Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CYA680 Flow assembly

CYA680 Flow assembly
Flow assembly CYA680
The CYA680 flow assembly is the simple solution for pH and conductivity measurement in pipelines of hygienic and sterile applications. It is designed for inline cleaning and sterilization and perfectly suited for small pipe diameters, offering maximum safety for your high-quality products. For perfect performance in aggressive and corrosive media, CYA680 is available as PVDF version.
Compare

Conductivity

Measuring Principle Conductive
Characteristic Life Sciences, Oil & Gas, Chemical Industries
Design flow assembly with small bore from 5mm ... 45mm corresponding the Clamp Diameters
for mounting 1Memosens CLS82D and or 1 pH electrode (CPS71D-TU)
Material Holder: stainless steel or PVDF
Sealings: EPDM, Kalrez, Viton, Teflon-coated Viton (all FDA compliant)
Dimension flange spacing 82,55 mm, 3;25
Process temperature max.130°C
266°F
Process pressure Stainless steel: max. 16 bar; PVDF: max 4 bar
Connection Clamp 0,25" ... 2"
Certificates, declarations and approvals Material certification 3.1 EN 10204
Surface roughness Ra < 0.38 µm.

pH

Measuring Principle Potentiometric
Application Life Sciences, Oil & Gas, Chemical Industries
Installation flow assembly,with Clamp 0,25" ... 2"
Characteristic pipe mounting
Design flow assembly with small bore from 5mm ... 45mm corresponding the Clamp Diameters
for mounting 1 pH electrode (CPS71D-TU) and 1Memosens CLS82D
Material Holder: stainless steel or PVDF
Sealings: EPDM, Kalrez, Viton, Teflon-coated Viton (all FDA compliant)
Dimension flange spacing 82,55 mm, 3;25"
Process temperature max.130°C
266°F
Process pressure Stainless steel: max. 16 bar; PVDF: max 4 bar
Connection Clamp 0,25" ... 2"
Certificates, declarations and approvals Material certification 3.1 EN 10204
Surface roughness Ra < 0.38 µm.

Flow assembly
CYA680
Assembly for the life sciences and chemical industries
Benefits
Fast measured values with low volume optimize product yield

  • High product safety: assembly suitable for cleaning in place (CIP) and sterilization in place (SIP)

  • Compliance with strict life sciences regulations: biocompatibility certified according to USP Class VI, FDA-certified seals and hygienic electropolished surface Ra=0.38 μm (15 μinch)

Even suitable for corrosive media with the PVDF version
Application areas
The CYA680 flow assembly is a simple solution for pH and conductivity measurement in pipelines of hygienic and sterile applications. It is designed for in-line cleaning and sterilization, ideally suited to small-diameter pipelines, providing maximum safety for your high-quality product. For perfect performance in corrosive and aggressive media, the CYA680 is available in a PVDF version.

  • The CYA680 flow assembly is used in combination with 12 mm sensors, e.g.

  • pH measurement

  • Conductivity measurement

Spare Parts & Accessories 8

8 spare parts · click to collapse
Order codeDescription
71321494CYA680 spare part: O-ring (KALREZ)Details
71321495CYA680 Spare Parts: O-ring (VITON)Details
71321496CYA680 spare part: O-ring (EPDM)Details
71321497CYA680 spare part: 120 mm blind sensor, 316LDetails
71321498CYA680 spare parts: 120mm blind sensor, PVDFDetails
71321499CYA680 Spare Parts: 120 mm pH Sensor Adapter, 316LDetails
71323973CYA680 Spare Part: 120mm pH Sensor Adapter, PVDFDetails
71361303KIT CYA680 cd sensor adapter, 120mm, 316LDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Product comparison

Please enter the product order codes to be compared in the input boxes below; a maximum of three products can be compared

 

Technical documentation

  

 

 

Accessories / Spare parts

 

Source:Endress+Hauser website public information

All documents for this model
4 documents · click to expand
BA

BA CYA680 Chinese

Rev. 0323 20 pages
Preview
BA

BA CYA680 English

Rev. 0323 20 pages
Preview
TI

TI CYA680 Chinese

Rev. 0323 8 pages
Preview
TI

TI CYA680 English

Rev. 0323 8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.