materials to operate your sensors safely even under high pressure, high temperature or in aggressive media. The assembly allows you to replace sensors without interrupting the process or to clean and calibrate them automatically via the optional control system. Benefit from easy, time-saving sensor handling and an extended operating life of the sensors.
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
Installation Retractable holder
Characteristic For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar
Design Manual or pneumatical
Material Electrode holder, rinse chamber and raised face:
PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)
Dimension Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
Process temperature 0 to 140 °C (32 to 284 °F)
Process pressure 0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation
Connection Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

pH

Measuring Principle Potentiometric
Application Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
Installation Retractable holder
Characteristic For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar
Design Manual or pneumatical
Material Electrode holder, rinse chamber and raised face:
PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)
Dimension Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
Process temperature 0 to 140 °C (32 to 284 °F)
Process pressure 0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation
Connection Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

Product Overview

The Cleanfit CPA472D retractable assembly is designed for use under demanding conditions. It is available in various rugged materials, allowing sensors to be operated safely even in high-pressure, high-temperature and corrosive media. Optional control systems allow automatic sensor cleaning and calibration without interrupting the process. Simple, time-saving sensor operation extends sensor service life.

  • Benefits

  • Rugged: suitable for applications with pressures up to 10 bar and temperatures up to 140 °C; available in PEEK, PVDF and conductive PVDF versions

  • Excellent chemical resistance ensures a long service life

  • Electrode cleaning and calibration without process interruption - saves maintenance time and operating costs

  • Various materials and process connections available for flexible use in all measuring applications

  • Application areas

  • The Cleanfit CPA472D can be used for tank or pipe installation:

  • Chemical industry

  • Power plants

  • Biomass-to-oil plants

  • For applications with pressures up to 10 bar

Spare Parts & Accessories 135

135 spare parts · click to collapse
Order codeDescription
71024454O-ringFor armatur CPA472...Details
71211749CPA472D Flange Inner Seal, KalrezDetails
71211751CPA472D Viton flange sealDetails
71211752CPA472D flange seal EPDMDetails
71211736CPA472D seal G1 1/4" inside EPDMDetails
71211745CPA472D Seal G1 1/4" inside KalrezDetails
71211748CPA472D seal G1 1/4 inside KalrezDetails
XPC0003-XPA871: Accessories for CPA871 bracketAccessories, spare parts and maintenance kits for retractable process assembly Cleanfit CPA871Enquire
71024242sealing flangeCorrosion-resistant o-rings for CPA472D, outside sealed; Viton, FPMDetails
71027299CPA472D Viton Seal Ring Setfor G1 1/4" adapterDetails
71024247sealing flangeCorrosion-resistant o-rings for CPA472D,Outside sealed,Perfluorlast; KalrezDetails
71027302CPA472D Kalrez seal ring setfor G1 1/4" adapterDetails
71043257sealing flangeDetails
71043259Sealing deviceDetails
71090063O-ringDetails
71090065O-ringDetails
71214026CPA472D rinse chamberfor internal process sealing with rinsing connection G1/4" for process connection G1 1/4"Details
71214033CPA472D rinse chamberfor internal process sealing with rinsing connection G1/4" for process connection G1 1/4"Details
71214227CPA472D rinse chamberfor internal process sealing with rinsing connection NPT1/4" for process connection G1 1/4"Details
71214228CPA472D rinse chamberfor internal process sealing with rinsing connection NPT1/4" for process connection G1 1/4"Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: public information from the Endress+Hauser website

All documents for this model
8 documents · click to expand
BA

Operating Instructions Cleanfit CPA472D English

Rev. 1313 44 pages
Preview
BA

Operating Instructions Cleanfit P CPA472D English

Rev. 0910 44 pages
Preview
TI

技术资料 Cleanfit CPA472D Chinese

Rev. 1313 20 pages
Preview
TI

技术资料 Cleanfit CPA472D Chinese

Rev. 0610 16 pages
Preview
TI

Technical Information Topcal S CPC310 English

Rev. 1315 32 pages
Preview
TI

Technical Information Cleanfit P CPA472D English

Rev. 1313 20 pages
Preview
TI

Technical Information Cleanfit P CPA472D English

Rev. 0610 16 pages
Preview
TI

Technical Information Topcal S CPC310 English

32 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.