Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TM372 Self-calibrating temperature sensor

TM372 Self-calibrating temperature sensor
Self-calibrating temperature sensor
The award-winning smart temperature probe with integrated HART® transmitter and Heartbeat Technology features the world’s first RTD sensor unit capable of fully automated in-situ self-calibration. It effectively eliminates the risk of undetected non-conformities, reduces production downtime and increases product safety and process efficiency in applications of the food & beverage and life sciences industries. The device is fully compliant to FDA 21 CFR Part 11 regulations and GMP rules.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application self-calibrating
imperial style
compact temperature probe
hygienic design
hygienic process connection
Thermowell / protection tube without
incl. thermowell
incl. Tee-/elbow thermowell
Insert / probe pipe version, isolated wires, not flexible
Outer diameter protection tube / Insert 1/4'' (6,35 mm)
3/8'' (9,53 mm)
1/2" (12,7 mm)
Max. immersion length on request up to 28'' (711 mm)
others on request
Material protection tube/ thermowell 316L
Process connection Weld-in adapter
Tri-clamp
Clamp-connections according to ISO2852
G3/4" Liquiphant
G1" Liquiphant
Varivent
T- and elbow thermowell
Tip shape straight
reduced
Surface roughness Ra 30 μin (0,76 μm)
15 μin (0,38 μm )
15 μin (0,38 μm ) electropolished
Operating temperature range PT 100:
-40 °C …160 °C (-40 °F …320 °F),
optional up to 190 °C (374 °F)
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Response time t50 = 2,5 s
t90 =9,5s
Integration head transmitter no (4…20mA Signal)
Ex - approvals ATEX IECEx Ex ia
CSA C/US IS

The award-winning intelligent temperature probe integrates a HART® transmitter and Heartbeat Technology and is equipped with the world's first fully automatic in-situ self-calibrating RTD sensor unit. It is suitable for food & beverage and life sciences industry applications and effectively eliminates the risk of undetected non-compliance, shortens downtime and increases product safety and process efficiency. The device fully complies with FDA 21 CFR Part 11 and GMP standards.

Advantages

  • The self-calibration function and Heartbeat Technology reduce operating risk and costs

  • Fully automatic, fully traceable online self-calibration means the production process does not need to be interrupted

  • Fully automatic archiving of records, storage of 350 calibration points.

  • Calibration certificates can be printed for use as audit documentation.

  • Automatic 4-20 mA loop testing saves time and increases process safety. Learn how iTHERM TrustSens performs fully automatic loop testing in five simple steps. The video shows the device setup and how your process benefits.

  • Avoids non-compliance or undetectable faults

  • International certificates and approvals: ASME BPE, FDA, 3-A, 1935/2004, 2023/2006, 10/2011, CE CRN, CSA general certification

  • Highest measuring accuracy at the measuring point through sensor-transmitter matching

Application

  • Specifically designed for hygienic and aseptic applications in the food & beverage and life sciences industries

  • Measuring range: –40...+160 °C (–40...+320 °F)

  • Maximum pressure: 50 bar (725 psi)

  • Protection rating: IP67/68 or IP69K

  • Communication: 4...20 mA HART® analog output

Spare Parts & Accessories 24

24 spare parts · click to collapse
Order codeDescription
TT412-iTHERM ModuLine TT412Thermowell with hygienic design. Imperial version for applications in the food/beverages and pharmaceutical industries.Enquire
52018765weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ", FMI51, FTI51 "GQJ" Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
52028295weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ" w/o flange Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
52021717O-ringfor weld-in adapter G3/4 D=50 316L Liquiphant T FTL20HDetails
52001052weld socketFlush mount process connection FTL50/FTL50H "GQ2" Material: 316L Seal: Silicone O-ringDetails
52011897weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL41, FTL43, FTL50, FTL50H, FTL51B, FTL63, FTL80, QMW43, TMR35.Details
52014473O-ringfor weld-in adapter G3/4 Liquiphant M "GQ2"Details
71093129weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL20H, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51B, FTL51H, FTL63, FTL80, FTL81, FTL260, PMP135, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43.Details
52014472O-ringfor weld-in adapter G1 (52001051) Liquiphant M "GW2" Liquiphant T "7", Liquicap M "GWJ", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for weld-in andapter G1, 316L 3.1 (52011896) Liquiphant M "GW2", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for sliding sleeve Soliphant TDetails
52001051Process connection | Weld-in G1, d=60, 316L齐平安装式过程连接 FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" 材质: 316L 密封: 硅橡胶 O-ringDetails
52011896Welding socket, G1, d=60, 3.1 material certificateFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
52001221weld socketFlush mount process connection FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2" Liquiphant is adjustable Material: 316L Seal: Silicone O-ringDetails
52011898weld socketFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2" Liquiphant is adjustable Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
52014424Sealing gasketfor weld-in adapter G1, adjustable, 316L (52001221) Liquiphant M "GW2" for weld-in adapter G1, adjustable, 316L (52011898) Liquiphant M "GW2" for weld-in adapter G1, adjustable Liquiphant FTL330H/FTL330L, Liquiphant T FTL20H "UPJDetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
71392158TXU10 upgrade adapter kit for TM371Details
51516983Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).Details
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
FXA42-Fieldgate FXA42Compact gateway for data capture of field devices, without antenna. Embedded web server, alarm / event handling. Application: remote monitoring, inventroy data monitoring, web enabled field interface. Field device interfaces 4-20mA, Modbus RTU, digital inputs/outputs. :: Meets NAMUR NE43 requirements. :: Data transition into SupplyCare.Enquire
71387767Cable connector M12 IP69k 5mDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
11 documents · click to expand
BA

BA iTHERM TrustSens TM371 Chinese

Rev. 0826 104 pages
Preview
BA

iTHERM TrustSens自标定监测 Chinese

Rev. 0222 24 pages
Preview
BA

BA iTHERM TrustSens TM372 Chinese

Rev. 0222 92 pages
Preview
BA

BA iTHERM TrustSens TM371 English

Rev. 0826 110 pages
Preview
BA

BA iTHERM TrustSens TM372 English

Rev. 0426 100 pages
Preview
BA

BA iTHERM TrustSens Calibration Monitoring English

Rev. 0325 20 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI iTHERM TrustSens TM371 Chinese

Rev. 0925 44 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI iTHERM TrustSens TM371 English

Rev. 1026 48 pages
Preview
TI

TI iTHERM TrustSens TM372 English

Rev. 0426 36 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.