Order Code:TMT72-AAA1AABA1+B2C1H1
Name:iTEMP TMT72, Transmitter HART
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Communication; Output Signal; Operation | A | HART; 4-20mA; HART configuration |
| 030 | Housing Shape | 1 | Form B head transmitter, DIN EN 50446 |
| 040 | Electrical Connection | A | Screw terminals |
| 050 | Field Housing | AB | W/o, mounting set DIN terminal head |
| 480 | Device Model | A1 | 1 |
| 510 | Universal Input | B2 | RTD/Ohm 3-wire |
| 520 | Sensor Type | C1 | Pt100, IEC60751 (a=0.00385), -200...+850oC, min. span 10K |
| 570 | Service | H1 | Failure current, presetting low |
Configuration Explained
This is a TMT72 modular temperature transmitter, HART protocol, for non-hazardous areas, 2-wire 4-20mA HART output, online commissioning with a HART handheld terminal, Form B transmitter head with screw terminals, installed in the junction box with a DIN standard transmitter head kit, without field housing, Pt100 three-wire input, covers -200 to +850 °C, minimum span 10 K, factory-set low-limit alarm, timely warning when limits are exceeded, suitable for temperature measurement in water treatment and general process lines.