Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

QMW43 电导传感器

QMW43  电导传感器

Liquitrend QMW43

The Liquitrend QMW43 is developed for the food and beverage industry to help customers to ensure product safety, improve quality and increase the availability of installations. Base your decisions on the unique and reliable measurement of buildup thickness and conductivity via the combination of conductive and capacitive measuring modes.
Compare

Physical medium properties

Measuring Principle
Measuring method Capacitive- conductive
Application Continuous inline measurement of build-up and liquid conductivity
Supply voltage 10…30 VDC
IO-Link: 18…30 VDC
Measuring range Conductivity:
0 µS/ cm...100 mS/ cm
Build-up thickness:
0 mm…10 mm
Accuracy Build-up:
<= 1% of measuring range
Conductivity:
0...2 mS/ cm: <= 5% of reading
2...20 mS/ cm: <= 7% of reading
20...50 mS/ cm: <= 10% of reading
50...100 mS/ cm: <= 15% of reading
Ambient temperature -40°C…+70°C (-40°F...+158°F)
Process temperature -20°C…+100°C
(-4°F...+212°F)
+150°C (+302°F) for 1h
Process pressure Vacuum...25 bar
(Vacuum...362.5 psi)
Output / communication 4...20 mA
Frequency
IO-Link
Connection Threads G1", G3/4", M24,
Tri-Clamp ISO2852, DIN11851
Ex certification No Ex certificates
CSA C/US General Purpose
Certificates, declarations and approvals EN10204- 3.1
EHEDG
3-A
EG1935/2004
CRN approval
Options Customer specific configuration
Cleaned from oil and grease
Surface roughness test
Welding- and process adapters

Liquitrend QMW43 is specially designed for the food & beverage industry, helping customers ensure product safety, improve product quality and increase equipment availability. Combining the conductivity and capacitance measuring principles, its unique, reliable method of measuring the thickness and conductivity of buildup deposits helps you make the right decisions.


Advantages
Reliable, repeatable, high-precision measurement of buildup thickness and conductivity, independent of the medium type
Perfect combination of conductivity and capacitance measuring principles; the device automatically and precisely detects the measuring mode and switches modes automatically
Verify the cleaning status without opening the tank
Stainless steel sensor, compact structure, flush-mounted, direct view of the condition at critical process points in pipes or tanks
Plug-and-play, simple commissioning, no presetting required
Hygienic design with traceable materials
IO-Link digital communication available


Application
Optimize cleaning results, monitor mixing uniformity, identify media, suitable for liquids, suspensions, pasty media, etc.
Installed on storage tanks, mixing tanks, process vessels with or without agitators, pipes and peripheral equipment
Process connections: threaded and hygienic connections
Sensor design: flush-mounted; surface finish: Ra < 0.76μm
Temperature: -20...+100°C (-4...+212°F); CIP/SIP cleaning: withstands up to 150°C (302°F) for no more than 1 hour
Certificates and declarations: 3A, FDA, EHEDG and EG1935/2005, EN10204-3.1

 

E+H Product Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the boxes below (max. three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductive Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Conductive Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductive Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Conductive Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.