Turbimax CUE22 is a reliable turbidity meter for continuous measurement compliant to US EPA 180.1. Operation is simple: connect the water, adjust the settings and the system runs unattended. Turbimax CUE22 provides guided calibration according to predefined standards, helping to streamline maintenance. Its automatic ultrasonic cleaning function extends service intervals offering significant savings in operational expenditure.
Compare

Turbidity

Measuring Principle
Application Online continuous monitoring of clean water :
- Drinking water
- Treated process water
Installation Compact device for bypass-installations.
Characteristic " Versions with white light source
" Fast and easy calibration
" Complete primary calibration in less than 5 minutes
" Verification in seconds
" Reduced calibration costs and quick response times thanks to low volume sample chamber
" Automatic continuous ultrasonic cleaning (Autoclean)increases cleaning intervals dramatically
" Simple modular design
" Easy to use and service
" Affordable thanks to modular microprocessor based technology
" Digital high-speed connections through RS-485 with Modbus
Optional Features:
" Flow chamber for bubble suppression
" Reusable calibration kit
Measuring range 0 - 100 NTU
Measuring principle Turbidity measurement using standardised 90° scattered light method acc. to U.S.EPA180.1 (White Light)
Design The transmitted white light beam is scattered by the solid matter particles in the medium. The scattered light beams are detected by scattered light receivers which are arranged at an angle of 90° to the white light source.
Material Housing: ABS
Flow-through head: Nylon
Sample cuvette: Borosilicate glass
Sample cuvette seal: Silicone
Flow-through fittings: Polypropylene
Flow-through lock down pins: Stainless steel (AISI 304 or AISI 303)
Inlet tube: Stainless steel (AISI 316)
Dimension 347,16 x 207,65 x 196,85 mm
(13.66 x 8.17 x 7.75 inches)
Process temperature 1°C - 50°C
(34 - 122°F)
Process pressure max. 13.78 bar / 200 psicontrolled by integral pressure regulator
Ingress protection IP66
Output / communication 4-20mA, galvanic isolated
Bi-directional RS-485, Modbus optional.

Product Overview

The Turbimax CUE22 is a reliable turbidity meter for continuous water turbidity measurement compliant with US EPA 180.1. It is easy to operate: connect the water source, set the parameters and the system runs automatically. The Turbimax CUE22 provides calibration guidance according to preset standards, effectively improving maintenance efficiency. Its automatic ultrasonic cleaning function extends maintenance intervals and saves significant operating costs.

  • Advantages

  • Extended maintenance intervals and reduced operating costs

  • Fast and simple calibration, verification within seconds

  • The low-volume sampling chamber reduces calibration costs and speeds up response time

  • The automatic ultrasonic cleaning function reduces maintenance workload

  • Sampling condition adjustment (including flow and pressure)

  • Areas of application

  • The Turbimax CUE22 online turbidity meter can be used for:

  • Drinking water and process water measurement:

  • Process monitoring 

  • Filter monitoring and filter backwash monitoring in waterworks 

  • Water quality monitoring in waterworks and supply networks

  • Utilities:

  • Return lines

  • Cooling water monitoring

  • The Turbimax CUE22 measures in compliance with US EPA 180.1.

Spare Parts & Accessories 10

10 spare parts · click to collapse
Order codeDescription
71030104CUE22 Electronic ModuleLight source: White light Measuring range: 0 - 100 NTU Spare part turbidity measurementDetails
71030105Field junction box CUE21/CUE22Supply voltage: 100-240 VAC Spare part turbidity measurementDetails
51518578Desiccant for CUE21/CUE22Refill pack Accessory turbidity measurementDetails
51518579Pipe fittings for CUE21/CUE22Accessory turbidity measurementDetails
51518576Ultrasonic cleaning glass tube for CUE21/CUE22Accessory turbidity measurementDetails
71030102CUE22 calibration fluidReady for use solutions: 0,02 NTU, 10 NTU and 100 NTU. Accessory turbidity measurementDetails
51518575Flow-through chamber for CUE21/CUE22for bubble suppression Accessory turbidity measurementDetails
71085512*** Pressure Regulator CUE21/22Details
71267830O-ringDetails
71267825*** Flow Cell Flow RegulatorDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

2 models · click to collapse
All documents for this model
2 documents · click to expand
BA

Operating Instructions Turbimax CUE21 / CUE22 English

40 pages
Preview
TI

Technical Information Turbimax CUE21 / CUE22 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · turbidity — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.

Food & Beverage

Food & Beverage · turbidity — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · turbidity — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · turbidity — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.