The flow and energy manager RMC621 calculates standard volume as well as mass and energy flows of natural and technical gases, fluids and steam from flow, pressure, temperature and density. Depending on the medium calculation of the energy values occurs according to international standards (IAPWSIF97, SGERG88), real gas equations (SRK) or specific tables. For differential pressure measurements coefficients for flow compensation are calculated over the complete operating range of the flow sensor.
Compare

Energy & Application Manager

Measuring Principle
Measuring principle Flow and energy manager
Function Gas, liquids, steam and water bilancing for industrial energy management
Calculations mass/heat quantity
heat quantity difference
for gases: standard volume, heating value, mass
Number of applications 3
Data storage no
Calculation standards IAPWS IF97
AGA8 / SGERG88
Nx/9
API 2540
customer spezific tables
ISO 5167
Communication 1 x RS232
2 x RS485
PROFIBUS DP
M-Bus
Modbus RTU
Power supply Not defined
Loop power supply 90...250V AC 50/60 Hz
20...28V AC 50/60 Hz
20...36V DC
Protection class IP20
Input 2...8x PFM
2...8x I
2...8x Impulse (aktiv)
2...6x RTD
2...8x Impulse (passiv)
Output 3...9x transmitter power supply
Dimensions (WxHxD) 135 x 108 x 114 mm (5.32" x 4.25" x 4.49")
Operation Soft keys RS232 and operation software ReadWin 2000
Display LC-Dot-Matrix 160 x 80 Punkte
Software functions International calculation standards for gas, liquids, steam and water
Certificates ATEX Ex ia

Product Overview

The RMC621 flow and energy manager uses flow, pressure, temperature and density to calculate the standard volume, mass and energy flow of natural gas and special gases. Depending on the medium, energy values are calculated and expressed using international standards (IAPWSIF97, SGERG88), the real gas equation of state (SRK) or special tables. When measuring differential pressure, the flow compensation factor is calculated over the entire operating range of the flow sensor.

  • Advantages

  • Suitable for gases, liquids, steam and water

  • Up to 3 measurement applications can be calculated simultaneously for different fluids

  • Process calculations such as density, enthalpy and compressibility are based on equations and built-in material data tables for high precision

  • Calculation standards: IAPWS-IF 97, SGERG88, AGA8, real gas equation of state (SRK, RK), ISO 5167, tables

  • Usable with all common flow measuring systems (vortex, turbine, MID, orifice plate, differential pressure, etc.)

  • Density signal input compensation

  • Logging function records date and time of error messages and parameter changes

  • Areas of application

  • Energy calculation management

  • Chemical industry

  • Heating and air conditioning

  • Pharmaceutical industry

  • Food and beverages

  • Plant and instrument manufacturing

  • Oil and petrochemicals

Spare Parts & Accessories 28

28 spare parts · click to collapse
Order codeDescription
RMC621X-Spare part RMC621X-Enquire
RMC621X-Spare part RMC621X-Enquire
71402350Panel mounting accessoryfor RMA42x/RMx621/RTA421/RN221N/TMT12xDetails
51004063terminal blockAnalogue terminal 1 (PFM/pulse/analogue/loop power)Details
51004064terminal blockAnalogue terminal 2 (PFM/pulse/analogue/loop power)Details
51004067terminal blockTerminal temperat.1(Pt100/Pt500/Pt1000)Details
51004068terminal blockTerminal temperat.2(Pt100/Pt500/Pt1000)Details
51004907terminal block(Pt100/Pt500/Pt1000)Details
51004908terminal block(Pt100/Pt500/Pt1000)Details
51004909terminal blockPFM, pulse, loop powerDetails
51004910terminal blockPFM, pulse, loop powerDetails
51004911terminal blockTerminal RMx/FML621 dig./open collectoDetails
51004912terminal blockTerminal plug-in RMx/FML621 relayDetails
51005953terminal blockPFM, impulse, loop powerDetails
51005954terminal blockTerminal plug-in 4pol.SMSTB2,5 82/81/10/Details
51005955terminal blockTerminal plug-in Ex4pol.SMSTB2,5 1/5/6/2Details
51005956terminal blockTerminal plug-in Ex4pol.SMSTB2,5 3/7/8/4Details
51005957terminal blockTerminal plug-in 4pol.SMSTB2,5 82/81/10/Details
51005958terminal block(Pt100/Pt500/Pt1000)Details
51005959terminal blockPFM, impulse, loop powerDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

10 models · click to collapse
All documents for this model
12 documents · click to expand
BA

RMx621/FML621 Chinese

Rev. 1320 20 pages
Preview
BA

RMx621/FML621 Chinese

Rev. 0120 32 pages
Preview
BA

Operating instructions Flow and energy manager RMC 621 English

Rev. 1517 104 pages
Preview
BA

RMx621 / FML621 English

Rev. 1320 20 pages
Preview
BA

M-Bus for RMx621 English

Rev. 1108 12 pages
Preview
BA

RMx621/FML621 Profibus module English

Rev. 1107 16 pages
Preview
BA

Operating instructions Flow and energy manager RMC 621 English

Rev. 0909 101 pages
Preview
BA

Appendix to operating instructions RMx621 English

Rev. 0809 12 pages
Preview
BA

RMx621/FML621 Profibus module English

Rev. 0809 16 pages
Preview
BA

M-Bus for RMx621 English

Rev. 0807 12 pages
Preview
BA

RMx621 Operating Instructions English

Rev. 0317 12 pages
Preview
BA

M-Bus for RMx621 English

Rev. 0211 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · data manager — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · data manager — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · data manager — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · data manager — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.