Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TMS01 多点温度计

 TMS01 多点温度计

多点温度计

By complying with the highest safety standards, iTHERM TMS01 can be customized for various applications. Bendable into a 3D layout, it provides a complete temperature profile just by using one nozzle. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available either with TC or RTD technology or with our iTHERM StrongSens.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
easy-to-use
suitable for hazardous areas
flanged process connection
light chemical processes
3D sensors distributions
modular design
replaceable sensors during shutdown
Thermowell / protection tube without (for direct contact sensors type)
with (for replaceable sensors)
with (for increased mechanical protection)
Multi-thermowells, each one dedicated to a sensor
Insert / probe mineral insulated (MI), flexible
mineral insulated (MI), flexible, with its own thermowell
Outer diameter protection tube / Insert 6,0 mm (0,24'')
8,0 mm (0,31")
10,29 mm (1/8")
Max. immersion length on request up to 30.000,00 mm (1181'')
Material protection tube/ thermowell 1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4550 (347)
Alloy 600 (2.4816)
Process connection flange:
2" ASME/ANSI B16.5 150
...600
3" ASME/ANSI B16.5 150
..600
4" ASME/ANSI B16.5 150
...600
6" ASME/ANSI B16.5 150
...600
8" ASME/ANSI B16.5 150
...600
DN80 EN/DIN 1092.1 PN10
...PN100
DN100 EN/DIN 1092.1 PN10
...PN100
DN125 EN/DIN 1092.1 PN10
...PN100
DN150 EN/DIN 1092.1 PN10
...PN100
DN200 EN/DIN 1092.1 PN10
...PN100
Tip shape straight
Operating temperature range Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 920 °C
(max. 1.688 °F)
Type N:
max. 1.150 °C
(max. 2.102 °F)
Type T:
max. 370 °C
(max. 698 °F)
Max. process pressure (static) at 20 °C: 100 bar (1450 psi)
Accuracy class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
Response time depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX
UL
FM
CSA
NEPSI
Certification SIL (transmitter only)
NEPSI

iTHERM MultiSens Flex TMS01
Multipoint thermometer
Direct contact TC/RTD temperature profile solution with 3D bendable sensors for oil, gas and petrochemical applications
Advantages
Easy-to-use device with modular and flexible design that can be installed directly for direct contact measurement or via a sensor-specific protection tube. The device can also be installed in an already positioned thermowell

Unlimited layout of the 3D sensor distribution for any desired process monitoring configuration

Modular product design, easy to install, integrate into the process and maintain, highly customizable

High insert process compatibility, complying with IEC 60584, ASTM E230 and IEC 60751 standards

Onboard electronic thermal protection for maximum product durability

Complies with different types of protection for use in hazardous locations, facilitating process integration
Field of application
The iTHERM TMS01 complies with the highest safety standards and can be customized for various applications. It can be bent into a 3D layout and provides a complete temperature profile using just one nozzle. The device can be configured with or without a thermowell for optimum response time, mechanical strength or sensor replaceability. It can use TC or RTD technology, as well as our iTHERM StrongSens.

Petrochemical industry

Oil and gas industry

Heavy chemical processes

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Thermocouple Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Thermocouple Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Thermocouple Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Thermocouple Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.