Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TMT82-JCD3/1E0

TMT82-JCD3/1E0
Product family: iTEMP TMT82, Transmitter HART
iTEMP TMT82, Transmitter HARTIn Stock (4)
Endress+Hauser TMT82-JCD3/1E0
iTEMP TMT82, Transmitter HART;Approval NEPSI Ex ia IIC T6 Ga;Communication/Output Signal HART; 1x 4-20mA;Electrical Connection Screw terminals, housing form B, DIN EN 50446;Field Housing W/o, mounting set DIN terminal head;Configuration Universal Input Ch1: TC, Ch2: inactive;Sensor Type Input 1 Type K, IEC 584, -270...+1372oC, min. span 50K;Sensor Type Input 2 Inactive;Input/Interconnection PV=CH1; CH2 inactive

Order Code:TMT82-JCD3/1E0

Corresponding ext. order code:TMT82-NAA2AD1TKAAA1

Name:iTEMP TMT82, Transmitter HART

Configuration

CodeNameOrderSpecification
010ApprovalNANEPSI Ex ia IIC T6 Ga
020Communication; Output SignalAHART; 1x 4-20mA
030Electrical Connection2Screw terminals, housing form B, DIN EN 50446
040Field HousingAW/o, mounting set DIN terminal head
050Configuration Universal InputD1Ch1: TC, Ch2: inactive
060Sensor Type Input 1TKType K, IEC 584, -270...+1372oC, min. span 50K
070Sensor Type Input 2AAInactive
080Input; InterconnectionA1PV=CH1; CH2 inactive

Configuration Explained

This is a TMT82 temperature transmitter, HART communication, NEPSI intrinsically safe version, can be installed in hazardous areas, 1 x 4-20mA HART output, screw terminal wiring, Form B transmitter head with DIN standard mounting kit, installed in the thermocouple junction box, without field housing, thermocouple signal input, complies with IEC 584, millivolt signal converted locally into current, strong interference immunity, suitable for temperature measurement in intrinsically safe loops of kilns and heating equipment.