SWA50 FieldPort

SWA50 FieldPort
FieldPort SWA50
The FieldPort SWA50 converts the HART signal of the connected HART field device to a reliable and encrypted Bluetooth® or WirelessHART signal. The Endress+Hauser SmartBlue app or the Endress+Hauser Field Xpert is used to configure the FieldPort SWA50 and to visualize the measured values and status of the connected HART field device. HART field devices can be connected to the Netilion Cloud via the FieldPort SWA50 and a FieldEdge device.
Compare

Wireless components

Measuring Principle WirelessHART
Function Intelligent WirelessHART and/or Bluetooth® interface module for easy and fast connection to HART devices
Certification Non-hazardous area, ATEX, IEC Ex
Input One point-to-point with HART device
Output WirelessHART and/or Bluetooth® communication interface,
Operating frequency: 2.4 GHz (ISM band),
Transmission range under reference conditions:
WirelessHART communication - up to 200 m (656 ft),
Bluetooth communication - up to 40 m (131 ft)
Auxiliary power supply / Loop power supply Loop-powered 4 to 20 mA
Dimensions (wxhxd) W x H x D: 146 mm x 42 mm x 42 mm
(dimensions in mm 25.4 = 1 inch)
Software Internal software for reading data from HART field devices and communicating over WirelessHART and/or Bluetooth®
Operation Integral via DIP-switches,
Cell Phone configuration via SmartBlue App and Bluetooth®,
Field Xpert configuration via Bluetooth®  or HART-modem,
PC configuration via FieldCare and HART-modem,
PC configuration via FieldCare and WirelessHART Gateway
Operating Voltage 24 V DC (min. 4 V DC, max. 30 V DC): min. 3.6 mA loop current required for start-up
Voltage drop if internal HART communication resistor is deactivated:
3.2 V in operation, < 3.8 V at start-up
Voltage drop if internal HART communication resistor is activated (270 Ohm):
< 4.2 V at 3.6 mA loop current, < 9.3 V at 22.5 mA loop current

FieldPort SWA50 connects HART field devices and reliably converts the HART signal into an encrypted Bluetooth® or WirelessHART signal. Use the Endress+Hauser SmartBlue app or Endress+Hauser Field Xpert to configure FieldPort SWA50 and view the measured values and the status of the connected HART field devices. HART field devices can be connected to the Netilion cloud ecosystem via FieldPort SWA50 and FieldEdge.

Benefits
Connect FieldPort SWA50 to reliably transmit process measured values via encrypted Bluetooth® or WirelessHART communication

  • Easily upgrade all two-wire or four-wire HART field devices

  • All HART field devices can be easily connected to the Netilion cloud ecosystem

  • The adapter is loop-powered and does not interfere with the process signal

  • Easily query diagnostic information of the connected HART field devices via the wireless connection

Application
FieldPort can easily upgrade all two-wire or four-wire HART field devices and can be installed in hazardous and non-hazardous areas. FieldPort SWA50 is equipped with a stainless steel housing, is robust and durable, and can be used in demanding operating conditions.
 

 

Spare Parts & Accessories 1

1 spare parts · click to collapse
Order codeDescription
71520242Mounting kit SWA50Mounting kit for tube or wall mounting- Usage: FieldPort SWA50.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source: Endress+Hauser public website information

All documents for this model
6 documents · click to expand
BA

BA FieldPort SWA50 Chinese

Rev. 0624 72 pages
Preview
BA

BA FieldPort SWA50 Chinese

Rev. 0524 84 pages
Preview
BA

BA FieldPort SWA50 English

Rev. 0624 76 pages
Preview
BA

BA FieldPort SWA50 English

Rev. 0524 92 pages
Preview
TI

TI FieldPort SWA50 Chinese

Rev. 0824 24 pages
Preview
TI

TI FieldPort SWA50 English

Rev. 0824 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gateways and modems — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Gateways and modems and the core task is converting field data into remote transmission channels.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Gateways and modems cannot be specified generically — it calls for configured by protocol, tag count and carrier network conditions.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by protocol, tag count and carrier network conditions, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is remote sites can report back, making unattended operation possible.

Food & Beverage

Food & Beverage · Gateways and modems — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted Gateways and modems properly configured on the existing plant, with the aim of converting field data into remote transmission channels.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Gateways and modems configuration has to involve configured by protocol, tag count and carrier network conditions.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant configured by protocol, tag count and carrier network conditions, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is remote sites can report back, making unattended operation possible, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gateways and modems — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was converting field data into remote transmission channels.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by protocol, tag count and carrier network conditions.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around configured by protocol, tag count and carrier network conditions, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — remote sites can report back, making unattended operation possible, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · Gateways and modems — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Gateways and modems, focusing on converting field data into remote transmission channels.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Gateways and modems specification must therefore cover configured by protocol, tag count and carrier network conditions.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by protocol, tag count and carrier network conditions, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — remote sites can report back, making unattended operation possible, with confidence in this measuring point improving markedly.