Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CYA251 Flowfit

CYA251 Flowfit
Flowfit CYA251
Configurable Models 1 models
Flowfit CYA251 is a flow assembly for nitrate/SAC, turbidity and oxygen sensors with a diameter of 40mm. It allows optimum adaption to your piping system thanks to numerous available process connections. The ruggedized material withstands even aggressive media and harsh environmental conditions and a back-pressure valve protects your process from blowing out and increases operational safety. Better still, with the automatic cleaning nozzle, you'll benefit from extended maintenance intervals.
Compare

Analyser

Measuring Principle UV photometric

Oxygen

Measuring Principle Amperometric oxygen measurement

Turbidity

Measuring Principle Single beam scattered light

The Flowfit CYA251 is a flow-through holder, 40 mm in diameter, for nitrate, turbidity and oxygen measuring sensors. Thanks to the large number of available process connections, it is highly suitable for pipe systems. Even in corrosive media and harsh environments, the reinforced material and the back-pressure valve protect the measuring process from shutdown and increase operational safety. Even better, the automatic cleaning nozzle extends maintenance intervals.

Benefits

  • Conveniently adaptable to your system: process connections for pipes of various diameters

  • Various installation options: for pipe mounting or wall mounting

  • Fast measurement: small internal volume shortens sensor response time

  • Simple and safe maintenance: automatic sensor cleaning without interrupting the process

  • Robust construction: process pressure up to 6 bar (87 psi)

Applications

The Flowfit CYA251 is a universal flow holder for:

  • Wastewater treatment plants:

  • Process water treatment and monitoring

  • Wastewater quality monitoring

  • Drinking water and process water

  • Process water treatment and monitoring

  • Filter monitoring and filter backwash

Utilities:

  • Process water treatment and monitoring

  • Cooling water monitoring

Suitable for:

  • Nitrate/SAC: various measuring ranges

  • Dissolved oxygen: various measuring ranges

  • Turbidity: medium and high measuring ranges

Spare Parts & Accessories 20

20 spare parts · click to collapse
Order codeDescription
71162868CYA251: WasherDetails
71162872CYA251: Insulating PlugDetails
71144328spray nozzleflowcell CYA251Details
71144330spray nozzleflowcell CYA251Details
71144331spray nozzleflowcell CYA251Details
71144332spray nozzle CUS31D/CUS41flowcell CYA251Details
71424819Spray nozzle kit CUS50DDetails
71144333Sensor adapterflowcell CYA251Details
71144334Sensor adapterDetails
71144335Sensor adapterflowcell CYA251Details
71144336Sensor adapter: CUS31, CUS41flowcell CYA251Details
71420151Kit CYA251 sensor adapter CUS50DDetails
71144337Sensor adapterflowcell CYA251Details
71144338Sensor adapterflowcell CYA251Details
71248647Sensor adapterDetails
71144340Sensor adapterflowcell CYA251Details
71475982CAS80E mounting adapter for CYA251 flow cellDetails
71144369Outdoor wall-mount componentDetails
71448687Kit of 10 hexagonal nuts G1"Details
71540933Kit CYA251 blind cover assemblyDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: Endress+Hauserpublic information from the website

1 models · click to collapse
All documents for this model
6 documents · click to expand
BA

CYA251 操作手册 Chinese

Rev. 0318 32 pages
Preview
BA

Flowfit CYA251 English

Rev. 0420 44 pages
Preview
TI

CYA251 Chinese

Rev. 0420 12 pages
Preview
TI

技术资料 Flowfit CYA251 Chinese

Rev. 0212 12 pages
Preview
TI

CYA251 English

Rev. 0420 12 pages
Preview
TI

Technical Information Flowfit CYA251 English

Rev. 0112 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.