Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

OUSAF46 UV absorbance sensor

OUSAF46 UV absorbance sensor
UV absorbance sensor
Endress+Hauser OUSAF46
The OUSAF46 UV sensor monitors the concentration of your product at two discrete wavelengths. It covers a broad concentration range and supports you e.g. in optimizing chromatography control. Its outstanding filter performance ensures highest linearity and full consistency with lab results. This provides you with fast and reliable process information and increases your product yield. You also benefit from Easycal – the patented system for easy, liquid-free online calibration traceable to NIST.
Compare

Concentration

Measuring Principle UV absorbance
Application Measurement of protein concentrations, chromatography monitoring, filtration monitoring, concentration measurement of organic compounds, detection of aromates
Characteristic Sensor for installation in the pipe with separate flow assembly OUA260
Measuring range 0 to 2.5 AU
0 to 50 OD (depending on optical pathlength)
Design "
Material Sensor housing: stainless steel 316
Process temperature 0 to 90 °C (32 to 194 °F) continuous
Max. 130 °C (266 °F) for 2 hours
Process pressure Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly
Ex certification ATEX, FM
Ingress protection IP65 (NEMA4)
Certificates, declarations and approvals FDA

The OUSAF46 ultraviolet (UV) absorbance sensor detects media online and quantitatively at two specific UV wavelengths. The wide concentration range helps users optimize chromatographic analysis. Excellent filter performance provides the highest linearity and complete agreement with laboratory results. It provides users with fast, reliable process information to help increase yields. The patented Easycal system offers clear advantages, enabling convenient online dry calibration in compliance with NIST traceability requirements.

Benefits

  • Dual ultraviolet (UV) wavelengths for a wide measuring range

  • Fast, reliable monitoring of medium concentration for better process control and simplified quality control

  • Highly accurate measured values in complete agreement with laboratory results

  • The patented EasycalTM system enables NIST-traceable online dry calibration

  • Excellent filter performance with the highest linearity

  • Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)

Applications

  • The OUSAF46 sensor measures ultraviolet (UV) absorbance at two specific wavelengths:

  • Protein concentration detection

  • Chromatographic analysis

  • Permeate and precipitate monitoring

  • Organic compound concentration monitoring

  • Aromatic compound detection

  • Filter control

Spare Parts & Accessories 6

6 spare parts · click to collapse
Order codeDescription
71108535OUSAF44 lamp 280/295/302/313/365 nmFor OUSAF44, 46 ATEX and Non-Exp sensorsDetails
71108543OUSAF44 Reference RodDetails
71210161OUSxFxx Dust Cover ConnectorDetails
71382018KIT OUSAF46 Easycal Retrofit 254/280 nmDetails
71382019KIT OUSAF46 Easycal Retrofit 280/295 nmDetails
71382020KIT OUSAF46 Easycal Retrofit 280/313 nmDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: Endress+Hauserpublic information from the website

All documents for this model
4 documents · click to expand
BA

BA OUSAF46 Chinese

Rev. 0624 36 pages
Preview
BA

BA OUSAF46 English

Rev. 0624 36 pages
Preview
TI

OUSAF46 Chinese

Rev. 0522 12 pages
Preview
TI

OUSAF46 English

Rev. 0522 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · turbidity — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.

Food & Beverage

Food & Beverage · turbidity — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · turbidity — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · turbidity — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.