Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMP75 pressure transmitter

PMP75 pressure transmitter
Cerabar S PMP75
Configurable Models 4 models
The digital pressure transmitter adopts diaphragm sealing and is suitable for gases, vapors, and liquids.
Compare

Continuous / Liquids

Measuring Principle Absolute and gauge pressure
Characteristic / Application Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter
Long term stability
Minimum oil volume
Enhanced safety via self diagnostic functions
Secondary process barrier
Specialities Diagnostic functionalities
Different languages in software
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy 0,075% + influence of diaphragm seal
Long term stability 0,05% of URL/year
Ambient temperature -50°C...85°C
(-58°F...185°F)
Process temperature -70°C...400°C
(-94°F...752°F)
Process pressure / max. overpressure limit 1050bar (15,200psi)
Pressure measuring range 400 mbar...400 bar
(5.8 psi...6000 psi)
Main wetted parts Alloy C276
316L
Monel
Tantalum
PTFE-Foil
Process connection Threads
Flanges (DIN, ASME, JIS) with flush membrane
Tri-Clamp ISO02852
Hygienic connections
Max. measurement distance 7000m (22.966ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
Hygienic approvals 3A, EHEDG
Marine approval GL/ ABS
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Successor PMP71B
Application limits Measuring cell: Metal
welded
If pressurized, possibly
use differential pressure
meas-urement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure

Pressure

Measuring Principle Absolute and gauge pressure
Characteristic Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Available with diaphragm seals and advanced condensation resistance (Contite) functionality
Intuitive and clear wizard for
commissioning proof tests and
verification.
Supply voltage 4...20 mA HART
10,5…35V DC (Non Ex, Exd, Ex e):
Ex ia: 10,5...30V DC
PROFINET with Ethernet-APL
9,6…15V DC
PROFIBUS PA:
9...32 V DC (Non Ex, Ex d, Exe)
9…24V DC (Ex i)
Reference Accuracy Standard:
bis 0,05 %
Platinum:
bis 0,025 %
Long term stability 0,05 % von URL/ Jahr
0,07 % von URL/ 5 Jahre
0,10 % von URL/ 10 Jahre
Process temperature Standard:
-40°C…+125°C
Druckmittler:
-70°C...+250°C
Ambient temperature -40°C...85°C
(-58°F...185°F)
Measuring cell 100 mbar…100 bar
(1.5 psi…1500 psi)
relative/ absolute
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 5 mbar (0.075 psi)
Max. Turn down 100:1
Max. overpressure limit 400 bar (6.000 psi)
Process connection Thread:
G1/2...G2,MNPT1/2...MNPT2
Flange:
DN25…DN80,
NPS 1"…3"
Diaphragm seal
Process connection hygienic Tri-Clamp
DIN11851
DIN11864
NEUMO
Varivent
SMS
DRD
Anderson
Sanitary tank spud
Universal adapter
Material process membrane 316L
AlloyC
Material gasket None, diaphragm welded
Fill fluid Silicone oil,
Synthetic oil,
Vegetable oil,
High temperature oil,
Material housing Aluminum,
316L hygiene
Communication 4…20mA
4...20 mA HART
PROFIBUS PA
PROFINET mit Ethernet-APL
Bluetooth® drahtlose
Technologie und App (optional)
Certificates / Approvals ATEX, CAN/US, IEC Ex, JPN Ex,KC Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN10204-3.1
Hygienic approvals CoC ASME-BPE
cGMP
3A
EHEDG
Drinking water approvals Trinkwasserzulassungen
KTW
NSF
Specialities Heartbeat Technologie,
Bluetooth® Bedienung und Wartung mit der SmartBlue App,
LED- Modul,
RFID-TAG zur einfachen Identifikation,
"Plug and play" Funktionen,
HistoROM
Successor PMP63B

The Cerabar PMP75 digital pressure transmitter with metal diaphragm seal is mainly used in the process industry and the hygiene sector and can measure the pressure, level, volume and mass of liquids or gases. The transmitter is suitable for high-temperature and high-pressure applications with a temperature range from -70 to 400 °C. The measuring range is adjustable and can be set quickly, saving cost and time. The design complies with the IEC 61508 standard for SIL2/3 functional safety systems.

