Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

2978100Discontinued

2978100
1720E Turbidimeter with SC200 Controller, 1 ChannelDiscontinued
HACH 2978100
Compliant with EPA Method 180.1, the 1720E Low Range Turbidimeter is a trusted, continuous-reading nephelometric turbidimeter designed for low-range turbidity monitoring. A built-in bubble removal sys

产品概述

The low range turbidimeter

Compliant with EPA Method 180.1, the 1720E Low Range Turbidimeter is a trusted, continuous-reading nephelometric turbidimeter designed for low-range turbidity monitoring. A built-in bubble removal system allows the 1720E to be sensitive to fine changes in low level turbidity. When connected to a Hach SC controller, the instrument can store up to 6 months of measurement logs, verification data, and other instrument information for complete data reporting. Verification is made easy with the optional ICE-PIC module that allows for verification of the turbidimeter in less than one minute.

The 1720E is passing the torch to the TU5300 sc. The last day to order the 1720E is July 27, 2018. See the recommended products section of this page or visit HachTU5.com to learn more.

主要特点

  • Accuracy:Continuously flowing sample flows through the patented* bubble removal system, which vents entrained air from the sample stream and eliminates the most significant interference in low level turbidity measurement. The 1720E Turbidimeter is not affected by variations in flow and pressure.
  • Simplicity:A simplified two-module design includes the sensor and the controller interface. The controller accepts two turbidity sensors and adding a second 1720E sensor makes a system with two complete turbidimeters. Connections are simple plug & play.
  • Data Collection and Display:The 1720E Turbidimeter uses the sc200 Controller to receive data from up to two sensors. A built-in data logger collects turbidity measurement at user selectable intervals (1-15 minutes), along with calibration and verification points, alarm history, and instrument setup changes for 6 months. Communications using Modbus® RS485, MODBUS® RS232, HART, or Profibus DP.
  • USEPA Reporting:Meets and exceeds USEPA Method 180.1 for measuring turbidity for drinking water compliance. One controller accepts up to two plug and play sensors giving you two complete turbidimeters. Sensitive to fine changes in low level turbidity with a built-in bubble removal system.
  • Experience:The 1720E Turbidimeter reflects 45 years of Hach leadership in turbidity measurement science. Hach has the largest turbidimeter installation base in the world. And, Hach offers a two-year warranty on the 1720E.
  • Fast Calibration and Verification:Calibration and verification can be performed without loss of sample flow using the ICE-PIC™ Calibration/Verification Module. One-point calibration with prepared Stablcal™ Stabilized Formazin Solution eliminates the errors of user-prepared formazin suspension dilution. Features of the ICE-PIC Module include: • Less than one minute to calibrate or verify the performance of each sensor • Factory calibrated and provided with a certificate of accuracy • Cost effective, one-time investment. No consumables are needed • Small, lightweight design can be used for spot verification in the facility • Available in 20 and 1.0 NTU

技术参数

参数名称说明
Accuracy±2% of reading or ±0.02 NTU (whichever is greater) from 0 - 40 NTU
Accuracy 2±5% of reading from 40 - 100 NTU (Defined according to ISO 15839.)
AlarmWhen connected to sc controller: three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac
CertificationsCE certified by Hach Company to EN61326 (industrial levels)
CertificationsListed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1
CommunicationWhen connected to sc controller: MODBUS RS232/RS485, PROFIBUS, HART
Compliance CertificationsStandard Methods 2130B, USEPA 180.1, Hach Method 8195
ControllerSingle Digital
Dimensions (H x W x D)254 mm x 305 mm x 406 mm
MountingTurbidimeter body and head assembly: wall and floor stand sc controller: wall, pole, panel, and floor stand
Number of Channels1
Operating Humidity5 - 95 % non-condensing
Operating Temperature Range0 - 50 °C (Single Sensor System)
Operating Temperature Range0 - 40 °C (Double Sensor System)
OutputsUp to five selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc Controller
Power Requirements (Hz)50 - 60 Hz
Power Requirements (Voltage)115 - 230 VAC
Range0.001 - 100 Nephelometric Turbidity Units (NTU)
RepeatabilityBetter than ± 1.0 % of reading or ±0.002 NTU, whichever is greater (Defined according to ISO 15839.)
Response TimeInitial response in 1 minute, 15 seconds for a full-scale step change
Sample Flow Rate200 - 750 mL/minute (3.1 - 11.9 gal/hour)
Sample Input1/4 inch NPT female, 1/4 inch compression fitting (provided)
Sample Output1/2 inch NPT female, 1/2 inch hose barb (provided)
Sample Temperature0 - 70°C (32 - 122°F)
Ship Wt. (lbs)1720E Turbidimeter: 5.9 kg (13 lbs.)
Signal Average TimeUser selectable from 0, 6, 30, 60, 90 seconds
Storage Conditions-20 to 60 °C (-4 to 140 °F)
Warranty12 months
What's included?Hach sc200 Controller, Mounting Hardware, sc controller Basic User Manual, 1720E, 1720E User Manual, and 1000 mL 20 NTU Stablcal ®. (The controller power cord is ordered separately.)

资料下载

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Controllers and Sensors — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.

What We Did

We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Controllers and Sensors — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.

Delivery Approach

Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Controllers and Sensors — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.

Implementation

The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Controllers and Sensors — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.

Solution

The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.