Product family: Cerabar S PMP75
Cerabar S PMP75In Stock (2)
Endress+Hauser PMP75-ABT2H22B3AAA
Cerabar S PMP75;Approval Non-hazardous area;Output/Operating 4-20mA HART; inside + LCD;Housing/Cover Sealing/Cable Entry T17 316L hyg. IP66/68 NEMA6P;EPDM;NPT1/2 thread, T17 = side cover, hygiene;Sensor Range/Sensor Overload Limit 1bar/100kPa/15psi abs; 10bar/1MPa/150psi;Calibration/Unit Sensor range; kPa/MPa;Membrane Material AlloyC276;Process Connection DN50 PN10-40 B1, 316L, flush mount, flange EN1092-1;Transmitter Mounting/Fill Fluid Direct; silicone oil;Additional Option

Order Code:PMP75-ABT2H22B3AAA

Name:Cerabar S PMP75

Configuration

CodeNameOrderSpecification
010ApprovalANon-hazardous area
020Output; OperatingB4-20mA HART; inside + LCD
030Housing; Cover Sealing; Cable EntryTT17 316L hyg. IP66/68 NEMA6P;EPDM;NPT1/2 thread, T17 = side cover, hygiene
040Sensor Range; Sensor Overload Limit2H1bar/100kPa/15psi abs; 10bar/1MPa/150psi
050Calibration; Unit2Sensor range; kPa/MPa
060Membrane Material2AlloyC276
070Process ConnectionB3DN50 PN10-40 B1, 316L, flush mount, flange EN1092-1
090Transmitter Mounting; Fill FluidADirect; silicone oil
100Additional Option 1ANot selected
110Additional Option 2ANot selected

Configuration Explained

This is a PMP75 digital pressure transmitter, diaphragm seal design, measures gases, liquids and steam, for non-hazardous areas, 4-20mA HART output, internal push buttons with LCD, T17 stainless steel housing, NPT1/2, IP66/68, absolute pressure range 1 bar, calibrated in kPa/MPa, Hastelloy C diaphragm, corrosion resistant, process connection DN50 PN10-40 B1 flange, 316L flush, suitable for absolute pressure measurement of media prone to clogging and crystallisation.