Technical Data
ComparePhysical medium properties
| Measuring Principle | |
| Measuring method | Capacitive- conductive |
| Application | Continuous inline measurement of build-up and liquid conductivity |
| Supply voltage | 10…30 VDC IO-Link: 18…30 VDC |
| Measuring range | Conductivity: 0 µS/ cm...100 mS/ cm Build-up thickness: 0 mm…10 mm |
| Accuracy | Build-up: <= 1% of measuring range Conductivity: 0...2 mS/ cm: <= 5% of reading 2...20 mS/ cm: <= 7% of reading 20...50 mS/ cm: <= 10% of reading 50...100 mS/ cm: <= 15% of reading |
| Ambient temperature | -40°C…+70°C (-40°F...+158°F) |
| Process temperature | -20°C…+100°C (-4°F...+212°F) +150°C (+302°F) for 1h |
| Process pressure | Vacuum...25 bar (Vacuum...362.5 psi) |
| Output / communication | 4...20 mA Frequency IO-Link |
| Connection | Threads G1", G3/4", M24, Tri-Clamp ISO2852, DIN11851 |
| Ex certification | No Ex certificates CSA C/US General Purpose |
| Certificates, declarations and approvals | EN10204- 3.1 EHEDG 3-A EG1935/2004 CRN approval |
| Options | Customer specific configuration Cleaned from oil and grease Surface roughness test Welding- and process adapters |
Liquitrend QMW43 is specially designed for the food & beverage industry, helping customers ensure product safety, improve product quality and increase equipment availability. Combining the conductivity and capacitance measuring principles, its unique, reliable method of measuring the thickness and conductivity of buildup deposits helps you make the right decisions.
Advantages
-
Reliable, repeatable, high-precision measurement of buildup thickness and conductivity, independent of the medium type
-
Perfect combination of conductivity and capacitance measuring principles; the device automatically and precisely detects the measuring mode and switches modes automatically
-
Verify the cleaning status without opening the tank
-
Stainless steel sensor, compact structure, flush-mounted, direct view of the condition at critical process points in pipes or tanks
-
Plug-and-play, simple commissioning, no presetting required
-
Hygienic design with traceable materials
-
IO-Link digital communication available
Application
-
Optimize cleaning results, monitor mixing uniformity, identify media, suitable for liquids, suspensions, pasty media, etc.
-
Installed on storage tanks, mixing tanks, process vessels with or without agitators, pipes and peripheral equipment
-
Process connections: threaded and hygienic connections
-
Sensor design: flush-mounted; surface finish: Ra < 0.76μm
-
Temperature: -20...+100°C (-4...+212°F); CIP/SIP cleaning: withstands up to 150°C (302°F) for no more than 1 hour
-
Certificates and declarations: 3A, FDA, EHEDG and EG1935/2005, EN10204-3.1
Spare Parts & Accessories 57
57 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52006263 | Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰 | Details |
| 52010285 | M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母 | Details |
| 52018763 | Cable with connector | Cable 4x0.34, box M12, 316L, LED, 9适用于M12插头,集成LED指示 带5m电缆 PVC 材质 316L锁紧螺母 针对卫生型应用 | Details |
| 52024216 | Cable socketM12x1 plug 5m cable PVC, 316L lock Especially for sanitary applications | Details |
| 52010156 | socket wrenchLiquiphant T FTL20/FTL20H | Details |
| 52014048 | O-ringProcess gasket for process connections G1 | Details |
| 71185027 | O-ringProcess gasket DIN7603-A. Usage: process connection, FMI51, FMI52, FTI51, FTI52, FMP50, FMP51, FMP56, FMR43, FMR60B, FMR62, QMW43, FTL31, FTL33, FTL41, FTW23, FTW33, FTL50, FTL50H, FTL51, FTL51B, FTL80, FTL81. | Details |
| 52001051 | Process connection | Weld-in G1, d=60, 316L齐平安装式过程连接 FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" 材质: 316L 密封: 硅橡胶 O-ring | Details |
| 52001052 | weld socketFlush mount process connection FTL50/FTL50H "GQ2" Material: 316L Seal: Silicone O-ring | Details |
| 52011896 | Welding socket, G1, d=60, 3.1 material certificateFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52011897 | weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL41, FTL43, FTL50, FTL50H, FTL51B, FTL63, FTL80, QMW43, TMR35. | Details |
| 52018765 | weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ", FMI51, FTI51 "GQJ" Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52028295 | weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ" w/o flange Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 71041381 | Welded boss M24 D65Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: EPDM O-ring FDA, EHEDG, 3-A compliant. Usage: FMP53, FTL33, FTW23, FTW33, PMP23, PTP33B, QMW43. | Details |
| 71041383 | Welding boss M24 D65, 3.1 material certificateFlush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: EPDM O-ring. FDA, EHEDG, 3-A compliant. Usage: FMP53, FTL33, FTW23, FTW33, PMP23, PTP33B, QMW43. | Details |
| 71093129 | weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL20H, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51B, FTL51H, FTL63, FTL80, FTL81, FTL260, PMP135, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43. | Details |
| 71258355 | Stainless steel connector | Weld-in adapter G3/4 d=50, 316LFlush mount process connection. For vessel-mounting. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23, FTW33, FMI51, FTI51, QMW43, 11371. Usage: TMR35. | Details |
| 71258357 | Process connection|Weld-in G3/4, d=29, 316LFlush mount process connection. For pipe-mounting. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23, FTW33, QMW43. | Details |
| 71258358 | Weld socket G1, d=53, 316LFlush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51H, FTL51B, FTL63, FTL80, FTL81, FTL260, FTL330H, FTL330L, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43. | Details |
| 52021717 | O-ringfor weld-in adapter G3/4 D=50 316L Liquiphant T FTL20H | Details |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · conductive — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on conductive and the core task is conductive point-level and leakage detection.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So conductive cannot be specified generically — it calls for choosing electrode material and insulation by conductivity and temperature.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing electrode material and insulation by conductivity and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is no moving parts, giving fast pump and valve interlock response.
Food & Beverage · conductive — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted conductive properly configured on the existing plant, with the aim of conductive point-level and leakage detection.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the conductive configuration has to involve choosing electrode material and insulation by conductivity and temperature.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing electrode material and insulation by conductivity and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is no moving parts, giving fast pump and valve interlock response, and the readings are now used for process tuning.
Chemical & Pharmaceutical · conductive — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was conductive point-level and leakage detection.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing electrode material and insulation by conductivity and temperature.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing electrode material and insulation by conductivity and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — no moving parts, giving fast pump and valve interlock response, with routine maintenance falling noticeably.
Power & Energy · conductive — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from conductive, focusing on conductive point-level and leakage detection.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The conductive specification must therefore cover choosing electrode material and insulation by conductivity and temperature.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing electrode material and insulation by conductivity and temperature, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — no moving parts, giving fast pump and valve interlock response, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserLiquipoint T FTW31
Endress+HauserNivotester FTW325
Endress+HauserLiquipoint FTW23
Endress+HauserLiquipoint FTW33
Endress+HauserOne rod probe 11371
Endress+HauserLiquipoint T FTW32
Endress+HauserOne rod probe 11375Z
Endress+Hauser