Technical Data
CompareSludge Level
| Measuring Principle | Ultrasonic sensor |
| Application | Continious interface measurement in sedimentation basins |
| Installation | Submerged sensor with fixed cable |
| Measuring range | 0.3 to 10 m (1 to 32 ft) |
| Measuring principle | Ultrasonic return-time measurement |
| Material | Sensor: ABS and epoxy resin Wiper: EPDM Housing: Polyamide |
| Dimension | Diameter: 74 mm(2.9 inch) Lenght standard sensor: 68 mm (2.7 inch) Lenght wiper sensor: 135 mm (5.3 inch) |
| Process temperature | 1 to 50 °C (34 to 122 °F) |
| Process pressure | Standard version: 0 to 6 bar (0 to 87 psi) Version with wiper: 0 to 0.3 bar (0 to 4.4 psi) |
| Temperature sensor | - |
| Ex certification | None |
| Connection | Process connection: G1 and NPT 3/4" Fixed cable 15 m |
| Ingress protection | IP68 |
| Output / communication | Digital output for connection to Liquiline CM44x |
| Certificates, declarations and approvals | EAC |
The Turbimax CUS71D continuously monitors the separation and transition zones in clarifiers and sedimentation basins, completing the sedimentation process safely, economically and efficiently. It provides reliable real-time measured values, ensuring fast control of valves and actuators. The Turbimax CUS71D is the ideal sensor for various measuring tasks, protecting the downstream water quality of wastewater treatment plants and optimizing the backwashing time of waterworks.
Advantages
Reliable: the sensor provides precise continuous measurement of sludge level or range
Safe: real-time measured values ensure fast control of valves and actuators
Simple: the sensor is pre-calibrated for easy commissioning
Cost-saving: automatic wiper cleaning enables long-term maintenance-free operation
Intelligent sensor: all characteristic parameter values and calibration parameter values are stored in the sensor
Flexible: two different sensor types to choose from, meeting the requirements of various measuring tasks
Areas of application
The Turbimax CUS71D is an online sludge measuring sensor suitable for:
Wastewater treatment plants:
- Sedimentation measurement of solids
Drinking and process water treatment:
- Sedimentation measurement of solids
- Filter monitoring and backwashing
- Level measurement in marble chip tanks
Utilities of all industries:
- Static separation processes
- Reuse of process water
- Product separation
- Flotation processes
Spare Parts & Accessories 6
6 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71156817 | CUY31 wiperContent: 2x Wiper blade complete Usage: CUS71D with wiper | Details |
| 71156830 | CUS71D Wiper: MotorContent: Motor for wiper, complete Usage: CUS71D with wiper | Details |
| 71156832 | CUS71D wiper couplingContent: 2 x coupling for wiper motor Usage: CUS71D with wiper | Details |
| 71156833 | CUS71D Wiper: PistonContent: 1x wiper shaft with bearing Usage: CUS71D with wiper | Details |
| 71311408 | Kit CUS71D: Sensor protection, PVCContent: 1 x Sensor protection Usage: CUS71D without wiper Successor is 71404869 | Details |
| 71404869 | Kit CUS71D sensor protection v. 2 | Details |
Configurator / Comparison
A
A
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playManuals & Documents 9
All documents for this model9 documents · click to expand
操作手册 Turbimax CUS71D Chinese
操作手册 Turbimax CUS71D Chinese
Turbimax CUS71D Operating Instructions English
Operating Instructions Turbimax CUS71D English
技术资料 Turbimax CUS71D Chinese
技术资料 Turbimax CUS71D Chinese
超声波污泥界面传感器 Chinese
Turbimax CUS71D Technical Information English
Technical Information Turbimax CUS71D English
Case Studies
Municipal Wastewater Treatment · turbidity — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.
Food & Beverage · turbidity — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.
Chemical & Pharmaceutical · turbidity — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.
Power & Energy · turbidity — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.