Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TMT84 temperature transmitter

TMT84 temperature transmitter
iTEMP TMT84, Transmitter PA
Configurable Models 5 models
Convert sensor signals into standard digital output signals suitable for all industries. Equipped with PROFIBUS ® PA communication protocol
Compare

Temperature transmitters

Measuring Principle Head transmitter
Input 2 x RTD, TC, Ohm, mV
Output PROFIBUS PA
Auxiliary power supply 9...32 V DC (PROFIBUS PA)
9...17,5 V DC (FISCO/FNICO)
Communication PROFIBUS PA
Installation Terminal head form B
Accuracy (Pt100) <= 0,1 K
(Pt100) <= 0,18 °F
Galvanic isolation yes
Certification ATEX Ex ic, Ex tb, Ex ia, Ex nA,Ex tc, Ex d
ATEX IECEx Ex ia
IECEx Ex ia, Ex tb, Ex d
CSA C/US General Purpose
CSA IS, NI, XP, DIP
FM IS, NI, XP, DIP
FM+CSA IS, NI
INMETRO Ex ia [ia Ga], Ex d, Ex tb
NEPSI Ex ia, Ex d, Ex tb
EAC Ex ia, Ex d
UKCA Ex tb, Ex tc, Ex ia, Ex nA, Ex db
IND Ex
PESO Ex
Non-hazardous area + KC marking (Head, Field)

This configurable transmitter offers outstanding reliability, accuracy and long-term stability and can be used in critical processes in all industries. It not only transmits digitally converted signals from resistance thermometers (RTD) and thermocouples (TC), but can also transmit resistance and voltage signals using the PROFIBUS® PA communication protocol. Sensor monitoring increases the effectiveness of the measuring point. Diagnostic information complies with NAMUR NE 107. Measuring accuracy is optimized by sensor-transmitter matching.

 

Advantages

Simple and standardized communication using the PROFIBUS® PA Profile 3.02 protocol.

Meets electromagnetic compatibility (EMC) requirements in accordance with NAMUR NE 21; the temperature transmitter with digital signal processing also complies with the NAMUR-recommended NE 89 standard.

Explosion-proof design based on FISCO/FNICO conformity requirements, in accordance with IEC 600079-27.

International approvals such as FM IS, NI, CSA IS, NI as well as ATEX Ex ia, Ex nA (Ex NL) ensure safe operation in hazardous locations.

Spare Parts & Accessories 16

16 spare parts · click to collapse
Order codeDescription
TA30A-Terminal box TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
TA30D-Junction box TA30DRetainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602Seal5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Details
TA30H-Junction box TA30HRetainer for terminal block or head transmitter + optional display. Design: explosion proof Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50#150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).Enquire
71600564O-ring 74x3 75° VMQ silicone rubberPacking unit: 5 piecesDetails
51004948front cover latch pinScrew, washer, spring washerDetails
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71044062equipment package2x screws, 1x sealing CDI-connectorDetails
TID10-Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84.Enquire
71086650TID10 service cableExtension cable for the CDI-interface for remote operation of the TID10 display for service and maintenance work. Length: 40cm.Details
71528231DIN rail mounting accessoryClip according to IEC 60715 for temperature head transmitters. Packing unit: 2 piecesDetails
RK01-System component RK01Enquire
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
71274384pipe mounting bracketDetails
71274372Wall mounting bracketDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
5 models · click to collapse
Diagnostic codes(20 条)→ Diagnostic codes(20 条)→
All documents for this model
9 documents · click to expand
BA

BA iTEMP TMT84 Chinese

Rev. 0726 96 pages
Preview
BA

TID10 Operating Instructions English

Rev. 1313 9 pages
Preview
BA

BA iTEMP TMT84 English

Rev. 0726 108 pages
Preview
BA

Operating Instructions TID10 English

Rev. 0408 5 pages
Preview
BA

Operating Instructions TID10 English

Rev. 0408 9 pages
Preview
TI

TI iTEMP TMT84 Chinese

Rev. 0926 24 pages
Preview
TI

技术资料 iTEMP® TMT84 Chinese

Rev. 0412 20 pages
Preview
TI

TI iTEMP TMT84 English

Rev. 0926 24 pages
Preview
TI

Technical Information iTEMP® TMT84 English

Rev. 0412 18 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.