Soliwave FQR56
Technical Data
ComparePoint Level / Solids
| Measuring Principle | Microwave barrier |
| Characteristic / Application | Transmitter Non-contact point level detection and flow monitoring Detecting, counting and positioning of objects Monitoring of material transfer points Detection and analysis of deposits and contamination Installation: Non-contact installation (transmission window) or front-flush installation (contact) |
| Specialities | Measurement range: max. 100 m |
| Supply / Communication | 85 ... 253VAC 20 ... 30 VDC/ 20 ... 60 VAC |
| Ambient temperature | -40°C...+70°C (-40°F...+158°F) |
| Process temperature | Non-contact installation: any Within installation: -40°C...+70°C (-40°F...+158°F) With high temperature adapter: up to +450°C (+842°F) |
| Process pressure / max. overpressure limit | Non-contact installation: any Within installation: 0.5 bar...6.8 bar (7.2 psi...99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs. |
| Min. density of medium | Solid weight: > 10 g/l |
| Main wetted parts | Non-contact installation: no wetted parts Within installation: 316Ti or Aluminium; PTFE or Ceramic |
| Process connection | 1-1/2" R, 1-1/2" G, 1-1/2" NPT |
| Process connection hygienic | Non-contact installation |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US |
| Design approvals | EN10204-3.1 |
| Options | Sight glass High temperature adapter High pressure adapter Installation bracket FAR50, FAR51, FAR52, FAR53, FAR54, FAR55 |
| Components | Transceiver: FDR56 |
| Application limits | Solid weight: < 10 g/l |
The Soliwave FQR56 microwave barrier transmitter is suitable for non-contact limit detection and can be installed in vessels, ducts, shafts or free-fall shafts, or outside non-metallic vessels for measuring, controlling and counting various types of bulk solids. It can be used together with the Soliwave FDR56 receiver.
Benefits
Flush, non-contact installation
Easy installation using an R 1-1/2 or 1-1/2 NPT thread
The electronics housing can be rotated through 360°, so the device can be optimally aligned after installation.
Robust mechanical design:
- no wear;
- optional ceramic sensor diaphragm for wetted parts;
- long service life;
- maintenance-free.
The signal strength can be displayed on the receiver.
Direct power connection (transmitter and receiver can be used separately or together)
Compliant with ATEX 1/2GD and IECEx standards
Application
The Soliwave microwave limit switch is suitable for non-contact limit detection and can be installed in vessels, ducts, shafts or free-fall shafts, or outside non-metallic vessels for measuring, controlling and counting various types of bulk solids as well as bagged or boxed packages. Typical bulk solids measured include: wood chips, wood dust and flour, gypsum, cement and lime, paper and cardboard, gravel and sand, and common dry powders.
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Microwave Level Switch Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Microwave Level Switch Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Microwave Level Switch Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Microwave Level Switch Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.