Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TM151 iTHERM ModuLine

TM151 iTHERM ModuLine
iTHERM ModuLine TM151
Modular industrial RTD / TC thermometer, complete with barstock thermowell or to be used with onsite thermowell.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
with neck or iTHERM QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with iTHERM StrongSens
Thermowell / protection tube barstock (drilled) or to be used with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 16 mm (0,63")
18 mm (0,71")
19 mm (0,75")
19,5 mm (0,77")
20 mm (0,79")
22,2 mm (0,87")
24 mm (0,95")
25 mm (0,98")
25,4 mm (1,0")
26 mm (1,02")
27 mm (1,06")
30 mm (1,18")
33,4 mm (1,31")
Max. immersion length on request up to 1.500,0 mm (59,06'')
Material protection tube/ thermowell 316 (1.4401)
316L (1.4404)
316/316L (1.4401/1.4404)
316Ti (1.4571)
347 (1.4550)
310 (1.4841)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
10CrMo9-10 (1.7380)
13CrMo4-5 (1.7335)
16Mo3 (1.5415)
A105 (1.0460)
C22.8 (P250GH) (1.0460)
P355NH (1.0565)
Duplex S32205 (1.4462)
Titanium Gr2 (3.7035)
Process connection Male thread:
G1"
NPT1/2", NPT3/4", NPT 1"
M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
Female thread:
M24x1.5
NPT1/2"
Flange:
DN25 PN16, PN40, PN50, PN100 B1
DN40 PN40 B1
DN50 PN40, PN63 B1
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1" 600 RF
ASME 1" 900/1500 RF
ASME 1 1/2" 150 RF
ASME 1 1/2" 300 RF
ASME 1 1/2" 600 RF
ASME 1 1/2" 900/1500 RF
ASME 1 1/2" 2500 RF
ASME 2" 150 RF
ASME 2" 300 RF
ASME 2" 600 RF
ASME 2" 900/1500 RF
ASME 2" 2500 RF
to weld-in:
Diameter 18 mm (0,71")
Diameter 24 mm (0,94")
Diameter 26 mm (1,02")
Diameter 26,7 mm (NPS 3/4")
Diameter 33,4 mm (NPS 1")
Tip shape straight
tapered
stepped
Surface roughness Ra 0,76 μm (30 μin.)
1,6 μm (63,0 μin.)
Operating temperature range PT100 TF iTHERM StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 TF iTHERM QuickSens:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static) depending on the configuration up to 500 bar
Accuracy Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Response time depending on configuration
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ec, Ex tc
ATEX IECEx Ex ia
NEPSI Ex ia
NEPSI Ex d
NEPSI Ex tb
NEPSI Ex DB,
KC Ex ia
INMETRO Ex ia
IND Ex
EAC Ex
Certification SIL, MID, DNV/GL

iTHERM ModuLine TM151
Industrial modular thermometer
Metric RTD/TC thermometer with bar stock thermowell for a wide range of industrial applications
Advantages
Second process seal with fault indication, providing valuable device health information

iTHERM QuickSens: fastest response time of 1.5 s for optimum process control

iTHERM StrongSens: unmatched vibration resistance (> 60g), ensuring plant safety

iTHERM QuickNeck: easy recalibration without tools, saving cost and time

Bluetooth® connection (optional)

International certifications: explosion protection in accordance with ATEX, IECEx, CSA C/US and CCC standards
Field of application
Modular industrial RTD or TC thermometer with bar stock thermowell or for use with an existing thermowell. Optionally with Endress+Hauser temperature transmitter for increased accuracy and reliability - easy customization by selecting outputs and communication protocols. Optional Bluetooth® connection. The thermometer features the latest innovations such as the iTHERM QuickNeck and temperature sensor technologies such as iTHERM QuickSens and iTHERM StrongSens.

Wide range of applications

Measuring range: –200 to +1,100 °C (–328 to +2,012 °F)

Pressure range up to 500 bar (7,252 psi)

Vibration-resistant sensor element, up to 60g

Easy maintenance (sensor replacement without shutting down), simple and safe recalibration of the measuring point

Spare Parts & Accessories 61

61 spare parts · click to collapse
Order codeDescription
TA30A-Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
TA30D-Junction box TA30DRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Details
71600564O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 piecesDetails
TA30P-Junction Box TA30PRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).Enquire
TA30R-Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight.Enquire
71182606Seal5x O-ring 57x2.5 5x O-ring 64.3x1.8 blauDetails
XPT0004-Spare Parts Kit Cover TA30Rcover of connecting headEnquire
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
XPT0002-plug connectorEnquire
RK01-System component RK01Enquire
51004653cable glandfor 2 sensorsDetails
510046541/2" NPT cable glandfor 2 sensorsDetails
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
51004915M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VADetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
51516983Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).Details
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
SFP20-FieldPort SFP20 USB/IO-Link modemIO-Link USB interface FieldPort SFP20 for commissioning and maintaining of IO- Link measuring devicesEnquire
71460208Dedicated M12 connector for FieldPort SFP20Cable to connect the FieldPort SFP20 with an IO-Link deviceDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

BA iTHERM ModuLine工业温度计 Chinese

Rev. 0325 24 pages
Preview
BA

BA iTHERM ModuLine thermometer English

Rev. 0325 28 pages
Preview
TI

TI iTHERM ModuLine TM151 Chinese

Rev. 0425 76 pages
Preview
TI

TI iTHERM ModuLine TM151 English

Rev. 0425 80 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.