Cerabar S PMP75
Cerabar S PMP75;Approval Non-hazardous area;Output/Operating 4-20mA HART; inside + LCD;Housing/Cover Sealing/Cable Entry T17 316L hyg. IP66/68 NEMA6P;EPDM;NPT1/2 thread, T17 = side cover, hygiene;Sensor Range/Sensor Overload Limit 1bar/100kPa/15psi abs; 10bar/1MPa/150psi;Calibration/Unit Sensor range; kPa/MPa;Membrane Material AlloyC276;Process Connection DN50 PN10-40 B1, 316L, flush mount, flange EN1092-1;Transmitter Mounting/Fill Fluid Direct; silicone oil;Additional Option
Order Code:PMP75-2THP8/0
Corresponding ext. order code:PMP75-ABT2H22B3AAA
Name:Cerabar S PMP75
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | A | Non-hazardous area |
| 020 | Output; Operating | B | 4-20mA HART; inside + LCD |
| 030 | Housing; Cover Sealing; Cable Entry | T | T17 316L hyg. IP66/68 NEMA6P;EPDM;NPT1/2 thread, T17 = side cover, hygiene |
| 040 | Sensor Range; Sensor Overload Limit | 2H | 1bar/100kPa/15psi abs; 10bar/1MPa/150psi |
| 050 | Calibration; Unit | 2 | Sensor range; kPa/MPa |
| 060 | Membrane Material | 2 | AlloyC276 |
| 070 | Process Connection | B3 | DN50 PN10-40 B1, 316L, flush mount, flange EN1092-1 |
| 090 | Transmitter Mounting; Fill Fluid | A | Direct; silicone oil |
| 100 | Additional Option 1 | A | Not selected |
| 110 | Additional Option 2 | A | Not selected |