Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

NITRATAX sc online nitrate analyzer

NITRATAX sc online nitrate analyzer
sc online nitrate analyzer
HACH NITRATAX
Nitratax sc nitrate online analyzer uses a highly accurate UV absorption method and can be equipped with sensors of different path lengths for nitrate nitrogen measurement. When the Nitratax sc nitrate nitrogen analyzer probe is working, the water sample flows through the gap, and the light emitted by the light source in the probe passes through the gap. Part of the light is absorbed by the sample flowing in the gap, while the rest of the light passes through the sample and reaches the detector on the other side of the probe, thereby completing the nitrate nitrogen measurement and calculating the nitrate concentration value.

Typical Applications

The Nitratax sc nitrate online analyzer continuously monitors the dissolved nitrate concentration in water. It is suitable for nitrate nitrogen measurement in drinking water, surface water, industrial process water, wastewater treatment, and other fields, and is especially suitable for monitoring aeration tanks in wastewater treatment and controlling the denitrification process.

Instrument Features

  • The Nitratax sc nitrate online analyzer uses the UV absorption dual-beam measurement method for precise monitoring

  • The Nitratax sc nitrate online analyzer requires no reagents or sample pretreatment, providing fast reaction and analysis

  • The Nitratax sc nitrate online analyzer offers three different sensors as options

  • The sensor features an automatic cleaning function

  • The Nitratax sc nitrate analyzer offers flexible installation, with two installation options available: immersion and flow-through cell

  • Low maintenance and low operating cost

Technical Specifications

  • Sensor Model              NITRATAX plus sc                         NITRATAX eco sc                        NITRATAX clear sc

  • Measuring principle       UV absorption dual-beam measurement method, no chemical reagents required          

  • Measuring optical path       1mm, 2mm, 5mm                                      1mm                                          5mm

  • Measuring range              NO3-N 0.1~100.0mg/L                         1.0~20.0mg/L                         0.5~20.0mg/L

  •                     (1 mm)                                                        (1 mm)                                       (5 mm)

  •                     0.1~50.0mg/L          

  •                     (2 mm)          

  •                     0.1~25.0mg/L          

  •                      (5 mm)          

  • Minimum detection limit NO3-N    0.1 mg/L                                       1.0 mg/L                                    0.5 mg/L

  • Measuring accuracy        ± 3% of reading ± 0.5mg/L                  ± 5% of reading ± 1.0mg/L              ± 5% of reading ± 0.5mg/L

  • Resolution           0.1 mg/L                                                   0.5 mg/L                                   0.1 mg/L

  • Sludge compensation function             Yes                                                         Yes                                               -

  • Measuring interval                   1min                                                5min                                             1min

  • Measurement response time (T100)   1min                                                15min                                           1min

  • Flow-through installation method           Yes                                                       No                                                Yes

  • Material               

  • Stainless steel, double seal        Yes                                                        -                                                 -

  • Stainless steel, single seal         -                                                        Yes                                               Yes

  • Calibration    Standard solution calibration          

  • Maintenance interval                    6 months, or based on on-site water quality and experience          

  • User maintenance time              1 hour / month                                      2 hours / month                                 1 hour / month

  • Operating temperature                     2 ~ 40℃          

  • Sensor pressure resistance                    0.5 bar (sensor installation depth underwater is 2 meters)          

  • Sensor cable length             10 meters, extendable          

  • Dimensions                           33.3 × 7.0 cm                                  32.7 × 7.0 cm                           32.3 × 7.5 cm

Ordering Guide

  • Commonly ordered complete systems

  • The following NITRATAX sc UV nitrate analyzers include an sc200 controller, mounting bracket, and sensors with different optical path lengths

  • 2984000    NITRATAX plus sc instrument, with 2mm optical path sensor

  • 2984100    NITRATAX plus sc instrument, with 2mm optical path flow-through cell sensor

  • 2984200    NITRATAX eco sc instrument, with 1mm optical path sensor

  • 2984300    NITRATAX clear sc instrument, with 5mm optical path sensor

  • 2984400    NITRATAX clear sc instrument, with 5mm optical path flow-through cell sensor

Individual orders

  • Individual NITRATAX sc UV nitrate sensors, with 10m cable, require an sc200 or sc1000 controller

  • LXV417.99.10002    NITRATAX plus sc sensor, 1mm optical path

  • LXV417.99.20002    NITRATAX plus sc sensor, 2mm optical path

  • LXV417.99.50002    NITRATAX plus sc sensor, 5mm optical path

  • LXV420.99.50002    NITRATAX clear sc sensor, 5mm optical path

  • LXV415.99.10002    NITRATAX eco sc sensor, 1mm optical path

  • Optional mounting and other accessories

  • LZX414.00.10000    Sensor mounting hardware

  • LZX869    Flow-through cell for NITRATAX plus sc sensor, 2mm optical path

  • LZX867    Flow-through cell for NITRATAX plus sc sensor, 5mm optical path

  • LZX866    Flow-through cell for NITRATAX clear sc sensor, 5mm optical path

  • Optional extension cable accessories

  • 57960-00    Extension cable, 7.6m

  • 57961-00    Extension cable, 15.2m

  • 57962-00    Extension cable, 30.5m

Source: Public information from the HACH Water Quality website

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Controllers and Sensors — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.

What We Did

We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Controllers and Sensors — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.

Delivery Approach

Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Controllers and Sensors — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.

Implementation

The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Controllers and Sensors — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.

Solution

The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.