Technical Data
CompareThermometer
| Measuring Principle | Resistance Temperature Detector |
| Characteristic / Application | metric style modular temperature assembly universal range of application suitable for hazardous areas suitable for high process pressures with neck or iTHERM QuickNeck incl. thermowell / protection tube (metal) or to be installed into thermowell can be used with iTHERM StrongSens |
| Thermowell / protection tube | barstock (drilled) or to be used with thermowell |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 16 mm (0,63") 18 mm (0,71") 19 mm (0,75") 19,5 mm (0,77") 20 mm (0,79") 22,2 mm (0,87") 24 mm (0,95") 25 mm (0,98") 25,4 mm (1,0") 26 mm (1,02") 27 mm (1,06") 30 mm (1,18") 33,4 mm (1,31") |
| Max. immersion length on request | up to 1.500,0 mm (59,06'') |
| Material protection tube/ thermowell | 316 (1.4401) 316L (1.4404) 316/316L (1.4401/1.4404) 316Ti (1.4571) 347 (1.4550) 310 (1.4841) Alloy 600 (2.4816) Alloy C276 (2.4819) 10CrMo9-10 (1.7380) 13CrMo4-5 (1.7335) 16Mo3 (1.5415) A105 (1.0460) C22.8 (P250GH) (1.0460) P355NH (1.0565) Duplex S32205 (1.4462) Titanium Gr2 (3.7035) |
| Process connection | Male thread: G1" NPT1/2", NPT3/4", NPT 1" M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2 Female thread: M24x1.5 NPT1/2" Flange: DN25 PN16, PN40, PN50, PN100 B1 DN40 PN40 B1 DN50 PN40, PN63 B1 ASME 1" 150 RF ASME 1" 300 RF ASME 1" 600 RF ASME 1" 900/1500 RF ASME 1 1/2" 150 RF ASME 1 1/2" 300 RF ASME 1 1/2" 600 RF ASME 1 1/2" 900/1500 RF ASME 1 1/2" 2500 RF ASME 2" 150 RF ASME 2" 300 RF ASME 2" 600 RF ASME 2" 900/1500 RF ASME 2" 2500 RF to weld-in: Diameter 18 mm (0,71") Diameter 24 mm (0,94") Diameter 26 mm (1,02") Diameter 26,7 mm (NPS 3/4") Diameter 33,4 mm (NPS 1") |
| Tip shape | straight tapered stepped |
| Surface roughness Ra | 0,76 μm (30 μin.) 1,6 μm (63,0 μin.) |
| Operating temperature range | PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F) |
| Max. process pressure (static) | depending on the configuration up to 500 bar |
| Accuracy | Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2 |
| Response time | depending on configuration |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX Ex ec, Ex tc ATEX IECEx Ex ia NEPSI Ex ia NEPSI Ex d NEPSI Ex tb NEPSI Ex DB, KC Ex ia INMETRO Ex ia IND Ex EAC Ex |
| Certification | SIL, MID, DNV/GL |
iTHERM ModuLine TM151
Industrial modular thermometer
Metric RTD/TC thermometer with bar stock thermowell for a wide range of industrial applications
Advantages
Second process seal with fault indication, providing valuable device health information
iTHERM QuickSens: fastest response time of 1.5 s for optimum process control
iTHERM StrongSens: unmatched vibration resistance (> 60g), ensuring plant safety
iTHERM QuickNeck: easy recalibration without tools, saving cost and time
Bluetooth® connection (optional)
International certifications: explosion protection in accordance with ATEX, IECEx, CSA C/US and CCC standards
Field of application
Modular industrial RTD or TC thermometer with bar stock thermowell or for use with an existing thermowell. Optionally with Endress+Hauser temperature transmitter for increased accuracy and reliability - easy customization by selecting outputs and communication protocols. Optional Bluetooth® connection. The thermometer features the latest innovations such as the iTHERM QuickNeck and temperature sensor technologies such as iTHERM QuickSens and iTHERM StrongSens.
Wide range of applications
Measuring range: –200 to +1,100 °C (–328 to +2,012 °F)
Pressure range up to 500 bar (7,252 psi)
Vibration-resistant sensor element, up to 60g
Easy maintenance (sensor replacement without shutting down), simple and safe recalibration of the measuring point
Spare Parts & Accessories 61
61 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| TA30A- | Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | Enquire |
| TA30D- | Junction box TA30DRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | Enquire |
| 71182602 | Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75 | Details |
| 71600564 | O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 pieces | Details |
| TA30P- | Junction Box TA30PRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing). | Enquire |
| TA30R- | Terminal box TA30RRetainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temperature: -50...+85/+130oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact design and low weight. | Enquire |
| 71182606 | Seal5x O-ring 57x2.5 5x O-ring 64.3x1.8 blau | Details |
| XPT0004- | Spare Parts Kit Cover TA30Rcover of connecting head | Enquire |
| TA30H- | Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing). | Enquire |
| XPT0002- | plug connector | Enquire |
| RK01- | System component RK01 | Enquire |
| 51004653 | cable glandfor 2 sensors | Details |
| 51004654 | 1/2" NPT cable glandfor 2 sensors | Details |
| 51006845 | cable glandCable gland NPT 1/2, D4-8.5, IP68 | Details |
| 51004915 | M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VA | Details |
| TXU10- | Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线 | Enquire |
| 51516983 | Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate). | Details |
| FXA195- | Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508. | Enquire |
| SFP20- | FieldPort SFP20 USB/IO-Link modemIO-Link USB interface FieldPort SFP20 for commissioning and maintaining of IO- Link measuring devices | Enquire |
| 71460208 | Dedicated M12 connector for FieldPort SFP20Cable to connect the FieldPort SFP20 with an IO-Link device | Details |
Configurator / Comparison
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to playManuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · thermistor — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.
Food & Beverage · thermistor — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · thermistor — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.
Power & Energy · thermistor — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Implementation
The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.
Related Products
Endress+HauseriTHERM ModuLine TM101
Endress+HauseriTHERM ModuLine TM131
Endress+HauserRTD Thermometer TR10
Endress+HauseriTHERM ModuLine TM111
Endress+HauseriTHERM CompactLine TM311
Endress+HauserCompact Thermometer TMR31
Endress+HauserRTD Thermometer TR24
Endress+Hauser