Technical Data
CompareContinuous / Liquids
| Measuring Principle | Absolute and gauge pressure |
| Characteristic / Application | Digital transmitter with piezoresistive sensor and diaphragm seal Modular transmitter Long term stability Minimum oil volume Enhanced safety via self diagnostic functions Secondary process barrier |
| Specialities | Diagnostic functionalities Different languages in software |
| Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC |
| Accuracy | 0,075% + influence of diaphragm seal |
| Long term stability | 0,05% of URL/year |
| Ambient temperature | -50°C...85°C (-58°F...185°F) |
| Process temperature | -70°C...400°C (-94°F...752°F) |
| Process pressure / max. overpressure limit | 1050bar (15,200psi) |
| Pressure measuring range | 400 mbar...400 bar (5.8 psi...6000 psi) |
| Main wetted parts | Alloy C276 316L Monel Tantalum PTFE-Foil |
| Process connection | Threads Flanges (DIN, ASME, JIS) with flush membrane Tri-Clamp ISO02852 Hygienic connections |
| Max. measurement distance | 7000m (22.966ft) H2O |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC |
| Safety approvals | SIL |
| Design approvals | EN 10204-3.1 NACE MR0175, MR0103 |
| Hygienic approvals | 3A, EHEDG |
| Marine approval | GL/ ABS |
| Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
| Successor | PMP71B |
| Application limits | Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |
Pressure
| Measuring Principle | Absolute and gauge pressure |
| Characteristic | Digital transmitter with piezoresistive sensor and diaphragm seal Modular transmitter Long term stability Enhanced safety via self diagnostic functions Available with diaphragm seals and advanced condensation resistance (Contite) functionality Intuitive and clear wizard for commissioning proof tests and verification. |
| Supply voltage | 4...20 mA HART 10,5…35V DC (Non Ex, Exd, Ex e): Ex ia: 10,5...30V DC PROFINET with Ethernet-APL 9,6…15V DC PROFIBUS PA: 9...32 V DC (Non Ex, Ex d, Exe) 9…24V DC (Ex i) |
| Reference Accuracy | Standard: bis 0,05 % Platinum: bis 0,025 % |
| Long term stability | 0,05 % von URL/ Jahr 0,07 % von URL/ 5 Jahre 0,10 % von URL/ 10 Jahre |
| Process temperature | Standard: -40°C…+125°C Druckmittler: -70°C...+250°C |
| Ambient temperature | -40°C...85°C (-58°F...185°F) |
| Measuring cell | 100 mbar…100 bar (1.5 psi…1500 psi) relative/ absolute |
| Smallest calibratable span | 5 mbar (0.075 psi) |
| Vacuum resistance | 5 mbar (0.075 psi) |
| Max. Turn down | 100:1 |
| Max. overpressure limit | 400 bar (6.000 psi) |
| Process connection | Thread: G1/2...G2,MNPT1/2...MNPT2 Flange: DN25…DN80, NPS 1"…3" Diaphragm seal |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864 NEUMO Varivent SMS DRD Anderson Sanitary tank spud Universal adapter |
| Material process membrane | 316L AlloyC |
| Material gasket | None, diaphragm welded |
| Fill fluid | Silicone oil, Synthetic oil, Vegetable oil, High temperature oil, |
| Material housing | Aluminum, 316L hygiene |
| Communication | 4…20mA 4...20 mA HART PROFIBUS PA PROFINET mit Ethernet-APL Bluetooth® drahtlose Technologie und App (optional) |
| Certificates / Approvals | ATEX, CAN/US, IEC Ex, JPN Ex,KC Ex, INMETRO, NEPSI, UK Ex |
| Safety approvals | SIL |
| Design approvals | EN10204-3.1 |
| Hygienic approvals | CoC ASME-BPE cGMP 3A EHEDG |
| Drinking water approvals | Trinkwasserzulassungen KTW NSF |
| Specialities | Heartbeat Technologie, Bluetooth® Bedienung und Wartung mit der SmartBlue App, LED- Modul, RFID-TAG zur einfachen Identifikation, "Plug and play" Funktionen, HistoROM |
| Successor | PMP63B |
The Cerabar PMP75 digital pressure transmitter with metal diaphragm seal is mainly used in the process industry and the hygiene sector and can measure the pressure, level, volume and mass of liquids or gases. The transmitter is suitable for high-temperature and high-pressure applications with a temperature range from -70 to 400 °C. The measuring range is adjustable and can be set quickly, saving cost and time. The design complies with the IEC 61508 standard for SIL2/3 functional safety systems.
