Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CUS71D Turbimax

CUS71D Turbimax
Turbimax CUS71D
Configurable Models 4 models
Turbimax CUS71D continuously monitors the separation and transition zones in clarification and settling tanks, ensuring safe, economic and efficient sedimentation processes. It provides you with reliable, real-time measured values in real-time for quick control of valves and actuators. Turbimax CUS71D is ideal sensor for every measuring task - from protection of downstream water in wastewater treatment plants to optimization of backwash times in waterworks.
Compare

Sludge Level

Measuring Principle Ultrasonic sensor
Application Continious interface measurement in sedimentation basins
Installation Submerged sensor with fixed cable
Measuring range 0.3 to 10 m (1 to 32 ft)
Measuring principle Ultrasonic return-time measurement
Material Sensor: ABS and epoxy resin
Wiper: EPDM
Housing: Polyamide
Dimension Diameter: 74 mm(2.9 inch)
Lenght standard sensor: 68 mm (2.7 inch)
Lenght wiper sensor: 135 mm (5.3 inch)
Process temperature 1 to 50 °C (34 to 122 °F)
Process pressure Standard version: 0 to 6 bar (0 to 87 psi)
Version with wiper: 0 to 0.3 bar (0 to 4.4 psi)
Temperature sensor -
Ex certification None
Connection Process connection: G1 and NPT 3/4"
Fixed cable 15 m
Ingress protection IP68
Output / communication Digital output for connection to Liquiline CM44x
Certificates, declarations and approvals EAC

The Turbimax CUS71D continuously monitors the separation and transition zones in clarifiers and sedimentation basins, completing the sedimentation process safely, economically and efficiently. It provides reliable real-time measured values, ensuring fast control of valves and actuators. The Turbimax CUS71D is the ideal sensor for various measuring tasks, protecting the downstream water quality of wastewater treatment plants and optimizing the backwashing time of waterworks.

 

Advantages

Reliable: the sensor provides precise continuous measurement of sludge level or range

Safe: real-time measured values ensure fast control of valves and actuators

Simple: the sensor is pre-calibrated for easy commissioning

Cost-saving: automatic wiper cleaning enables long-term maintenance-free operation

Intelligent sensor: all characteristic parameter values and calibration parameter values are stored in the sensor

Flexible: two different sensor types to choose from, meeting the requirements of various measuring tasks

 

Areas of application

The Turbimax CUS71D is an online sludge measuring sensor suitable for:

 

Wastewater treatment plants:

- Sedimentation measurement of solids

Drinking and process water treatment:

- Sedimentation measurement of solids

- Filter monitoring and backwashing

- Level measurement in marble chip tanks

Utilities of all industries:

- Static separation processes

- Reuse of process water

- Product separation

- Flotation processes

Spare Parts & Accessories 6

6 spare parts · click to collapse
Order codeDescription
71156817CUY31 wiperContent: 2x Wiper blade complete Usage: CUS71D with wiperDetails
71156830CUS71D Wiper: MotorContent: Motor for wiper, complete Usage: CUS71D with wiperDetails
71156832CUS71D wiper couplingContent: 2 x coupling for wiper motor Usage: CUS71D with wiperDetails
71156833CUS71D Wiper: PistonContent: 1x wiper shaft with bearing Usage: CUS71D with wiperDetails
71311408Kit CUS71D: Sensor protection, PVCContent: 1 x Sensor protection Usage: CUS71D without wiper Successor is 71404869Details
71404869Kit CUS71D sensor protection v. 2Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

A

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
4 models · click to collapse
All documents for this model
9 documents · click to expand
BA

操作手册 Turbimax CUS71D Chinese

Rev. 0415 40 pages
Preview
BA

操作手册 Turbimax CUS71D Chinese

Rev. 0211 32 pages
Preview
BA

Turbimax CUS71D Operating Instructions English

Rev. 0618 32 pages
Preview
BA

Operating Instructions Turbimax CUS71D English

Rev. 0211 32 pages
Preview
TI

技术资料 Turbimax CUS71D Chinese

Rev. 0415 12 pages
Preview
TI

技术资料 Turbimax CUS71D Chinese

Rev. 0312 12 pages
Preview
TI

超声波污泥界面传感器 Chinese

Rev. 0211 12 pages
Preview
TI

Turbimax CUS71D Technical Information English

Rev. 0518 12 pages
Preview
TI

Technical Information Turbimax CUS71D English

Rev. 0211 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · turbidity — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.

Food & Beverage

Food & Beverage · turbidity — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · turbidity — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · turbidity — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.