Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CYR10B Injektor

CYR10B Injektor
Injektor CYR10B
The injector CYR10B enables the realization of fully automated sensor cleaning systems including cleanser dosing. Dosing is realized by motive water which generates a negative pressure and thus allows the suction of a liquid without an extra dosing pump. The cleaning control is carried out via the Chemoclean functionality of the Liquiline CM44 transmitters and allows individually configurable cleaning or rinsing cycles.
Compare

pH

Measuring Principle Potentiometric
Application Automatic cleaning
Characteristic Vacuum pump (driven by motion water)
Material PVC

Application
The spray head CYR10B doses cleaning liquid for fully automatic sensor cleaning. The cleaning liquid is sprayed by water pressure, so no filling pump needs to be installed. The cleaning process is controlled by the Chemoclean function (Liquiline CM44 transmitter), and the cleaning or rinsing intervals can be freely set.

The CYR10B cleaning spray head sprays and cleans pH/ORP electrodes, dissolved oxygen sensors and turbidity sensors.

Benefits
Water-pressure-controlled dosing volume of cleaning liquid (vacuum pump), easy operation

  • Adjustable cleaning liquid concentration

  • Cyclic rinsing and cleaning without an additional sample pump

  • Rinsing module made of plastic, with high chemical resistance

  • Can be conveniently mounted on a wall or panel

 

Spare Parts & Accessories 17

17 spare parts · click to collapse
Order codeDescription
71461443CYR10B valve block kit, PVCDetails
71461445Kit CYR10B water valve 110VDetails
71461446CYR10B cleaner valve kit 110VDetails
71461447Kit CYR10B water valve 230VDetails
71461448Kit CYR10B cleaner valve 230VDetails
71461449Kit CYR10B water valve 24VDetails
71461450Kit CYR10B cleaner valve 24VDetails
71461451CYR10B wear parts kit for water valveDetails
71461452Kit CYR10B wearing parts check valveDetails
71462914Kit CYR10B Hose connection setDetails
71461440Kit CYR10B connector plugDetails
71390988Water filter kitDetails
71390990Water filter strainer element kitDetails
50090491Hose connectorfor porge chamber for CPA450Details
51502808Hose connectorHose connection set 1.4404, G 1/4"/DN12Details
51511591Hose Connection AssemblyHose connection set PVDF G 1/4"/D16Details
51511590Hose Connection AssemblyHose connection set 1.4404, G 1/4"/D16Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

 

 

Accessories / Spare parts

 

Source: Endress+Hauser public website information

All documents for this model
2 documents · click to expand
BA

Chemoclean CYR10B English

Rev. 0119 52 pages
Preview
TI

Chemoclean CYR10B English

Rev. 0120 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.