FDR56 微波限位栅接收器

FDR56  微波限位栅接收器

Soliwave FDR56

The Soliwave FDR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR56 emitter.
Compare

Point Level / Solids

Measuring Principle Microwave barrier
Characteristic / Application Transceiver
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Installation:
Non-contact installation (transmission window) or front-flush installation (contact)
Specialities Measuement range: max. 100 m
Supply / Communication 85 ... 253 VAC
20 ... 60 VDC/ 20 ... 30 VAC
Ambient temperature -40°C...+70°C
(-40°F...+158°F)
Process temperature Non-contact installation: any
Within installation:
-40°C...+70°C (-40°F...+158°F)
With high temperature adapter:
up to +450°C (+842°F)
Process pressure / max. overpressure limit Non-contact installation: any
Within installation:
0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs.
Min. density of medium Solid weight: > 10 g/l
Main wetted parts Non-contact installation:
no wetted parts
Within installation:
316Ti or Aluminium;
PTFE or Ceramic
Process connection 1-1/2" R, 1-1/2" G, 1-1/2" NPT
Process connection hygienic Non-contact installation
Communication Relays SPDT
Solid-State-Relaiy
4 ... 20 mA
Certificates / Approvals ATEX, CSA C/US, IEC Ex
Design approvals EN10204-3.1
Options Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55
Components Transmitter: FQR56
Application limits Solid weight: < 10 g/l

The Soliwave FDR56 microwave limit switch receiver is suitable for non-contact limit detection. It can be installed in vessels, ducts, screw conveyors or free-fall chutes, or outside non-metallic vessels for measurement, control and counting of various types of granular solids. It can be used together with the Soliwave FQR56 transmitter.

 

Advantages

Flush, non-contact installation

Easy installation using R 1-1/2- or 1-1/2 NPT thread

The electronics housing can be rotated 360° to set the device to the optimum position after installation.

Robust mechanical design:

- no wear;

- ceramic sensor diaphragm for the wetted part (optional);

- long service life;

- maintenance-free.

Signal strength can be displayed on the receiver.

Direct power supply connection (transmitter and receiver can be used separately or together)

Complies with ATEX 1/2GD and IECEx standards.

 

Application areas

The Soliwave microwave limit switch is suitable for non-contact limit detection. It can be installed in vessels, ducts, screw conveyors or free-fall chutes, or outside non-metallic vessels, for measuring, controlling and counting various types of granular solids or bagged or boxed packages. Typically measured granular solids include: wood chips, wood dust and flour, gypsum, cement and lime, paper and cardboard, gravel and sand, and common dry powders.

 

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

reparts.jsp?root=FDR56&country=cn&lang=zh" style="visibility: visible;" width="1000">

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Microwave Level Switch Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Microwave Level Switch Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Microwave Level Switch Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Microwave Level Switch Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.