Order Code:PMC51-AA12QS1HGJRLJJ
Name:Cerabar M PMC51
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Output | 1 | 4-20mA |
| 030 | Display, Operation | 2 | W/o LCD, push button on electronics |
| 040 | Housing | Q | F15 stainless steel hygiene |
| 050 | Electrical Connection | S | Cable 5m, IP66/68 NEMA4X/6P + atmospheric pressure compensation via cable |
| 070 | Sensor Range | 1H | 1bar/100kPa/15psi gauge, 10mH2O/33ftH2O/400inH2O overload: 10bar/1MPa/150psi |
| 080 | Reference Accuracy | G | Standard |
| 090 | Calibration; Unit | J | Customised pressure; see additional spec. |
| 110 | Process Connection | RLJ | Thread ANSI MNPT1/2 FNPT1/4, 316L |
| 190 | Seal | J | EPDM, FDA |
Configuration Explained
This is a PMC51 digital pressure transmitter, oil-free ceramic sensor, very suitable for hygienic applications, non-hazardous area, 4-20mA output, no LCD screen, push button operation, F15 stainless steel hygienic housing, 5 m cable with atmospheric compensation tube, IP66/68, gauge pressure range 1 bar, 10 m water column, overpressure 10 bar, user-definable units, process connection MNPT1/2 with FNPT1/4, 316L, EPDM food grade sealing ring.