产品概述
The Flexibility You Need.
The Hach FL1500 is the one stationary flow logger you need. Flexible sensor options deliver versatility for all of your flow applications. Take control of your data with sensors you can trust
主要特点
- Ensure Accurate Data:Connected with Hach’s complete portfolio of reliable flow sensors, the FL1500 gives you absolute confidence in your flow data. Sensor calibration prompts provide step-by-step guidance, reducing the likelihood of errors.
- Simplify Your Toolkit:The FL1500 is the most agile Hach flow logger, working with the largest selection of Hach sensors to accommodate multiple applications. This multi-channel controller can handle up to four independent flow sensors. The FL1500 can be paired with peripheral equipment such as a rain gauge, pH sensor, auto sampler and mechanical totalizer. Collect measurements with ease from the Hach flow sensors you trust.
- Prioritize Productivity:Built with an easy-to-use color screen, the FL1500 makes operations simpler and more productive. Flexible programming options via keypad, PC (FSDATA software), or USB stick makes programming easier than ever. Additionally, remote communication between the logger and a SCADA or PLC allows for seamless data retrieval.
技术参数
| 参数名称 | 说明 |
|---|---|
| Certifications | CE, cETLus, RCM |
| Communication | USB, RS485 (Modbus) |
| Connection Terminals | 2 |
| Data Download/Output | USB drive, FSDATA Desktop via USB connection |
| Data Storage | Maximum 829,440 measurements (180 days storage, 5-minute logging intervals for 16 parameters); data wraps when full |
| Dimensions | 25.4 cm x 29.2 cm x 12.1 cm, (10.0"H x 12.5"W x 5.25"D),|Including mounting bracket and clear cover (not including cord grips) |
| Display | ¼" VGA, Color, self-prompting menu-driven program |
| Environmental Rating | NEMA 4X, IP66 |
| Languages | English, Spanish, Portuguese, French, German, Italian |
| Material | PC/ABS |
| Operating Temperature Range | -20 - 60 °C (-4 - 140 °F) |
| Options | 2 Sensors, Rain, RS485, 1 analog input, 2 analog outputs, Auxiliary (Sampler), IO9004 port |
| Power Cord | Yes |
| Power Options | 100-240V AC, US Power Cord |
| Power Supply | AC: 100 - 240 VAC, 50/60 Hz, 15 W DC: 10 - 30 VDC, 15 W (Backup Battery option: 12 VDC lead acid battery with AC charger) |
| Program Lock | Access code protection prevents tampering |
| Programming | Controller keypad, USB upload, or via PC using FSDATA Desktop software (requires Windows Operating System, Windows 7 or newer) |
| Relays | Two high voltage relays; Form C, SPDT, 20–230 VAC, 2.0 A |
| Sensor Type | Flo-Dar, SVS, Flo-Tote 3 (NOTE: Flo-Tote 3 is not CE compliant), Sub AV with AV9000S, US9001, US9003, BL9000, Digital Differential pH, Rain Gauge |
| Sensors | 2 |
| Storage Conditions | -40 - 70 °C (-40 - 158 °F) |
| Totalizer | Internal, settable and non-resettable, scalable totalizers. |
| Warranty | 12 months |
| Weight | 3.2 kg (7.0 lb) |
| What's included? | FL1500 Basic Flow Logger, mounting brackets, communications cable, AC power cord |
同系列其他配置
| 型号 | |
|---|---|
| LFV001.99.U4NXH | FL1500 Series Flow Controller Advanced, US Power Cord, Basic User Manu |
资料下载
Case Studies
Municipal Wastewater Treatment · Controllers and Sensors — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.
What We Did
We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.
Food & Beverage · Controllers and Sensors — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.
Delivery Approach
Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Controllers and Sensors — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.
Implementation
The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.
Power & Energy · Controllers and Sensors — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.
Solution
The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.
Related Products