Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FQR56 Soliwave

FQR56 Soliwave
Soliwave FQR56
Configurable Models 1 models
The Soliwave FQR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FDR56 receiver.
Compare

Point Level / Solids

Measuring Principle Microwave barrier
Characteristic / Application Transmitter
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Installation:
Non-contact installation (transmission window) or front-flush installation (contact)
Specialities Measurement range: max. 100 m
Supply / Communication 85 ... 253VAC
20 ... 30 VDC/ 20 ... 60 VAC
Ambient temperature -40°C...+70°C
(-40°F...+158°F)
Process temperature Non-contact installation: any
Within installation:
-40°C...+70°C (-40°F...+158°F)
With high temperature adapter:
up to +450°C (+842°F)
Process pressure / max. overpressure limit Non-contact installation: any
Within installation:
0.5 bar...6.8 bar (7.2 psi...99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs.
Min. density of medium Solid weight: > 10 g/l
Main wetted parts Non-contact installation:
no wetted parts
Within installation:
316Ti or Aluminium;
PTFE or Ceramic
Process connection 1-1/2" R, 1-1/2" G, 1-1/2" NPT
Process connection hygienic Non-contact installation
Certificates / Approvals ATEX, IEC Ex, CSA C/US
Design approvals EN10204-3.1
Options Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55
Components Transceiver: FDR56
Application limits Solid weight: < 10 g/l

Product Overview

The Soliwave FQR56 microwave barrier transmitter is suitable for non-contact limit detection and can be installed in vessels, ducts, shafts or free-fall shafts, or outside non-metallic vessels for measuring, controlling and counting various types of bulk solids. It can be used together with the Soliwave FDR56 receiver.

  • Benefits

  • Flush, non-contact installation

  • Easy installation using an R 1-1/2 or 1-1/2 NPT thread

  • The electronics housing can be rotated through 360°, so the device can be optimally aligned after installation.

  • Robust mechanical design:

  • no wear;

  • optional ceramic sensor diaphragm for wetted parts;

  • long service life;

  • maintenance-free.

  • The signal strength can be displayed on the receiver.

  • Direct power connection (transmitter and receiver can be used separately or together)

  • Compliant with ATEX 1/2GD and IECEx standards

  • Application

  • The Soliwave microwave limit switch is suitable for non-contact limit detection and can be installed in vessels, ducts, shafts or free-fall shafts, or outside non-metallic vessels for measuring, controlling and counting various types of bulk solids as well as bagged or boxed packages. Typical bulk solids measured include: wood chips, wood dust and flour, gypsum, cement and lime, paper and cardboard, gravel and sand, and common dry powders.

