The Soliwave FDR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR56 emitter.
Compare

Point Level / Solids

Measuring Principle Microwave barrier
Characteristic / Application Transceiver
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Installation:
Non-contact installation (transmission window) or front-flush installation (contact)
Specialities Measuement range: max. 100 m
Supply / Communication 85 ... 253 VAC
20 ... 60 VDC/ 20 ... 30 VAC
Ambient temperature -40°C...+70°C
(-40°F...+158°F)
Process temperature Non-contact installation: any
Within installation:
-40°C...+70°C (-40°F...+158°F)
With high temperature adapter:
up to +450°C (+842°F)
Process pressure / max. overpressure limit Non-contact installation: any
Within installation:
0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs.
Min. density of medium Solid weight: > 10 g/l
Main wetted parts Non-contact installation:
no wetted parts
Within installation:
316Ti or Aluminium;
PTFE or Ceramic
Process connection 1-1/2" R, 1-1/2" G, 1-1/2" NPT
Process connection hygienic Non-contact installation
Communication Relays SPDT
Solid-State-Relaiy
4 ... 20 mA
Certificates / Approvals ATEX, CSA C/US, IEC Ex
Design approvals EN10204-3.1
Options Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55
Components Transmitter: FQR56
Application limits Solid weight: < 10 g/l

The Soliwave FDR56 microwave limit switch receiver is suitable for non-contact limit detection. It can be installed in vessels, ducts, screw conveyors or free-fall chutes, or outside non-metallic vessels for measurement, control and counting of various types of granular solids. It can be used together with the Soliwave FQR56 transmitter.

  • Advantages

  • Flush, non-contact installation

  • Easy installation using R 1-1/2- or 1-1/2 NPT thread

  • The electronics housing can be rotated 360° to set the device to the optimum position after installation.

  • Robust mechanical design:

  • no wear;

  • ceramic sensor diaphragm for the wetted part (optional);

  • long service life;

  • maintenance-free.

  • Signal strength can be displayed on the receiver.

  • Direct power supply connection (transmitter and receiver can be used separately or together)

  • Complies with ATEX 1/2GD and IECEx standards.

  • Application areas

  • The Soliwave microwave limit switch is suitable for non-contact limit detection. It can be installed in vessels, ducts, screw conveyors or free-fall chutes, or outside non-metallic vessels, for measuring, controlling and counting various types of granular solids or bagged or boxed packages. Typically measured granular solids include: wood chips, wood dust and flour, gypsum, cement and lime, paper and cardboard, gravel and sand, and common dry powders.

