Technical Data
CompareTurbidity
| Measuring Principle | Single beam scattered light |
| Application | Flow-assembly for potable water applications and distribution networks flow-assembly for process water applications to be integrate in the plant / skid |
| Installation | Flow-assembly for potable water applications and distribution networks flow-assembly for process water applications to be integrate in the plant / skid |
| Design | Stainless steel flow-assembly, 100mm OD, 2mm Wall thickness, 1.4404 |
| Material | Stainless steel1.4404 |
| Dimension | 200 x 164mm |
| Process temperature | 0 .. 85°C |
| Process pressure | 0 .. 10 bars |
| Connection | Welding socket |
The Flowfit CUA262 is a flow-through holder for turbidity measurement, suitable for all drinking water and process water applications. Its hygienic design allows it to be welded directly onto skids, pipes or plant equipment – no bypass installation required. The robust stainless steel withstands high pressure and high temperature, making it fully suitable for drinking water measurement. Thus, every drop of water in the process can be saved. Convenient connection and automatic venting accelerate sensor installation and commissioning.
Benefits
Turbidity measurement without medium loss: hygienic inline measurement saves every drop of water in the process.
No bypass installation required: the hygienic design allows direct welding onto pipes, skids or plant equipment.
Compact design: small footprint saves installation space on skids.
Fast sensor installation and commissioning: convenient connection and automatic venting accelerate integration into the process.
Robust construction: for applications with a maximum process pressure of 6 bar (87 psi) and a maximum temperature of 85°C (185°F).
Applications
The Flowfit CUA262 is a flow-through holder for welding onto skids, pipes or plant equipment. Used together with the Turbimax CUS52D sensor:
Drinking water and process water:
- All measuring points from the inlet to the outlet of the waterworks
- Extraction and raw water control
- All quality control points in water production
Wastewater treatment plants:
- Reuse of outlet water
Utilities in all industries:
- All measuring points from inlet to outlet in water production
- All measuring points of the water network
Spare Parts & Accessories 2
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Measuring principle video
Click to playManuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · turbidity — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.
Food & Beverage · turbidity — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.
Chemical & Pharmaceutical · turbidity — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.
Power & Energy · turbidity — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserTurbimax CUS52D
Endress+HauserTurbimax CUS51D
Endress+HauserTurbimax CUS71D
Endress+HauserTurbimax CUS50D
Endress+HauserTurbimax CUE22, compact white light
Endress+HauserTurbimax CUE21, compact infrared
Endress+HauserFlowfit CUA252
Endress+Hauser