TMS01 Multipoint thermometer

TMS01 Multipoint thermometer
Multipoint thermometer
By complying with the highest safety standards, iTHERM TMS01 can be customized for various applications. Bendable into a 3D layout, it provides a complete temperature profile just by using one nozzle. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available either with TC or RTD technology or with our iTHERM StrongSens.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
easy-to-use
suitable for hazardous areas
flanged process connection
light chemical processes
3D sensors distributions
modular design
replaceable sensors during shutdown
Thermowell / protection tube without (for direct contact sensors type)
with (for replaceable sensors)
with (for increased mechanical protection)
Multi-thermowells, each one dedicated to a sensor
Insert / probe mineral insulated (MI), flexible
mineral insulated (MI), flexible, with its own thermowell
Outer diameter protection tube / Insert 6,0 mm (0,24'')
8,0 mm (0,31")
10,29 mm (1/8")
Max. immersion length on request up to 30.000,00 mm (1181'')
Material protection tube/ thermowell 1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4550 (347)
Alloy 600 (2.4816)
Process connection flange:
2" ASME/ANSI B16.5 150
...600
3" ASME/ANSI B16.5 150
..600
4" ASME/ANSI B16.5 150
...600
6" ASME/ANSI B16.5 150
...600
8" ASME/ANSI B16.5 150
...600
DN80 EN/DIN 1092.1 PN10
...PN100
DN100 EN/DIN 1092.1 PN10
...PN100
DN125 EN/DIN 1092.1 PN10
...PN100
DN150 EN/DIN 1092.1 PN10
...PN100
DN200 EN/DIN 1092.1 PN10
...PN100
Tip shape straight
Operating temperature range Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 920 °C
(max. 1.688 °F)
Type N:
max. 1.150 °C
(max. 2.102 °F)
Type T:
max. 370 °C
(max. 698 °F)
Max. process pressure (static) at 20 °C: 100 bar (1450 psi)
Accuracy class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
Response time depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX
UL
FM
CSA
NEPSI
Certification SIL (transmitter only)
NEPSI

iTHERM MultiSens Flex TMS01
Multipoint thermometer
Direct contact TC/RTD temperature profile solution with 3D bendable sensors for oil, gas and petrochemical applications
Advantages
Easy-to-use device with modular and flexible design that can be installed directly for direct contact measurement or via a sensor-specific protection tube. The device can also be installed in an already positioned thermowell

Unlimited layout of the 3D sensor distribution for any desired process monitoring configuration

Modular product design, easy to install, integrate into the process and maintain, highly customizable

High insert process compatibility, complying with IEC 60584, ASTM E230 and IEC 60751 standards

Onboard electronic thermal protection for maximum product durability

Complies with different types of protection for use in hazardous locations, facilitating process integration
Field of application
The iTHERM TMS01 complies with the highest safety standards and can be customized for various applications. It can be bent into a 3D layout and provides a complete temperature profile using just one nozzle. The device can be configured with or without a thermowell for optimum response time, mechanical strength or sensor replaceability. It can use TC or RTD technology, as well as our iTHERM StrongSens.

Petrochemical industry

Oil and gas industry

Heavy chemical processes

Spare Parts & Accessories 11

11 spare parts · click to collapse
Order codeDescription
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT86-Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive.Enquire
TMT162-Field temperature transmitter TMT162Temperature transmitter. Application: RTD, TC, Ohm, mV. HART, PROFIBUS PA or FOUNDATION Fieldbus separately available. Galvanic isolation 2 kV (sensor input/output). NEMA 4x, IP67. Dual compartment. GL (German Lloyd)Marine (only HART). UL listed.Enquire
TMT142B-iTEMP Temperature Transmitter HART TMT142B2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC, presetting failure current low.Enquire
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71044062equipment package2x screws, 1x sealing CDI-connectorDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
6 documents · click to expand
BA

BA iTHERM TMS01多点柔性温度计 Chinese

Rev. 0625 40 pages
Preview
BA

BA iTHERM MultiSens Flex TMS01 English

Rev. 0625 44 pages
Preview
TI

TI iTHERM MultiSens Flex TMS01 多点温度计 Chinese

Rev. 0625 28 pages
Preview
TI

TI iTHERM ProfileSens TS901 Chinese

Rev. 0223 16 pages
Preview
TI

TI iTHERM MultiSens Flex TMS01 Multipoint thermometer English

Rev. 0625 28 pages
Preview
TI

TI iTHERM ProfileSens TS901 English

Rev. 0223 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.