Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CUA262 Flowfit

CUA262 Flowfit
Flowfit CUA262
Flowfit CUA262 is a turbidity flow assembly for all drinking and process water applications. Its hygienic design allows direct welding in your skid, your pipeline or your plant – no more need for bypass installations. The ruggedized stainless steel material withstands high pressure and temperature and is fully suitable for drinking water. Thus, you preserve each drop of water in the process. Its easy to use Clamp connection and automatic venting speed up sensor installation and commissioning.
Compare

Turbidity

Measuring Principle Single beam scattered light
Application Flow-assembly for potable water
applications
and distribution networks
flow-assembly for process water
applications
to be integrate in the plant / skid
Installation Flow-assembly for potable water
applications
and distribution networks
flow-assembly for process water
applications
to be integrate in the plant / skid
Design Stainless steel flow-assembly, 100mm OD, 2mm
Wall thickness, 1.4404
Material Stainless steel1.4404
Dimension 200 x 164mm
Process temperature 0 .. 85°C
Process pressure 0 .. 10 bars
Connection Welding socket

The Flowfit CUA262 is a flow-through holder for turbidity measurement, suitable for all drinking water and process water applications. Its hygienic design allows it to be welded directly onto skids, pipes or plant equipment – no bypass installation required. The robust stainless steel withstands high pressure and high temperature, making it fully suitable for drinking water measurement. Thus, every drop of water in the process can be saved. Convenient connection and automatic venting accelerate sensor installation and commissioning.

Benefits
Turbidity measurement without medium loss: hygienic inline measurement saves every drop of water in the process.
No bypass installation required: the hygienic design allows direct welding onto pipes, skids or plant equipment.
Compact design: small footprint saves installation space on skids.
Fast sensor installation and commissioning: convenient connection and automatic venting accelerate integration into the process.
Robust construction: for applications with a maximum process pressure of 6 bar (87 psi) and a maximum temperature of 85°C (185°F).

Applications
The Flowfit CUA262 is a flow-through holder for welding onto skids, pipes or plant equipment. Used together with the Turbimax CUS52D sensor:
Drinking water and process water:
- All measuring points from the inlet to the outlet of the waterworks
- Extraction and raw water control
- All quality control points in water production
Wastewater treatment plants:
- Reuse of outlet water
Utilities in all industries:
- All measuring points from inlet to outlet in water production
- All measuring points of the water network

 

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
71241882CUS52D: 2x chuck sealFor CUS50D, CUS52D, CUA252 and CUA262Details
71242180blind coverFor CUS50D, CUS52D, CUA252 and CUA262Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

Flowfit CUA262 Chinese

Rev. 0219 24 pages
Preview
BA

Flowfit CUA262 English

Rev. 0219 24 pages
Preview
TI

CUA262 Chinese

Rev. 0219 8 pages
Preview
TI

CUA262 English

Rev. 0219 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · turbidity — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.

Food & Beverage

Food & Beverage · turbidity — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · turbidity — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · turbidity — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.