Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

2978300Discontinued

2978300
Filtertrak 660 sc Laser Nephelometer w/ SC200 Controller, 1 ChannelDiscontinued
HACH 2978300
Filtertrak Laser Nephelometer offers the best resolution in the market. Detects changes in turbidity as low as 0.0005 NTU. Complies with USEPA approved Hach Method 10133 for regulatory reporting and c

产品概述

Ultra low range turbidity measurement.

Filtertrak Laser Nephelometer offers the best resolution in the market. Detects changes in turbidity as low as 0.0005 NTU. Complies with USEPA approved Hach Method 10133 for regulatory reporting and compliance monitoring. Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers, sensor can be used with Hach's new SC200 or SC1000 Digital Controllers. Includes Manual and Stablcal Turbidity Standards.

The FT660 is passing the torch to the TU5400 sc. The last day to order the FT660 is July 27, 2018. See the recommended products section of this page or visit HachTU5.com to learn more.

主要特点

  • Lowest Limit of Detection in the Market:Using advanced laser optics and signal processing, the instrument detects increased concentrations of submicron-sized particles that are a precursor to larger particles. This allows for early filter deterioration detection that meets or exceeds that of particle counters all with the day-to-day convenience, simplicity, and reliability of a Hach turbidimeter. Operators can detect impending filter breakthrough, delineate filter ripening, and maximize effective filter run time. The Hach Filtertrak 660 sc Laser Nephelometer has the ability to detect a 0.3 mNTU or 0.0003 NTU change in turbidity, providing operators with confidence in their turbidity measurement.
  • Meets All USEPA Filter Monitoring Requirements:The Filtertrak sensor uses U.S. Environmental Protection Agency (USEPA) approved Hach Filtertrak Method #10133, the method specified in the USEPA LT2 draft guidance manual for compliance monitoring of membrane filters. The sensor meets all regulatory requirements for individual filter and combined effluent monitoring.
  • Monitor, Optimize, and Report:USEPA method compliance means that treatment plants with conventional or membrane filtration can monitor and optimize, as well as report, using this single technology.
  • Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers:The Filtertrak sensor can be used with any of Hach's sc Digital Controllers. Each sc controller accepts from two to eight sensors. Multiple controllers can be networked to accommodate many more sensors and parameters, reducing the cost per measuring point. Just plug in any Hach “plug and play digital sensor and it's ready to use without software configuration. “Plug and play connectivity means there's no complicated wiring or set up. The Filtertrak 660 sc Laser Nephelometer controller system now can manage multiple digital sensors.

技术参数

参数名称说明
Accuracy(Defined according to ISO 15839) From ±3% of reading or ±5 mNTU, whichever is greater
AlarmThree set-point alarms Two nephelometric set-point alarms (SOM required)
Cable Length1.8m (5.9 feet)
Calibration MethodStablcal, stabilized formazin
CertificationsCE certified by Hach Company to EN61326 (industrial levels)
CertificationsListed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1
CommunicationMODBUS® RS485/ RS232, PROFIBUS DP, HART available with sc controller
ControllerSingle Digital
Dimensions (H x W x D)406 mm x 305 mm x 254 mm
Display Resolution0.001 mNTU up to 9.9999 mNTU
Fitting TypeSample Inlet: 1/4-inch NPT female, 1/2-inch hose barb (provided); Drain: 1/2-inch NPT female, 1/2-inch hose barb (provided), clear drain tubing is recommended
Flow100 - 750 mL/min
Flow Rate100 - 750 mL / min (1.6 to 11.9 gal/hour)
Light Source660 nm Laser Diode
Lower Limit of Detection (LOD)(Defined according to ISO 15839) Less than 0.3 mNTU
Lowest Expected Reading5 mNTU using deionized, reverse osmosis water, based on statistical averages from three instruments
Measurement FrequencyOne reading per second
Measuring PrincipleNephelometric light scatter at 90 degrees relative to incident monochromatic light beam
MountingWall and floor stand
Number of Channels1
Operating Humidity5 - 99 % non-condensing
Operating Temperature Range0 - 40 °C
Power Requirements (Voltage)100 - 240 VAC
Range(0.0 - 5.0 NTU) 5000 mNTU = 5.000 NTU
Repeatability+
Repeatability(Defined according to ISO 15839) Better than ± 3.6 % of reading at 24 mNTU; as RSD (or as coefficient of variation)
Resolution0.01 mNTU from 10.00 - 99.99 mNTU
Resolution0.1 mNTU from 100.0 - 999.9 mNTU
Resolution1 mNTU from 1000 - 5000 mNTU
Sample Input0.25 " NPT female thread (1/4" compression fitting provided)
Sample Output0.5 " NPT female thread (1/2" hose barb provided) clear drain tubing is recommended
Sample Temperature0 - 50°C (32 - 122°F)
Signal Average TimeUser selectable from 0, 6, 30, 60, 90 seconds; default 90 seconds
Storage Conditions-20 °C to 60 °C
Warranty12 months
Weight4.54 kg
What's included?Hach sc200 Controller, Mounting Hardware, sc200 Basic User Manual, FT660sc, FT660sc User Manual, and 1000 mL 800 mNTU Stablcal. (The controller power cord is ordered separately.)

资料下载

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Controllers and Sensors — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.

What We Did

We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Controllers and Sensors — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.

Delivery Approach

Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Controllers and Sensors — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.

Implementation

The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Controllers and Sensors — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.

Solution

The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.