Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

RIA46 Field Meter with Control Unit

RIA46 Field Meter with Control Unit
Field Meter with Control Unit RIA46
Configurable Models 2 models
Analog measured values are indicated, evaluated and calculated by the field indicator. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package "differential pressure" allows the quick and easy commissioning for differential pressure applications.
Compare

Process indicator & control units

Measuring Principle Indicators with control unit
Measuring principle Field meter with control unit
Function Display
Loop Power Supply
Transmitter Functionality
Barrier
Signal Isolation
Calculation
Limit Alarm
Display Multicolor backlight LCD
White/black/yellow
Bargraph
Unit
TAG
Alarm warning in plain text
Power Supply 20...250V AC/DC
Input 2 x universal (U, I, R, RTD, TC)
Output 2 x analogue output (I, U) 1 x loop power supply
Software functions Linearization
Minimum value per channel
Maximum value per channel
Calculation
Band value monitoring
Certificates ATEX [Ex ia]
CSA General Purpose
CSA AIS, NI
FM AIS, NI
UK [Ex ia Ga] IIC, [Ex ia Da]
SIL 2
Panel mounting field

Analog measured values are displayed, evaluated and calculated by the process meter. Two-wire sensors can be loop-powered. The universal input can connect current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Process signals can be transmitted via the analog output. A color change in the event of a fault supports alarm recognition. The built-in “differential pressure” application package enables fast and simple commissioning of different pressures.

  • Advantages

  • 5-digit 7-segment measured value display with LC backlighting

  • 1 or 2 universal inputs

  • 2 relays (optional)

  • Min/max value memory

  • 1 or 2 calculated values and linearization tables

  • Digital status output (open collector)

  • SIL2 approval (optional)

  • Application areas

  • The RIA46 panel meter provides display functions for analog input of process and status signals, analog or digital signal output and interface configuration. The connected sensors can be powered by the integrated LPS. All measured and calculated values can be used as independent signal sources for display, output, transmission and interface communication.

  • Plant and equipment engineering construction

  • Process control

  • Signal commissioning and conversion

Spare Parts & Accessories 9

9 spare parts · click to collapse
Order codeDescription
RIA46T-CPU board RIA46TEnquire
71084277plug connectorDetails
RIA46X-Spare PartsEnquire
RIA46X-Spare PartsEnquire
RIA46X-Spare PartsEnquire
RIA46X-Spare PartsEnquire
RIA46X-Spare PartsEnquire
RK01-System component RK01Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Accessories / Spare parts

Source:Endress+Hauserpublic information from the website

2 models · click to collapse
All documents for this model
5 documents · click to expand
BA

BA RIA46 Chinese

Rev. 0525 68 pages
Preview
BA

BA RIA46 English

Rev. 0525 72 pages
Preview
BA

Operating instructions RIA46 English

Rev. 0111 62 pages
Preview
TI

TI RIA46 Chinese

Rev. 0825 12 pages
Preview
TI

TI RIA46 English

Rev. 0825 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Process Measuring and Control Instrument — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Process Measuring and Control Instrument, focusing on measurement, control and recording for process loops.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Process Measuring and Control Instrument specification must therefore cover configured by input type, loop count and communication.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by input type, loop count and communication, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — configured on site, cutting back-and-forth during system commissioning, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Process Measuring and Control Instrument — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Process Measuring and Control Instrument; the focus is measurement, control and recording for process loops.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by input type, loop count and communication.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on configured by input type, loop count and communication, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means configured on site, cutting back-and-forth during system commissioning, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Process Measuring and Control Instrument — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Process Measuring and Control Instrument and the core task is measurement, control and recording for process loops.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Process Measuring and Control Instrument cannot be specified generically — it calls for configured by input type, loop count and communication.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by input type, loop count and communication, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is configured on site, cutting back-and-forth during system commissioning.

Power & Energy

Power & Energy · Process Measuring and Control Instrument — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Process Measuring and Control Instrument properly configured on the existing plant, with the aim of measurement, control and recording for process loops.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Process Measuring and Control Instrument configuration has to involve configured by input type, loop count and communication.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant configured by input type, loop count and communication, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is configured on site, cutting back-and-forth during system commissioning, and the readings are now used for process tuning.