Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TMT128 iTEMP TMT128, Transmitter DIN rail TC

TMT128 iTEMP TMT128, Transmitter DIN rail TC
iTEMP TMT128, Transmitter DIN rail TC
The transmitter is designed for the transformation of a TC sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications. Installation is realized on DIN rail according to IEC 60715 (housing width: 22.5 mm).
Compare

Temperature transmitters

Measuring Principle Rail transmitter
Input 1 x TC
Output 1 x analog 4...20 mA
Auxiliary power supply 12...35 V DC (standard-version)
12...30 V DC (Ex-version)
Installation DIN-rail
Accuracy (Type K) <= 0,5 K
(Type K) <=0,9 °F
Galvanic isolation yes
Certification UL rec. Comp
marine approval
GOST Metrology
ATEX Ex ia, Ex nA
CSA IS, NI
CSA General Purpose
FM IS, NI
FM+CSA IS, NI

The transmitter is designed to convert thermocouple (TC) sensor signals within a fixed measuring range. The standard output signal used in process measurement is a 4...20 mA signal. This means fast, simple and economical temperature measurement with reliable, accurate measured values suitable for all industries. Mounted on a DIN rail conforming to IEC 60715 (housing width: 22.5 mm).

Benefits

  • High-accuracy measurement over the entire ambient temperature range

  • Fault signal in the event of sensor open-circuit or short-circuit, presettable in accordance with NAMUR NE43

  • Meets EMC requirements in accordance with NAMUR NE21, CE approval

  • Explosion protection certificates: ATEX Ex ia, FM IS, CSA IS

  • UL-certified component, conforming to UL 3111-1

  • GL marine approval

  • Galvanic isolation

Application

  • Fixed-range temperature transmitter for converting TC input signals into a 4 …20 mA analog output signal

  • Input: thermocouple (TC) 

  • Suitable for DIN rail mounting

Spare Parts & Accessories 5

5 spare parts · click to collapse
Order codeDescription
51006248terminal blockTerminal plug-in 4pole SMSTB2,5 printedDetails
51006249terminal blockTerminal plug-in 4pole SMSTB2,5 printedDetails
51006250terminal blockTerminal plug-in 2pole RM5 printed -/+Details
51006251terminal blockTermin plug-in 2pole RM5 printed -/+Details
71402350Panel mounting accessoryfor RMA42x/RMx621/RTA421/RN221N/TMT12xDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

All documents for this model
4 documents · click to expand
BA

BA157R TMT 127/128 Operating Instructions Version 09.03 English

26 pages
Preview
BA

BA157R TMT 127/128 Operating Instructions Version 09.03 English

21 pages
Preview
TI

Technical information iTEMP ® TC DIN rail TMT128 English

Rev. 1008 8 pages
Preview
TI

Technical information iTEMP ® TC DIN rail TMT128 English

7 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.