Spare Parts & Accessories 94

94 spare parts · click to collapse
Order codeDescription
71125417Plug-in electronic module Q-AAA, FQR56 transmitter electronic module, non-hazardous area, AC version, applicableElectronic module emitter. Non-hazardous area, AC version. Usage: FQR56.Details
71125418Electronic insert Q-AAE, FQR56 transmitter electronics module. Non-hazardous area, DC version. Applicable.Electronic module emitter. Non-hazardous area, DC version. Usage: FQR56.Details
71125419Electronic plug-in module Q-BAA, FQR56 mittElectronic module mitter. ATEX II 1/2D IP66 T102oC, AC version. Usage: FQR56.Details
71125420Electronic plug-in module Q-BAE, FQR56 transmitter electronics module. ATEX II 1/2D IElectronic module emitter. ATEX II 1/2D IP66 T102oC, DC version. Usage: FQR56.Details
71125421Electronic plug-in Q-IAA, FQR56 transmitter electronic module, IECEx II 1/2DElectronic module emitter. IECEx II 1/2D IP66 T102oC, AC version. Usage: FQR56.Details
71125422Electronic insert Q-IAE, FQR56 transmitter electronic module, IECEx II 1/2DElectronic module emitter. IECEx II 1/2D IP66 T102oC, DC version. Usage: FQR56.Details
71258291Electronic plug-in module Q-CAA, FQR56 transmitter electronic module, CSA General PurposeElectronics emitter. CSA General Purpose, AC version. Usage: FQR56.Details
71258311Electronic Plug-in Module Q-CAE, FQR56 Transmitter Electronic Module, CSA General PuElectronics emitter. CSA General Purpose, DC version. Usage: FQR56.Details
71258313Electronic plug-in module Q-CBA, FQR56 transmitter electronic module. CSA C/US ClassElectronics emitter. CSA C/US Class II, Div. 1, Group E-G, AC version. Usage: FQR56.Details
71258314Electronic insert Q-CBE, FQR56 transmitter electronic module, CSA C/US ClassElectronics emitter. CSA C/US Class II, Div. 1, Group E-G, DC version. Usage: FQR56.Details
71324242Electronic Plugin Q-AAA, FQR56 (F34) Transmitter Electronic Module, non-hazardous area, AElectronic module emitter. Non-hazardous area, AC version. Usage: FQR56.Details
71324243Electronic plug-in module Q-AAE, FQR56 (F34), transmitter electronic module, non-hazardous area, DElectronic module emitter. Non-hazardous area, DC version. Usage: FQR56.Details
71324246Electronic insert Q-BAA, FQR56 (F34), transmitter electronics module, ATEX IIElectronic module emitter. ATEX II 1/2D IP66 T102oC, AC version. Usage: FQR56.Details
71324247Electronic insert Q-BAE, FQR56 (F34), transmitter electronics module, ATEX IIElectronic module emitter. ATEX II 1/2D IP66 T102oC, DC version. Usage: FQR56.Details
71324250Electronic plug-in module Q-IAA, FQR56 (F34), transmitter electronics module, IECEx IIElectronic module emitter. IECEx II 1/2D IP66 T102oC, AC version. Usage: FQR56.Details
71324252Electronic plug-in card Q-IAE, FQR56 (F34) transmitter electronics module. IECEx IIElectronic module emitter. IECEx II 1/2D IP66 T102oC, DC version. Usage: FQR56.Details
71674351Electronic module Q-UAA, FQR56Electronic module. UK Ex ta/tb IIIC T102oC Da/Db. AC version. Usage: FQR56.Details
71674356Electronic module Q-UAA, FQR56 (F34)Electronic module. UK Ex ta/tb IIIC T102oC Da/Db. AC version. Usage: FQR56.Details
71674358Electronic module Q-UAE, FQR56Electronic module. UK Ex ta/tb IIIC T102oC Da/Db. DC version. Usage: FQR56.Details
71674359Electronic module Q-UAE, FQR56 (F34)Electronic module. UK Ex ta/tb IIIC T102oC Da/Db. DC version. Usage: FQR56.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

1 models · click to collapse
All documents for this model
8 documents · click to expand
BA

BA Soliwave FQR56/FDR56 English

Rev. 0424 60 pages
Preview
TI

TI Soliwave FDR56/FQR56 English

Rev. 2024 40 pages
Preview
TI

TI Accessory FAR50 English

Rev. 0425 8 pages
Preview
TI

TI Accessory FAR52 English

Rev. 0325 8 pages
Preview
TI

TI Accessory FAR51 English

Rev. 0325 8 pages
Preview
TI

TI Accessory FAR54 English

Rev. 0319 8 pages
Preview
TI

TI Accessory FAR55 English

Rev. 0225 8 pages
Preview
TI

TI Accessory FAR53 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · microwave limit — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted microwave limit properly configured on the existing plant, with the aim of microwave point-level detection for solids or liquids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the microwave limit configuration has to involve choosing contacting or non-contacting by stickiness and mounting position.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing contacting or non-contacting by stickiness and mounting position, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is build-up does not affect switching, keeping point detection dependable, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · microwave limit — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was microwave point-level detection for solids or liquids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing contacting or non-contacting by stickiness and mounting position.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing contacting or non-contacting by stickiness and mounting position, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — build-up does not affect switching, keeping point detection dependable, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · microwave limit — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from microwave limit, focusing on microwave point-level detection for solids or liquids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The microwave limit specification must therefore cover choosing contacting or non-contacting by stickiness and mounting position.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing contacting or non-contacting by stickiness and mounting position, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — build-up does not affect switching, keeping point detection dependable, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · microwave limit — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is microwave limit; the focus is microwave point-level detection for solids or liquids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing contacting or non-contacting by stickiness and mounting position.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing contacting or non-contacting by stickiness and mounting position, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means build-up does not affect switching, keeping point detection dependable, which cut the workload on the site maintenance team.