Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

RIA45 Panel Meter with Control Unit

RIA45 Panel Meter with Control Unit
Panel Meter with Control Unit RIA45
Configurable Models 20 models
Analog measured values are indicated, evaluated and calculated by the process meter. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package "differential pressure" allows the quick and easy commissioning for differential pressure applications.
Compare

Process indicator & control units

Measuring Principle Indicators with control unit
Measuring principle Process meter with control unit
Function Display
Loop power supply
Transmitter functionality
Barrier
Signal isolation
Calculation
Limit alarm
Display Multicolor backlight LCD
White/black/yellow
Bargraph
Unit
TAG
Alarm warning in plain text
Power Supply 20...250V AC/DC
Input 2 x universal (U, I, R, RTD, TC)
Output 1 x loop power supply
Software functions Linearization
Minimum value per channel
Maximum value per channel
Calculation
Band value monitoring
Certificates ATEX [Ex ia]
CSA General Purpose
CSA AIS, NI
FM AIS, NI
UK [Ex ia Ga], [Ex ia Da]
marine certificate
SIL 2
Panel mounting panel mounting

Analog measured values are displayed, evaluated and calculated by the process meter. Two-wire sensors can be powered via the loop. The universal input can connect current, voltage, RTDs and TCs. Limit values can be monitored and relays switched. Process signals can be transmitted via the analog output. A color change in the event of a fault supports alarm detection. The built-in “differential pressure” application package enables fast and simple commissioning for different pressures.

Benefits

  • 5-digit, 7-segment measured value display with LC backlighting

  • 1 or 2 universal inputs

  • 2 relays (optional)

  • Min/max value storage

  • 1 or 2 calculated values and linearization table

  • Digital status output (open collector)

  • SIL2 certification (optional); marine approval

Applications

  • The RIA45 panel meter provides display functions, analog input of process and status signals, and analog or digital signal output with interface configuration. The connected sensors can be powered via the integrated LPS. All measured and calculated values can be used as signal sources for display, output, transmission and interface communication.

  • Plant and equipment engineering

  • Control rooms and control cabinets

  • Laboratories

  • Process recording and monitoring

  • Process control

  • Signal commissioning and conversion

Spare Parts & Accessories 17

17 spare parts · click to collapse
Order codeDescription
RIA45X-Spare part RIA45X-Enquire
RIA45T-CPU Board RIA45TEnquire
RIA45X-Spare part RIA45X-Enquire
71123475terminal blockfor power supply RSG30: from unit No. DB001004267 orange coloured connectorDetails
71296182terminal blockDetails
RIA45X-Spare part RIA45X-Enquire
710373504-pin terminalMemograph M for analog output (on digital I/O board) RIA45 for analog input non Ex (terminal x1,x2,x3,x4 + x5,x6,x7,x8)Details
71074564terminal boardAnalog input Ex, blue upstairs (terminal x1, x2, x3, x4)Details
71074567terminal boardAnalog input Ex, blue, down (terminal x5, x6, x7, x8)Details
71075062terminal plug connectorTerminal analog output 1 + status output (DI11,DI12,O15)Details
RIA45X-Spare part RIA45X-Enquire
71037408threaded terminalFor relay 1+2 (change-over contact).Details
71075063terminal plug connectorAnalog output 2 (O25, O26)Details
71081257Pipe fixing bolt 105 mmDetails
71069920clamp-on coverDetails
RK01-System component RK01Enquire
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: Endress+Hauserpublic information from the website

26 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA RIA45 Chinese

Rev. 0825 68 pages
Preview
BA

BA RIA45 English

Rev. 0825 72 pages
Preview
TI

TI RIA45 Chinese

Rev. 0725 16 pages
Preview
TI

TI RIA45 English

Rev. 0725 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Process Measuring and Control Instrument — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Process Measuring and Control Instrument, focusing on measurement, control and recording for process loops.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Process Measuring and Control Instrument specification must therefore cover configured by input type, loop count and communication.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by input type, loop count and communication, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — configured on site, cutting back-and-forth during system commissioning, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Process Measuring and Control Instrument — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Process Measuring and Control Instrument; the focus is measurement, control and recording for process loops.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by input type, loop count and communication.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on configured by input type, loop count and communication, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means configured on site, cutting back-and-forth during system commissioning, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Process Measuring and Control Instrument — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Process Measuring and Control Instrument and the core task is measurement, control and recording for process loops.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Process Measuring and Control Instrument cannot be specified generically — it calls for configured by input type, loop count and communication.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by input type, loop count and communication, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is configured on site, cutting back-and-forth during system commissioning.

Power & Energy

Power & Energy · Process Measuring and Control Instrument — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Process Measuring and Control Instrument properly configured on the existing plant, with the aim of measurement, control and recording for process loops.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Process Measuring and Control Instrument configuration has to involve configured by input type, loop count and communication.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant configured by input type, loop count and communication, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is configured on site, cutting back-and-forth during system commissioning, and the readings are now used for process tuning.