Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | metric style modular temperature assembly for heavy duty applications suitable for hazardous areas with neck incl. thermowell / protection tube (metal) usable with insert StrongSens |
| Thermowell / protection tube | welded protection tube |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 9,0 mm (0,35'') 11,0 mm (0,43'') 12,0 mm (0,47'') |
| Max. immersion length on request | up to 10.000,00 mm (393,70'') |
| Material protection tube/ thermowell | 1.4404 (316L) 1.4571 (316Ti) AlloyC276 (2.4819) |
| Optional coating | Not defined |
| Process connection | male thread: G1/2" G3/4" G1" NPT1/2" NPT3/4" M20x1,5 compression fitting: G1/2" flange: ASME 1" 150 RF (B16.5) ASME 1" 300 RF (B16.5) DN25 PN40 B1 (EN1092) DN40 PN40 B1(EN1092) DN50 PN40 B1 (EN1092) |
| Tip shape | straight reduced tapered |
| Surface roughness Ra | Not defined |
| Operating temperature range | PT100 TF StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) |
| Max. process pressure (static) | at 20 °C: 100 bar (1.450 psi) |
| Accuracy | class A acc. to IEC 60751 class AA acc. to IEC 60751 |
| Response time | depending on configuration t50 = 8 s t90 = 21 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6 ATEX II 2 GD Ex d IIC ATEX II 3 G Ex nA IIC T6, II3D ATEX II 1/2 GD Ex d IIC IECEx Ex d Ga/Gb IIC T6/T5/T4,Ex tD A20 IECEx Ex ia IIC T6 Ga/Gb IECEx Ex d IIC T6/T5/T4 IECEx Ex d IIC T6/T5/T4, Ex tD A21 EAC Ex ia IIC T6 Ga + DIP EAC Ex d IIC T6 Gb + DIP NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450 NEPSI Ex d IIC T6 NEPSI Ex nA IIC T6 Explosion proof |
| Certification | Gost Metrology SIL (transmitter only) |
This thermometer is rugged and suitable for harsh conditions and high-safety measurement applications in the chemical, oil, gas and energy industries. The robust thermowell and special materials withstand harsh working environments, corrosive substances and high pressure. The optional transmitter is compatible with various common communication protocols and is ready to use; compared with directly wired sensors, it improves measuring accuracy and reliability, and the device setup is flexible.
Benefits:
Explosion protection types: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)
-
High insert compatibility, design in accordance with DIN 43772
-
Extension neck prevents transmitter overheating
-
Short taper/conical tip for faster response time
-
Modular design with a standard terminal head per DIN EN 50446 and customer-specified insertion depth for high flexibility
-
Spare Parts & Accessories 31
31 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71312729 | Heat transfer oil HSC 340, 100 g | Details |
| 71249291 | Heat Transfer Oil, FDA Certified, 30 g | Details |
| 71044061 | equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector | Details |
| TPR100- | RTD insert TPR100Mineral insulated cable (MgO) Replaceable insert acc.EN60751. max. measuring range: -200...600 oC (depending on configuration) | Enquire |
| TPR300- | RTD element TPR300Replaceable insert (MgO) to use with TR6x line. max. measuring range: -200...600 oC (depending on configuration) | Enquire |
| TW10- | *** Thermowell TW10screw in, Protection tube acc. DIN 43772 /2G+3G, welded version. | Enquire |
| TW11- | *** Protection Tube TW11to screw in Pipe-version, welded, DIN 43772 / 2G + 3G | Enquire |
| TW12- | *** Thermowell TW12screw in, Protection tube acc. DIN 43772 /2+3, without neck, welded version. | Enquire |
| TW13- | *** Thermowell TW13with flange connection. Protection tube acc. DIN 43772 /2F+3F welded version. | Enquire |
| TA50- | Mounting parts, compression fitting TA50Screw in. | Enquire |
| TA21H- | Terminal head TA21HProduct Phased Out. Retainer for terminal block or head transmitter. Design: explosion proof. Cover: screwed. Ambient temp.: -40...100 oC (housing). Protection: IP66/68 (housing). | Enquire |
| TMT85- | Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | Enquire |
| TMT84- | Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | Enquire |
| TMT82- | Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | Enquire |
| TMT85- | Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | Enquire |
| TMT84- | Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | Enquire |
| TMT82- | Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | Enquire |
| TID10- | Temperature transmitter display TID10to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84. | Enquire |
| TXU10- | Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线 | Enquire |
| READWIN- | Readwin 2000 Commissioning Package READWINReadwin 2000 Operation + Read. software | Enquire |
Configurator / Comparison
Source: public information from the Endress+Hauser website
Measuring principle video
Click to playManuals & Documents 3
All documents for this modelCase Studies
Municipal Wastewater Treatment · thermistor — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.
Food & Beverage · thermistor — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · thermistor — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.
Power & Energy · thermistor — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.
Implementation
The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.
Related Products
Endress+HauseriTHERM ModuLine TM101
Endress+HauseriTHERM ModuLine TM131
Endress+HauserRTD Thermometer TR10
Endress+HauseriTHERM ModuLine TM111
Endress+HauseriTHERM CompactLine TM311
Endress+HauserCompact Thermometer TMR31
Endress+HauserRTD Thermometer TR24
Endress+Hauser