Technical Data
CompareData Manager & Data Logger
| Measuring Principle | Data manager |
| Measuring principle | Data Logger |
| Function | Secure data recording and signal analysis visualization integrated web server for device set-up HART(R) transparency, RSG45 as a HART modem E-Mail notification (encrypted mails) 100 ms scan rate, high speed storage cycle 100 ms modular design for simple expansion data readout and processing via Field Data Manager Software OPC server for indication of instantaneous values (optional) |
| Input | 20 analog (max) (U, I, TC, RTD, frequency, pulse) 20 HART (max) (HART, 4…20mA) 14 digital (max) (control, event and counting inputs) |
| Output | 12 relays (max) 2 analog (max) (I, pulse) 1 transmitter power supply |
| Interface | RS232/485 Ethernet USB Modbus RTU/TCP Slave Modbus RTU/TCP Master Profibus DP PROFINET Device EtherNet/IP Adapter |
| Storage/Recording | internal memory SD card USB flash drive |
| Display | TFT 7" colour graphic display TFT 7" colour graphic display with touch panel |
| Housing | panel mounting with zink diecast bezel panel mounting with stainless steel bezel desktop housing field housing |
| Power supply | 100...230 V AC +/-10% 24V (-10%; +15%) AC/DC |
| Certificates | EAC UL (US und CA) ATEX II2G Ex px IIC Gb ATEX II2D Ex pD IIIC Db UL listed PROFINET certified |
| Software package | Batch software Waste water software Tele-alarm software Energy software (water + steam) Waste water + storm overflow + Tele Alarm Tele-alarm software + energy software (water + steam) |
Energy & Application Manager
| Measuring Principle | Energy manager |
| Measuring principle | Energymanager |
| Function | Mass flow and energy calculation for Water and Steam. |
| Calculations | Mass/heat quantity heat quantity difference |
| Number of applications | 8 |
| Calculation standards | IAPWS-97 |
| Communication | RS232/485 Ethernet USB Modbus RTU/TCP Slave Modbus RTU/TCP Master Profibus DP PROFINET Device EtherNet/IP Adapter |
| Power supply | Not defined |
| Loop power supply | 24 V DC +/-15% |
| Protection class | IP65 (front-panel) |
| Input | 0...20 universal HART 6…14 digital |
| Output | 2 analog |
| Dimensions (WxHxD) | 195,2 x 149,2 x 227,1 mm (7,69" x 5,87" x 8,94") |
| Operation | Navigator on-site, web server and via FieldCare/DeviceCare |
| Display | 7“ TFT |
| Software functions | Internal calculation for mass flow and energy |
| Certificates | ATEX Ex px, Ex pD UL listed PROFINET certified EAC Non-hazardous area + KC marking |
The advanced data manager is a flexible and powerful process value processing system. With intuitive operation, the Memograph M quickly and easily meets the requirements of various applications. Process measured values are clearly displayed on the screen and securely recorded; limit values are monitored and analyzed. Via common communication protocols, both measured and calculated values can be easily communicated to higher-level systems and allow interconnection of the individual plant modules. A DIN rail version without display is also available.
Benefits
High data security: tamper-proof data storage unit and personalized access rights with electronic signature (FDA 21 CFR 11)
HART input card: direct connection of HART sensors providing accurate process values for calculation and recording
HART gateway: with the Memograph M, HART sensors in the field can be accessed directly via FieldCare without interrupting the measuring loop, saving time
Stainless steel front panel with touch keys: fault-free operation under demanding conditions, e.g. hygienic or hazardous-area applications
DIN rail version: all-in-one, small size, suitable for cabinet installation or remote field applications
System capability: supports common fieldbuses (Modbus, Profibus DP, PROFINET, industrial Ethernet (EtherNet/IP)) for fast integration into various systems
Built-in web server: remote access and viewing of device operation with low maintenance costs
WebDAV: direct transfer of files stored on the SD card to a PC via HTTP without additional software
Application areas
Solutions for a wide range of tasks, for example:
Process measurement technology
Power plants and energy supply
Steam boiler monitoring / energy efficiency calculation
Food and pharmaceutical industries
Plant and equipment engineering and construction; milk pasteurizers
Environmental and climate measurement technology; spillage control
Quality assurance and production
Batch analysis; telegram function
iTHERM TrustSens calibration monitoring
Test chambers and laboratory applications
Spare Parts & Accessories 24
24 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| 51009211 | terminal blockfor analog input | Details |
| 71037410 | threaded terminalfor relay 2+3 and relay on digital I/O board | Details |
| 71037350 | 4-pin terminalMemograph M for analog output (on digital I/O board) RIA45 for analog input non Ex (terminal x1,x2,x3,x4 + x5,x6,x7,x8) | Details |
| 71037351 | Terminal block, 10-pinfor digital input on digital I/O board | Details |
| 71296182 | terminal block | Details |
| 71123475 | terminal blockfor power supply RSG30: from unit No. DB001004267 orange coloured connector | Details |
| 71037408 | threaded terminalFor relay 1+2 (change-over contact). | Details |
| 71037411 | threaded terminalfor relay 4+5+6 on power supply board | Details |
| 71037363 | 9-pin terminalfor digital input on power supply board | Details |
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| XPR0012- | RSG45 SoftwareAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. | Enquire |
| 71187780 | Industrial SD Memory Card 1GB | Details |
| XPR0011- | Spare part RSG45 XPR0011 | Enquire |
| RXU10- | Data Manager Accessory RXU10 | Enquire |
| 71035184 | lifting screw | Details |
Configurator / Comparison
Source: public information from the Endress+Hauser website
Measuring principle video
Click to playManuals & Documents 12
All documents for this model12 documents · click to expand
Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
BA Memograph M RSG45 Chinese
Memograph M,RSG45 Chinese
iTHERM TrustSens自标定监测 Chinese
FDM Field Data Manager Software MS20, MS21 English
Product Videos
Case Studies
Municipal Wastewater Treatment · data manager — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.
What We Did
We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.
Food & Beverage · data manager — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.
Delivery Approach
Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · data manager — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.
Implementation
The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.
Power & Energy · data manager — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.
Solution
The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.
Related Products
Endress+HauserEngyCal RH33
Endress+HauserEnergy Manager RMC621
Endress+HauserSteam- and Heat computer RMS621
Endress+HauserEcograph T RSG35
Endress+HauserBatch Controller RA33
Endress+HauserField Data Manager Software MS21
Endress+HauserRockwell asset health monitoring solution
Endress+Hauser