FMA90 Control Unit FlexView

FMA90 Control Unit FlexView
Control Unit FlexView FMA90
Configurable Models 7 models
Flexible control unit for radar, ultrasonic and hydrostatic level sensors with visualization, enhanced control and remote monitoring.
Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
Specialities Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors
Supply / Communication 100 … 230 VAC;
10.5 … 32 VDC
Ambient temperature -40 to +60 °C (-40 to +140 °F) (Type tested);
-35 to +60 °C (-31 to +140 °F) (approved by CSA)
Communication Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN)
Certificates / Approvals ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC
Options 3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, guided wizzards vor commissioning, up to two level sensors
Housing:
Panel-mounted / DIN rail / Field
Components Sensors: FMR10B, FMR20B, FMR30B, FMX21, FMU30

Continuous / Solids

Measuring Principle Level radar solid
Characteristic / Application Level, pump control,open channel flow measurement, data logging, rake control, storm overflow basin
Specialities Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors
Supply / Communication 100 … 230 VAC;
10.5 … 32 VDC
Ambient temperature –40 to +60 °C (–40 to +140 °F) (Type tested);
–35 to +60 °C (–31 to +140 °F) (approved by CSA)
Communication Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN)
Certificates / Approvals ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC
Options 3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, guided wizzards vor commissioning, up to two level sensors
Housing:
Panel-mounted / DIN rail / Field
Components Sensors: FMR10B, FMR20B, FMR30B, FMX21, FMU30

Pressure

Measuring Principle Hydrostatic pressure
Characteristic Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
Supply voltage 100 … 230 VAC;
10.5 … 32 VDC
Ambient temperature -40 to +60 °C (-40 to +140 °F) (Type tested);
-35 to +60 °C (-31 to +140 °F) (approved by CSA)
Communication Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN)
Certificates / Approvals ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC
Specialities Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors

FMA90 control unit with color display and touch function for connecting up to two ultrasonic, radar, hydrostatic or universal 4...20 mA/HART® level sensors
Application
• Level measurement: level linearization and setpoint monitoring for alarm output
• Level measurement: multiple pump control options, controlling up to eight pumps
• Differential level measurement: control calculation using two sensors
• Flow measurement in open channels or measuring weirs, with optional backwater detection
• Flow measurement: counting pulse output to external devices and flow totalizers
• Flow measurement in stormwater overflow basins
Advantages
• Equipped with a 3.5" color display with touch control or an integrated web server for easy operation
• Ethernet or wireless WLAN communication
• Compatible with all two-wire or four-wire level transmitters with 4...20 mA/HART interface
• Guided setup wizard for fast and simple commissioning
• Automatic detection and configuration of the following Endress+Hauser sensors: Micropilot FMR20B, FMR30B,
and Waterpilot FMX21
• Optional international gas explosion protection and dust explosion protection certification
• Wide range of applications, available as field housing, DIN rail device or panel-mounted device

Spare Parts & Accessories 38

38 spare parts · click to collapse
Order codeDescription
71706829Housing front + display FMA90, DIN railDetails
71706830Front housing w/o display FMA90 DIN railDetails
71706832Hinge joint FMA90 DIN railDetails
71706822Bus board FMA90 DIN railDetails
XPF0053-CPU + Software FMA90Attention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
XPF0054-Upgrade codeAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
71706826Relay + power supply DIN rail + panel 24VDCOutput: 5x relay (2x SPDT, 3x SPST). Relay 2-5 must be activated in FW.Details
71706828Relay + power supply, DIN rail + panel, 230 VACOutput: 5x relay (2x SPDT, 3x SPST). Relay 2-5 must be activated in FW.Details
71706835Terminal plug-in 2-pole "L/+ N/-" pitch 5.0Fitting for power supply FMA90.Details
71706836Terminal set relay FMA90 DIN rail+panel2x 3pol RM 5.0 (relay 1,2). 3x 2pol RM 5.0 (relay 3,4,5). 1x 2pol RM 5.0 (power supply).Details
71706823Standard IO board FMA90, DIN rail + panel mountingSensor input: 1x 4-20mA HART. Digital input: 4x DI IN. Output: 1x 4-20mA (opt. HART), 1x OC. DI (1-4) must be activated in FW.Details
71706833Terminal set Std-IO FMA90, DIN rail + panel mounting1x 4pol RM3.5 (A01, OC1). 1x 6pol RM3.5 (DI1-4). 1x 4pol RM3.5 (AI1).Details
71706825Option I/O board FMA90 DIN rail + panelSensor input: 1x 4-20mA HART. Output: 1x 4-20mA, 2x OC.Details
71706834Terminal set Opt-IO FMA90 DIN rail+panel1x 6pol RM3.5 (A02, OC2, OC3). 1x 4pol RM3.5 (AI2).Details
71706839Front housing + display FMA90 panelDetails
XPF0053-CPU + Software FMA90Attention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
71706838Bus board FMA90 panelDetails
71706826Relay + power supply DIN rail + panel 24VDCOutput: 5x relay (2x SPDT, 3x SPST). Relay 2-5 must be activated in FW.Details
71706828Relay + power supply, DIN rail + panel, 230 VACOutput: 5x relay (2x SPDT, 3x SPST). Relay 2-5 must be activated in FW.Details
71706823Standard IO board FMA90, DIN rail + panel mountingSensor input: 1x 4-20mA HART. Digital input: 4x DI IN. Output: 1x 4-20mA (opt. HART), 1x OC. DI (1-4) must be activated in FW.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
7 models · click to collapse
Diagnostic codes(80 条)→
All documents for this model
8 documents · click to expand
BA

BA FlexView FMA90 Chinese

Rev. 0226 84 pages
Preview
BA

BA FlexView FMA90 Chinese

Rev. 0126 100 pages
Preview
BA

BA FlexView FMA90 Chinese

Rev. 0126 88 pages
Preview
BA

BA FlexView FMA90 English

Rev. 0226 88 pages
Preview
BA

BA FlexView FMA90 English

Rev. 0126 102 pages
Preview
BA

BA FlexView FMA90 English

Rev. 0126 92 pages
Preview
TI

TI FlexView FMA90 Chinese

Rev. 0225 32 pages
Preview
TI

TI FlexView FMA90 English

Rev. 0326 32 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ultrasound — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from ultrasound , focusing on ultrasonic liquid level measurement or interface detection.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The ultrasound specification must therefore cover sizing range against dead zone, mounting height and medium temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing range against dead zone, mounting height and medium temperature, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — retrofit without touching the tank, with short installation time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · ultrasound — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is ultrasound ; the focus is ultrasonic liquid level measurement or interface detection.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing range against dead zone, mounting height and medium temperature.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing range against dead zone, mounting height and medium temperature, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means retrofit without touching the tank, with short installation time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ultrasound — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on ultrasound and the core task is ultrasonic liquid level measurement or interface detection.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So ultrasound cannot be specified generically — it calls for sizing range against dead zone, mounting height and medium temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing range against dead zone, mounting height and medium temperature, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is retrofit without touching the tank, with short installation time.

Power & Energy

Power & Energy · ultrasound — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted ultrasound properly configured on the existing plant, with the aim of ultrasonic liquid level measurement or interface detection.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the ultrasound configuration has to involve sizing range against dead zone, mounting height and medium temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant sizing range against dead zone, mounting height and medium temperature, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is retrofit without touching the tank, with short installation time, and the readings are now used for process tuning.