Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

OUA260 Flow cell

OUA260 Flow cell
Flow cell OUA260
OUA260 is the best-in-class flow assembly for optical inline sensors measuring absorption, color or turbidity. Its ultra-hygienic design and certified biocompatibility meet the highest demands to protect your products reliably from contamination. Learn more!
Compare

Concentration

Measuring Principle UV absorbance
Application Flow assembly for use in combination with photometric sensors OUSAFxx and OUSTF10
Material Body: Stainless steel AISI 316L, 1.4435, PVDF, other materials
available on request
Windows: Quartz, Sapphire or Borosilicate
O-rings: Viton, Silicone, EPDM, Kalrez
Process temperature 0 to 130 °C (32 to 266 °F)
Process pressure up to 20 bar (290 psi) depending on material, mean diameter and process connection

OUA260 is the optimum flow assembly for UV absorption, near-infrared (NIR) absorption, color and turbidity measurement. It features an extremely hygienic design and biocompatibility certification, meeting the highest requirements for protecting products from contamination. Various process connections and available materials ensure perfect adaptability and performance even in aggressive media. Even better, its low media hold-up volume accelerates sensor response time and provides measured values in the shortest possible time.

Advantages

  • Small flow cell volume, fast measurement

  • Resistant to CIP and SIP cleaning

  • Certified biocompatibility in accordance with USP Cl. VI

  • Electropolished, highly hygienic, surface roughness down to Ra = 0.4 μm (16 μinch)

  • Extreme corrosion resistance

  • Various materials and process connections available, perfectly suitable for all application conditions

  • Optical windows and path lengths in various materials available to meet process requirements

Application

  • The OUA260 flow cell can be combined with the following instruments:

  • OUSAF12 suspended solids and color sensor

  • OUSAF22 color sensor

  • OUSAF44 UV absorption sensor

  • OUSTF10 turbidity and suspended solids sensor

  • Typical applications include:

  • Chromatography control

  • Filtration monitoring

  • Color measurement

  • Centrifuge control

  • Protein concentration

  • Turbidity measurement

  • Interface detection

  • OUA260 is suitable for hazardous areas

Spare Parts & Accessories 53

53 spare parts · click to collapse
Order codeDescription
71136357OUA260 window O-ring, EPDM (USP)Details
71136358OUA260 window Kalrez O-ringDetails
71136359OUA260 sight glass O-ring, siliconeDetails
71136360OUA260 window O-ring, Viton (USP)Details
71210142OUA260 Window O-ring Buna "N"Details
71136387OUA260 quartz window 14 mm1x optical windowDetails
71136388OUA260 Quartz Window 16.5mm1x Optisches FensterDetails
71136389OUA260 Quartz Window 18.5 mm1x optical windowDetails
71136390OUA260 Quartz Window 18mm1x optical windowDetails
71136391OUA260 Quartz Window 19mm1x optical windowDetails
71136392OUA260 Quartz Window 21.5mm1x optical windowDetails
71136393OUA260 Quartz Window 23.5mm1x optical windowDetails
71136394OUA260 quartz window 23 mm1x optical windowDetails
71136395OUA260 Quartz Window 24 mm1x optical windowDetails
71136396***OUA260 Sight Glass 9mmDetails
71136397OUA260 Quartz Window 31.5 mm1x optical windowDetails
71136398OUA260 quartz window 33.5 mm1x optical windowDetails
71136400OUA260 Quartz Window 34mm1x optical windowDetails
71136406OUA260 Quartz Window 9mm1x optical windowDetails
71142621OUA260 Sight Glass 24mmDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
7 documents · click to expand
BA

BA OUA260 Chinese

Rev. 0625 24 pages
Preview
BA

BA OUA260 English

Rev. 0625 24 pages
Preview
TI

TI OUA260 Chinese

Rev. 1825 12 pages
Preview
TI

OUSAF44 Chinese

Rev. 1622 12 pages
Preview
TI

TI OUA260 English

Rev. 1825 12 pages
Preview
TI

OUSAF44 English

Rev. 1622 12 pages
Preview
TI

Model AF44 UV flow through sensor English

Rev. 0107 10 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · turbidity — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.

Food & Beverage

Food & Beverage · turbidity — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · turbidity — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · turbidity — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.