SWA50 HART适配器

SWA50 HART适配器

FieldPort SWA50

The FieldPort SWA50 converts the HART signal of the connected HART field device to a reliable and encrypted Bluetooth® or WirelessHART signal. The Endress+Hauser SmartBlue app or the Endress+Hauser Field Xpert is used to configure the FieldPort SWA50 and to visualize the measured values and status of the connected HART field device. HART field devices can be connected to the Netilion Cloud via the FieldPort SWA50 and a FieldEdge device.
Compare

Wireless components

Measuring Principle WirelessHART
Function Intelligent WirelessHART and/or Bluetooth® interface module for easy and fast connection to HART devices
Certification Non-hazardous area, ATEX, IEC Ex
Input One point-to-point with HART device
Output WirelessHART and/or Bluetooth® communication interface,
Operating frequency: 2.4 GHz (ISM band),
Transmission range under reference conditions:
WirelessHART communication - up to 200 m (656 ft),
Bluetooth communication - up to 40 m (131 ft)
Auxiliary power supply / Loop power supply Loop-powered 4 to 20 mA
Dimensions (wxhxd) W x H x D: 146 mm x 42 mm x 42 mm
(dimensions in mm 25.4 = 1 inch)
Software Internal software for reading data from HART field devices and communicating over WirelessHART and/or Bluetooth®
Operation Integral via DIP-switches,
Cell Phone configuration via SmartBlue App and Bluetooth®,
Field Xpert configuration via Bluetooth®  or HART-modem,
PC configuration via FieldCare and HART-modem,
PC configuration via FieldCare and WirelessHART Gateway
Operating Voltage 24 V DC (min. 4 V DC, max. 30 V DC): min. 3.6 mA loop current required for start-up
Voltage drop if internal HART communication resistor is deactivated:
3.2 V in operation, < 3.8 V at start-up
Voltage drop if internal HART communication resistor is activated (270 Ohm):
< 4.2 V at 3.6 mA loop current, < 9.3 V at 22.5 mA loop current

FieldPort SWA50 connects HART field devices and reliably converts the HART signal into an encrypted Bluetooth® or WirelessHART signal. Use the Endress+Hauser SmartBlue app or Endress+Hauser Field Xpert to configure FieldPort SWA50 and view the measured values and the status of the connected HART field devices. HART field devices can be connected to the Netilion cloud ecosystem via FieldPort SWA50 and FieldEdge.

Benefits
Connect FieldPort SWA50 to reliably transmit process measured values via encrypted Bluetooth® or WirelessHART communication

Easily upgrade all two-wire or four-wire HART field devices

All HART field devices can be easily connected to the Netilion cloud ecosystem

The adapter is loop-powered and does not interfere with the process signal

Easily query diagnostic information of the connected HART field devices via the wireless connection

Application
FieldPort can easily upgrade all two-wire or four-wire HART field devices and can be installed in hazardous and non-hazardous areas. FieldPort SWA50 is equipped with a stainless steel housing, is robust and durable, and can be used in demanding operating conditions.
 

 

E+H product model configuration tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below, up to three products

 

   

Technical documentation

   

Technical specifications

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Source: Endress+Hauser public website information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Gateways and Modems Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Gateways and Modems Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Gateways and Modems Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Gateways and Modems Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.