Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

RIA16 Field Indicator

RIA16 Field Indicator
Field Indicator RIA16
Configurable Models 1 models
The indicator shows the measured signal on the large, backlit display. A bar graph indicates the value graphically for a quick process overview. An editable plain text field displays further information like engineering unit or TAG. Limit value infringement is also signalized and an open collector can be switched. The indicator is powered directly from the 4...20 mA loop and doesn't need a separate power supply. For applications in hazardous areas the device is available with Ex approvals.
Compare

Process indicator & control units

Measuring Principle Loop powered indicators
Measuring principle Loop-powered field indicator
Function Display
Display LCD 26 mm (1.02")
5-digit
Bargraph
Plain text display
Power Supply Loop powered
Input 1 x analogue 4...20 mA
Output 1 x open collector
Software functions Not defined
Certificates ATEX Ex ib[ia]
CSA General Purpose
CSA IS, NI
FM IS, NI
EAC Ex ib[ia]
IECEx Ex ib[ia]
NEPSI Ex ib[ia]
UK Ex ib [ia Ga]
IND Ex
PESO Ex
marine certificate
SIL Not defined
Panel mounting field

The indicator's large backlit display shows the measured value; an optional bar graph visualizes the measured value for a faster process overview. Editable plain text can display engineering units or TAG information. If a limit value is exceeded, a signal is output that opens the collector. The indicator requires no separate power supply and can be powered directly by the 4...20 mA loop. The device is Ex-certified and suitable for hazardous areas.

Advantages

  • 4...20 mA measured value display

  • 5-digit measured value display including dimension, bar graph and backlighting

  • No external power supply required

  • Version: glass-fiber reinforced plastic or aluminum, suitable for Ex applications

  • Simple 3-key operation; or via FieldCare PC software; or via the setup box, without power supply

  • International approvals; marine approval

  • Allows the HART® transmission protocol to pass through freely

Application

The display unit is housed in a field instrument housing with a microcontroller and LC backlit display. The display of measuring range, decimal point and offset can be easily configured via 3 keys after opening the housing, or on a computer using the FieldCare PC software.

Spare Parts & Accessories 9

9 spare parts · click to collapse
Order codeDescription
RIA16X-RIA16 spare parts RIA16X-Enquire
RIA16X-RIA16 spare parts RIA16X-Enquire
RIA16X-RIA16 spare parts RIA16X-Enquire
RIA16X-RIA16 spare parts RIA16X-Enquire
RIA16X-RIA16 spare parts RIA16X-Enquire
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
RK01-System component RK01Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
XPRFID-Spare RFID TAGConsists of: RFID TAG, fixing wire, crimp sleeve.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

1 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA RIA16 Chinese

Rev. 0623 32 pages
Preview
BA

BA RIA16 English

Rev. 0623 36 pages
Preview
BA

Operating instructions RIA16 English

Rev. 0212 32 pages
Preview
TI

TI RIA16 Chinese

Rev. 0623 8 pages
Preview
TI

TI RIA16 English

Rev. 0623 12 pages
Preview
TI

Technical Information RIA16 English

Rev. 0213 10 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Process Measuring and Control Instrument — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Process Measuring and Control Instrument, focusing on measurement, control and recording for process loops.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Process Measuring and Control Instrument specification must therefore cover configured by input type, loop count and communication.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by input type, loop count and communication, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — configured on site, cutting back-and-forth during system commissioning, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Process Measuring and Control Instrument — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Process Measuring and Control Instrument; the focus is measurement, control and recording for process loops.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by input type, loop count and communication.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on configured by input type, loop count and communication, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means configured on site, cutting back-and-forth during system commissioning, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Process Measuring and Control Instrument — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Process Measuring and Control Instrument and the core task is measurement, control and recording for process loops.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Process Measuring and Control Instrument cannot be specified generically — it calls for configured by input type, loop count and communication.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by input type, loop count and communication, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is configured on site, cutting back-and-forth during system commissioning.

Power & Energy

Power & Energy · Process Measuring and Control Instrument — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Process Measuring and Control Instrument properly configured on the existing plant, with the aim of measurement, control and recording for process loops.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Process Measuring and Control Instrument configuration has to involve configured by input type, loop count and communication.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant configured by input type, loop count and communication, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is configured on site, cutting back-and-forth during system commissioning, and the readings are now used for process tuning.