Order Code:TMT72-NAA1AA4A1
Name:iTEMP TMT72, Transmitter HART
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | NA | NEPSI Ex ia IIC T6 Ga |
| 020 | Communication; Output Signal; Operation | A | HART; 4-20mA; HART configuration |
| 030 | Housing Shape | 1 | Form B head transmitter, DIN EN 50446 |
| 040 | Electrical Connection | A | Screw terminals |
| 050 | Field Housing | A4 | TA30A, Alu, 2x NPT1/2, glass display window (w/o display unit), universal housing with hinged cover |
| 480 | Device Model | A1 | 1 |
Configuration Explained
This is a TMT72 modular temperature transmitter, HART protocol, with NEPSI intrinsically safe approval, can be installed in hazardous areas, 2-wire 4-20mA HART output, online commissioning with a HART handheld terminal, screw terminal wiring, TA30A cast aluminium housing with hinge, 2 x ½ NPT cable entries, glass window, for intrinsically safe loops with safety barrier, rugged housing, vibration and impact resistant, suitable for transmitter head installation and routine inspection on site in chemical plants.
Related Products
Endress+HauseriTEMP TMT72, Transmitter HART
Endress+HauseriTEMP TMT182, Head Transmitter HART
Endress+HauseriTEMP TMT82, Transmitter HART
Endress+HauseriTEMP TMT71, Transmitter 4-20mA
Endress+HauseriTEMP TMT80, Head Transmitter
Endress+HauseriTEMP TMT31, Transmitter 4-20mA
Endress+HauseriTEMP TMT122,Transmitter DINrail HART
Endress+Hauser