Technical Data
CompareTemperature transmitters
| Measuring Principle | |
| Input | 1 x RTD (Pt100) |
| Output | 1 x analog 4...20 mA |
| Auxiliary power supply | 8...35 V DC (standard-version) 8...30 V DC (Ex-version) |
| Installation | Terminal head form B |
| Accuracy | (Pt100, -50...200 °C) <= 0,2 K (Pt100, -58...392 °F) <= 0,4 °F |
| Galvanic isolation | yes |
| Certification | UL Ex IS UL Ex NI GOST Ex i GL ship approval GOST Metrology FM IS,NI,Class I,Div.1+2,Group ABCD CSA IS,NI,Class I,Div.1+2,Group ABCD ATEX II1G EEx ia IIC T4/T5/T6 ATEX II3G Ex nA IIC Gc ATEX II3D Ex tc IIIC Dc ATEX II1G Ex ia IIC T6 Ga, II3D ATEX II3G Ex nA IIC Gc, II3D FM+CSA IS,NI,Class I,Div.1+2,Group ABCD CSA General Purpose EAC Ex ia IIC T6 Ga GL (German Lloyd) |
Product Overview
Designed for signal transmission of resistance thermometers (RTD) Pt100 within a fixed measuring range. A 4 ... 20 mA standard current output signal is used for process measurement. Suitable for use in all industries, providing fast, convenient and economical temperature measurement with reliable and accurate measured values.
-
Benefits
-
High-accuracy measurement over the entire ambient temperature range.
-
Fault signal in the event of sensor open-circuit or short-circuit, preset in accordance with NAMUR NE 43.
-
Electromagnetic compatibility (EMC) in accordance with NAMUR NE 21, CE approval
-
Explosion protection: ATEX Ex ia and Zone 22 dust ignition protection in accordance with EN 50281-1, FM IS and CSA IS
-
Component certified in accordance with UL 3111-1
-
Marine approval
-
Galvanic isolation
Spare Parts & Accessories 3
3 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 51001112 | temperature transmitter spare parts(4 screws, 6 springs, 10 spring rings) | Details |
| 71528231 | DIN rail mounting accessoryClip according to IEC 60715 for temperature head transmitters. Packing unit: 2 pieces | Details |
| TAF10- | Remote junction box TAF10Application: E+H Head transmitter Housing: Alu IP66, 100x100x60mm. | Enquire |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment · Temperature transmitter — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.
Food & Beverage · Temperature transmitter — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Temperature transmitter — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.
Implementation
The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.
Power & Energy · Temperature transmitter — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.
Related Products
Endress+HauseriTEMP TMT72, Transmitter HART
Endress+HauseriTEMP TMT182, Head Transmitter HART
Endress+HauseriTEMP TMT82, Transmitter HART
Endress+HauseriTEMP TMT71, Transmitter 4-20mA
Endress+HauseriTEMP TMT80, Head Transmitter
Endress+HauseriTEMP TMT31, Transmitter 4-20mA
Endress+HauseriTEMP TMT142, Field Transmitter HART
Endress+Hauser