Technical Data
CompareData Acquisition
| Measuring Principle | Electronic Data Acquisition |
| Functions | "Secure data recording and signal analysis Visualization Integrated web server for device set-up E-Mail notification 100 ms scan rate Modular design for simple expansion Data readout and processing via Field Data Manager Software OPC server for indication of instantaneous values (optional) |
| Maximal input | "12 Analog (U, I, TC, RTD, frequency, pulse) 6 Digital" |
| Maximal output | 6 Relays 1 Transmitter power supply´ |
| Interface | RS232/485 (optional) Ethernet USB Modbus RTU Slave (optional) Modbus TCP Slave (optional) |
| Storage/Recording | Internal memory SD card USB flash drive |
| Display | TFT 5.7" colour graphic display |
| Housing | Panel desktop housing field housing |
| Power supply | 100…230 V AC +/-10% 24V (-10%, +15%) AC/DC |
| Certification | UL CSA GP |
| Software package | Mathematics |
Data Manager & Data Logger
| Measuring Principle | Data manager |
| Measuring principle | Universal Graphic Data Manager |
| Function | Secure data recording made easy - Monitor, visualize, record and communicate process values - every measurement value counts! |
| Input | 12 analog (max) (U, I, TC, RTD, frequency, pulse) 6 digital (max) |
| Output | 6 relays (max) 1 transmitter power supply |
| Interface | RS232/485 (optional) Ethernet USB Modbus RTU/TCP Slave (optional) |
| Storage/Recording | internal memory SD card USB flash drive |
| Display | TFT 5.7" colour graphic display |
| Housing | panel mounting desktop housing field housing |
| Certificates | UL recognized Non-hazardous area + KC marking |
| Software package | mathematics |
Safe, complete recording and visualization of all processes. The requirements for process monitoring and data recording are becoming increasingly complex. Because every measured value matters, the universal graphic data manager Ecograph T RSG35 records, visualizes and monitors all analog or digital input signals. The device is easy to use while also saving costs and simplifying data acquisition. System integration is simple thanks to various communication protocols.
Benefits
Versatile: up to 12 universal input channels for recording a wide range of measurement signals
Clear layout: 5.7" TFT display shows up to 4 groups of measured values in digital, bar and curve form
Safe: reliable data archiving using internal memory and a separate SD card
Simple: intuitive operation via on-site navigation (frame-by-frame) or via the built-in web server on a PC with a user-friendly interface
All-in-one: easy installation, saving space and money
System-capable: common interfaces such as Ethernet, RS232/RS485 (modem) and USB; optional Modbus RTU/TCP slave function
Informative: sends e-mail alarms and limit-value notifications
Application areas
The Ecograph T provides the best solution for many processes and industries, for example:
Quantity and quality monitoring in the water and wastewater industry;
Temperature monitoring in metal processing;
Process monitoring in power stations;
Display and recording of key parameters during production cycles;
Tank farm and level monitoring.
Source: public information from the Endress+Hauser website
Measuring principle video
Click to playSpare Parts & Accessories 23
23 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPR0007- | Spare parts kit, display, RSG35 XPR0007 | Enquire |
| 71155329 | RSG35 enclosure | Details |
| XPR0007- | Spare parts kit, display, RSG35 XPR0007 | Enquire |
| XPR0007- | Spare parts kit, display, RSG35 XPR0007 | Enquire |
| XPR0007- | Spare parts kit, display, RSG35 XPR0007 | Enquire |
| 71123475 | terminal blockfor power supply RSG30: from unit No. DB001004267 orange coloured connector | Details |
| 71037408 | threaded terminalFor relay 1+2 (change-over contact). | Details |
| 71037410 | threaded terminalfor relay 2+3 and relay on digital I/O board | Details |
| 71037411 | threaded terminalfor relay 4+5+6 on power supply board | Details |
| 71037363 | 9-pin terminalfor digital input on power supply board | Details |
| 71389871 | RSG35 Panel | Details |
| XPR0007- | Spare parts kit, display, RSG35 XPR0007 | Enquire |
| 51009211 | terminal blockfor analog input | Details |
| XPR0008- | CPU + software RSG35 XPR0008Attention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | Enquire |
| 71187780 | Industrial SD Memory Card 1GB | Details |
| XPR0009- | Software RSG35 XPR0009Attention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | Enquire |
| 71273443 | Tubus Paperless Recorder RSG35/RSG45 | Details |
| 71035184 | lifting screw | Details |
| RXU10- | Data Manager Accessory RXU10 | Enquire |
| DIENST- | ServiceAttention: Please note the instructions for DIENST-F/T in the option text! | Enquire |
Configurator / Comparison
Manuals & Documents 9
All documents for this model9 documents · click to expand
Ecograph T, RSG35 Chinese
BA Ecograph T RSG35 Chinese
FDM Field Data Manager Software MS20, MS21 English
FDM Field Data Manager Software MS20, MS21 English
BA Ecograph T RSG35 English
BA Ecograph T RSG35 English
Ecograph T, RSG35 Operating Instructions English
Ecograph T RSG35 Chinese
TI Ecograph T RSG35 English
Product Videos
Case Studies
Municipal Wastewater Treatment · data manager — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.
What We Did
We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.
Food & Beverage · data manager — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.
Delivery Approach
Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · data manager — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.
Implementation
The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.
Power & Energy · data manager — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.
Solution
The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.
Related Products
Endress+HauserEngyCal RH33
Endress+HauserAdvanced Graphic Data Manager RSG45
Endress+HauserEnergy Manager RMC621
Endress+HauserSteam- and Heat computer RMS621
Endress+HauserBatch Controller RA33
Endress+HauserField Data Manager Software MS21
Endress+HauserRockwell asset health monitoring solution
Endress+Hauser