Solimotion FTR20
Technical Data
ComparePoint Level / Solids
| Measuring Principle | Microwave barrier |
| Characteristic / Application | Flow indicator for bulk solids Non-contact motion detection (movement / no movement) of pneumatically or mechanically conveyed bulk solids of all kinds, also in potentially explosive atmospheres (dust Ex) Detection of changes in the mass flow of bulk solids via the optional 4 - 20 mA current output |
| Ambient temperature | -40°C ... +70°C (-40°F...158°F) |
| Process temperature | -40°C ... +70°C (-40°F ...+158°F) With high temperature adapter: up to +450°C (+842°F) |
| Process pressure / max. overpressure limit | 0.5 ... 6.8 bar abs. (7.2 ... 98.6 psi abs.) With high pressure adapter: up to 5.1 bar (74 psi) abs. |
| Main wetted parts | 316Ti/1.4571 Sensor diaphragm: PTFE or ceramic |
| Process connection | Thread R 1½ (EN 10226) NPT 1½ (ASME B1.20.1) |
| Communication | Relay SPDT Analog 4 - 20 mA Solid-state relay |
| Certificates / Approvals | ATEX, CSA C/US, IEC Ex |
| Design approvals | EN10204-3.1 |
| Options | Adapter for temperature reduction |
The Solimotion FTR20 solids flow indicator is a non-contact measuring instrument based on microwave technology, especially suitable for monitoring mass flow (in real time or not in real time), economical and practical. With its compact design, it is a cost-effective solution for monitoring the conveying process of bulk solids. It can be adjusted individually to the application via configuration functions such as automatic calibration.
Benefits
Compact device: sensor, transmitter and power supply unit are installed in the same housing for easy installation.
Cost-effective monitoring of the mass flow of bulk solids (in real time or not in real time).
Non-contact, flush installation.
Easy installation using R 1½ or 1½ NPT thread or a mounting bracket.
The electronics housing can be rotated through 360°, so the device can be optimally aligned after installation.
Robust mechanics: no wear; optional ceramic diaphragm for wetted parts; long service life; maintenance-free.
Mass flow signal
Application
Typical areas of application and bulk solids include:
Building materials industry: cement, plaster, wood chips, etc.
Chemical industry: fertilizers, plastic powders and granules, silica, etc.
Food industry: coffee, tea, tobacco, cereals, malt, animal feed, etc.
Energy generation industry: coal, coal dust, fly ash, coke, etc.
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Microwave Level Switch Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Microwave Level Switch Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Microwave Level Switch Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Microwave Level Switch Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.