Advantages
A large number and variety of diaphragm seal materials and process connections
HistoROM®/M-DAT memory unit enables traceability of device settings and measured values
Developed and designed according to IEC 61508 for SIL2/3 safety systems (min., max., range)
Overload protection and function monitoring from the measuring diaphragm to the electronics
Quick setup menu for fast setting of basic commissioning parameters, menu-guided operation with advanced fault diagnostics; seamless, independent system integration (HART/PA/FF)
Hermetically sealed feedthrough provides a standard second line of defense
New TempC diaphragm minimizes temperature influence with short recovery time
Areas of application
Dual-compartment aluminum or stainless steel (316L) housing
Process connection: thread, flange or hygienic connection
Temperature range: -70 to +400°C (-94 to +752°F)
Pressure range: +100mbar to +400bar (+1.5 to +5,800psi)
Accuracy: ±0.075%
International explosion protection approval, WHG overflow protection, EN 10204-3.1, marine approval, 3A approval
Spare Parts & Accessories 92
92 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52022418 | key housingfor external operation consists of: push buttons, cover + screws | Details |
| 52022419 | key housingfor external operation consists of: push buttons, cover + screws colour: light grey | Details |
| 52024110 | key housingfor external operation consists of: push button, cover + screws colour: dark grey | Details |
| 52020760 | cable glandconsists of: cable gland M20 O-ring 18.72x2.62 VMQ Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
| 52020761 | cable entryconsists of: gasket 18.72x2.51 NBR adapter M20 > G1/2 O-ring 18.77x1.78 NBR Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
| 52020762 | plug connectorHarting plug set Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
| 52020763 | plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
| 71111056 | Atmospheric compensation filter portConsists of: Vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: FMB50, FMB51, FMB52, FMB53, FMD71, FMD72, FMD76, FMD77, FMD78, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51, PMC71, PMD70, PMD75, PMP71, PMP75, PMP51, PMP55. | Details |
| 71219639 | Atmospheric compensation filter portConsists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 at B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. | Details |
| 52023572 | Sealing gasketProcess gasket for universal process adapter Deltapilot S DB50L/DB50S Levelflex M FMP41C | Details |
| 52020432 | Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA not for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
| 52020433 | Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 | Details |
| 71245247 | Aluminum coverMaterial: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. | Details |
| 71245249 | Aluminum coverMaterial: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. | Details |
| 71206965 | Stainless Steel CoverMaterial: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. | Details |
| 71206968 | Stainless Steel CoverMaterial: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. | Details |
| 52028310 | Stainless Steel CoverMaterial: 316L O-ring EPDM, FDA individual tested, EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 | Details |
| 71245250 | CoverMaterial: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. | Details |
| 71002810 | cover with viewing windowMaterial: 316L Sight glass: mineral glass flat gasket VMQ, centering ring, screw approval 2,3,4,8,Q,W,7,8 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
| 71002811 | cover with viewing windowMaterial: 316L Sight glass: Polycarbonat PC flat gasket VMQ, centering ring, screw approval A,F,R,S,U,1,6 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70 | Details |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playManuals & Documents 12
All documents for this model12 documents · click to expand
Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions Chinese
Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions Chinese
仪表功能描述 Cerabar S PMC71, PMP71/75 Deltabar S FMD76/77/78, PMD70/75 Deltapilot S FMB70 Chinese
Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions English
Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions English
Cerabar S PMC71, PMP71, PMP75 PROFIBUS PA (V 04.01.zz) Operating Instructions English
Cerabar S / Deltabar S / Deltapilot S HART V02.30.zz Description of Instrument Functions English
Cerabar S / Deltabar S / Deltapilot S, Description of device functions FOUNDATION Fieldbus V 04.00.zz English
Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz English
Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA English
TI Cerabar S PMC71, PMP71, PMP75 Chinese
TI 焊接接头、过程转接头和法兰 Chinese
Case Studies
Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.
What We Did
We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.
Food & Beverage · Gauge and Absolute Pressure — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.
Delivery Approach
Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.
Implementation
The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.
Power & Energy · Gauge and Absolute Pressure — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.
Solution
The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.