Spare Parts & Accessories 150

150 spare parts · click to collapse
Order codeDescription
71125423*** Electronic ModuleElectronic module receiver. Non-hazardous area, relay, AC version. Compatible for devices that have been delivered until 30.04.2016. Usage: FDR56.Details
71125424*** Electronic ModuleElectronic module receiver. Non-hazardous area, relay, DC version. Compatible for devices that have been delivered until 30.04.2016. Usage: FDR56.Details
71125425Electronic plug-in D-AA2A, FDR56 receiver electronic module, non-explosion-proof area, 4-20mAElectronic module receiver. Non-hazardous area, 4-20mA, AC version. Usage: FDR56.Details
71125426Electronic plug-in module D-AA2E, FDR56 receiver electronic module, non-hazardous area, 4-20 mAElectronic module receiver. Non-hazardous area, 4-20mA, DC version. Usage: FDR56.Details
71125427Electronic plug-in module D-AA3A, FDR56 receiver electronic module, non-hazardous area, solid-state relay, AElectronic module receiver. Non-hazardous area, solid-state-relay, AC version. Usage: FDR56.Details
71125428Electronic plug-in module D-AA3E, FDR56 receiver electronic module, non-hazardous area, solid-state relay, DElectronic module receiver. Non-hazardous area, solid-state-relay, DC version. Usage: FDR56.Details
71125429*** Electronic ModuleElectronic module receiver. ATEX II 1/2D IP66 T102oC, relay, AC version. Compatible for devices that have been delivered until 30.04.2016. Usage: FDR56.Details
71125430*** Electronic ModuleElectronic module receiver. ATEX II 1/2D IP66 T102oC, relay, DC version. Compatible for devices that have been delivered until 30.04.2016. Usage: FDR56.Details
71125431Electronic plug-in module D-BA2A, FDR56 receiver electronic module, ATEX II 1/2D IPElectronic module receiver. ATEX II 1/2D IP66 T102oC, 4-20mA, AC version. Usage: FDR56.Details
71125432Electronic plug-in D-BA2E, FDR56 receiver electronic module, ATEX II 1/2D IPElectronic module receiver. ATEX II 1/2D IP66 T102oC, 4-20mA, DC version. Usage: FDR56.Details
71125433Electronic plug-in module D-BA3A, FDR56 receiver electronics module, ATEX II 1/2D IPElectronic module receiver. ATEX II 1/2D IP66 T102oC, solid-state-relay, AC version. Usage: FDR56.Details
71125434Electronic insert D-BA3E, FDR56 receiver electronic module, ATEX II 1/2D IPElectronic module receiver. ATEX II 1/2D IP66 T102oC, solid-state-relay, DC version. Usage: FDR56.Details
71125436*** Electronic ModuleElectronic module receiver. IECEx II 1/2D IP66 T102oC, relay, AC version. Compatible for devices that have been delivered until 30.04.2016. Usage: FDR56.Details
71125437*** Electronic ModuleElectronic module receiver. IECEx II 1/2D IP66 T102oC, relay, DC version. Compatible for devices that have been delivered until 30.04.2016. Usage: FDR56.Details
71125438Electronic plug-in module D-IA2A, FDR56 receiver electronic module. IECEx II 1/2D IElectronic module receiver. IECEx II 1/2D IP66 T102oC, 4-20mA, AC version. Usage: FDR56.Details
71125439Electronic plug-in module D-IA2E, FDR56 receiver electronic module, IECEx II 1/2D IElectronic module receiver. IECEx II 1/2D IP66 T102oC, 4-20mA, DC version. Usage: FDR56.Details
71125440Electronic plug-in module D-IA3A, FDR56 receiver electronic module.IECEx II 1/2DElectronic module receiver. IECEx II 1/2D IP66 T102oC, Solid-state-relay, AC version. Usage: FDR56.Details
71125441Electronic plug-in module D-IA3E, FDR56 receiver electronic module. IECEx II 1/2DElectronic module receiver. IECEx II 1/2D IP66 T102oC, Solid-state-relay, DC version. Usage: FDR56.Details
71258315Electronic plug-in module D-CA1A, FDR56 receiver electronic module, CSA General PElectronics receiver. CSA General Purpose, relay, AC version. Usage: FDR56.Details
71258316Electronic plug-in module D-CA1E, FDR56 receiver electronic module, CSA General PElectronics receiver. CSA General Purpose, relay, DC version. Usage: FDR56.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Accessories / Spare parts

reparts.jsp?root=FDR56&country=cn&lang=zh" style="visibility: visible;" width="1000">

Source:Endress+Hauserpublic information from the website

All documents for this model
8 documents · click to expand
BA

BA Soliwave FQR56/FDR56 English

Rev. 0424 60 pages
Preview
TI

TI Soliwave FDR56/FQR56 English

Rev. 2024 40 pages
Preview
TI

TI Accessory FAR50 English

Rev. 0425 8 pages
Preview
TI

TI Accessory FAR52 English

Rev. 0325 8 pages
Preview
TI

TI Accessory FAR51 English

Rev. 0325 8 pages
Preview
TI

TI Accessory FAR54 English

Rev. 0319 8 pages
Preview
TI

TI Accessory FAR55 English

Rev. 0225 8 pages
Preview
TI

TI Accessory FAR53 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · microwave limit — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted microwave limit properly configured on the existing plant, with the aim of microwave point-level detection for solids or liquids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the microwave limit configuration has to involve choosing contacting or non-contacting by stickiness and mounting position.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing contacting or non-contacting by stickiness and mounting position, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is build-up does not affect switching, keeping point detection dependable, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · microwave limit — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was microwave point-level detection for solids or liquids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing contacting or non-contacting by stickiness and mounting position.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing contacting or non-contacting by stickiness and mounting position, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — build-up does not affect switching, keeping point detection dependable, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · microwave limit — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from microwave limit, focusing on microwave point-level detection for solids or liquids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The microwave limit specification must therefore cover choosing contacting or non-contacting by stickiness and mounting position.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing contacting or non-contacting by stickiness and mounting position, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — build-up does not affect switching, keeping point detection dependable, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · microwave limit — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is microwave limit; the focus is microwave point-level detection for solids or liquids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing contacting or non-contacting by stickiness and mounting position.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing contacting or non-contacting by stickiness and mounting position, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means build-up does not affect switching, keeping point detection dependable, which cut the workload on the site maintenance team.