 

Advantages

A large number and variety of diaphragm seal materials and process connections

HistoROM®/M-DAT memory unit enables traceability of device settings and measured values

Developed and designed according to IEC 61508 for SIL2/3 safety systems (min., max., range)

Overload protection and function monitoring from the measuring diaphragm to the electronics

Quick setup menu for fast setting of basic commissioning parameters, menu-guided operation with advanced fault diagnostics; seamless, independent system integration (HART/PA/FF)

Hermetically sealed feedthrough provides a standard second line of defense

New TempC diaphragm minimizes temperature influence with short recovery time

 

Areas of application

Dual-compartment aluminum or stainless steel (316L) housing

 

Process connection: thread, flange or hygienic connection

Temperature range: -70 to +400°C (-94 to +752°F)

Pressure range: +100mbar to +400bar (+1.5 to +5,800psi)

Accuracy: ±0.075%

International explosion protection approval, WHG overflow protection, EN 10204-3.1, marine approval, 3A approval

Spare Parts & Accessories 92

92 spare parts · click to collapse
Order codeDescription
52022418key housingfor external operation consists of: push buttons, cover + screwsDetails
52022419key housingfor external operation consists of: push buttons, cover + screws colour: light greyDetails
52024110key housingfor external operation consists of: push button, cover + screws colour: dark greyDetails
52020760cable glandconsists of: cable gland M20 O-ring 18.72x2.62 VMQ Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020761cable entryconsists of: gasket 18.72x2.51 NBR adapter M20 > G1/2 O-ring 18.77x1.78 NBR Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020762plug connectorHarting plug set Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020763plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71111056Atmospheric compensation filter portConsists of: Vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: FMB50, FMB51, FMB52, FMB53, FMD71, FMD72, FMD76, FMD77, FMD78, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51, PMC71, PMD70, PMD75, PMP71, PMP75, PMP51, PMP55.Details
71219639Atmospheric compensation filter portConsists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 at B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.Details
52023572Sealing gasketProcess gasket for universal process adapter Deltapilot S DB50L/DB50S Levelflex M FMP41CDetails
52020432Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA not for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020433Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
71245247Aluminum coverMaterial: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details
71245249Aluminum coverMaterial: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details
71206965Stainless Steel CoverMaterial: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.Details
71206968Stainless Steel CoverMaterial: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details
52028310Stainless Steel CoverMaterial: 316L O-ring EPDM, FDA individual tested, EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
71245250CoverMaterial: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details
71002810cover with viewing windowMaterial: 316L Sight glass: mineral glass flat gasket VMQ, centering ring, screw approval 2,3,4,8,Q,W,7,8 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71002811cover with viewing windowMaterial: 316L Sight glass: Polycarbonat PC flat gasket VMQ, centering ring, screw approval A,F,R,S,U,1,6 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
4 models · click to collapse
All documents for this model
12 documents · click to expand
BA

Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions Chinese

HART Rev. 2022 68 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions Chinese

FOUNDATION-Fieldbus Rev. 1922 98 pages
Preview
BA

仪表功能描述 Cerabar S PMC71, PMP71/75 Deltabar S FMD76/77/78, PMD70/75 Deltapilot S FMB70 Chinese

Rev. 1413 168 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions English

HART Rev. 2022 68 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions English

FOUNDATION-Fieldbus Rev. 1922 98 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 PROFIBUS PA (V 04.01.zz) Operating Instructions English

PROFIBUS-PA Rev. 1922 86 pages
Preview
BA

Cerabar S / Deltabar S / Deltapilot S HART V02.30.zz Description of Instrument Functions English

HART Rev. 1816 148 pages
Preview
BA

Cerabar S / Deltabar S / Deltapilot S, Description of device functions FOUNDATION Fieldbus V 04.00.zz English

FOUNDATION-Fieldbus Rev. 1716 258 pages
Preview
BA

Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz English

PROFIBUS-PA Rev. 1616 170 pages
Preview
BA

Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA English

PROFIBUS-PA Rev. 0510 174 pages
Preview
TI

TI Cerabar S PMC71, PMP71, PMP75 Chinese

Rev. 3624 128 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Gauge and Absolute Pressure — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Gauge and Absolute Pressure — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.