Digital controller for up to two compatible instruments. Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller f

产品概述

Ready for Now. Ready for the Future.

Digital controller for up to two compatible instruments. Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller from HachⓇ is designed to integrate easily into your current system while allowing you to upgrade as your capabilities advance, without having to replace inventory. With a wide range of analog and digital connectivity options and the availability of intelligent instrument and data management features, the SC4500 unlocks the future, today. Instrument is BABA eligible.

主要特点

  • Easy Adoption:The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.
  • No Time for Downtime:The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.
  • The Connectivity Options You Need:The Controller is Smart Monitoring enabled and provides local communication to SCADA or a PLC. From analog and advanced digital protocols to Wi-Fi, cellular or LAN, the SC4500 gives you the flexibility to adapt in a rapidly changing world.

技术参数

参数名称说明
Altitude3000 m (9842 ft) maximum
Analog Output Functional ModeLinear, PID
BABAEligible
Communication (optional)Analog: Five 0 - 20 mA or 4 - 20 mA analog outputs on each analog output module Up to two analog Input modules (0 - 20 mA or 4 - 20 mA). Each input module replaces a digital sensor input. Digital: Profibus DPV1 module with S2 redundancy Modbus TCP Modbus RS Profinet IO module Ethernet IP module HART module
Compatible InstrumentsCompatible Sensors and Analysers / Software Version (Release Year) Amtax sc / V2.30 (2018) or higher A-ISE sc / V1.02 or higher AN-ISE sc / V1.08 (2013) or higher N-ISE sc / V1.02 or higher NH6000sc Ammonium Analyser Nitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higher NT3100sc/NT3200sc Phosphax sc / V2.30 (2018) or higher Phosphax sc LR/MR/HR / V1.01 (2018) or higher TSS sc / V41.73 (2013) or higher Solitax sc / V2.20 (2013) or higher TU5300sc, TU5400sc / V1.34 (2017) or higher SS7 sc (in Bypass) / V1.01 (2006) or higher Ultraturb sc / V3.06 (2017) or higher 1720E / V2.10 (2006) or higher Sonatax sc / V1.15 (2016) or higher CL17sc / V2.7 (2019) or higher CL10sc / V1.14 (2013) or higher 9184sc, 9185sc, 9187sc* / V2.03 (2013) or higher Uvas plus sc / V3.01 (2017) or higher LDO 2 sc* / V1.22 (2013) or higher 3798sc* / V2.03 (2013) or higher 3700sc + Inductive Conductive Digital 6120800 / V3.00 (2017) or higher 3422sc + Contacting Conductive Digital 6120700 / V3.00 or higher 3700 analog + Conductivity Module LXZ525.99.D0004 3400 analog + Conductivity Module LXZ525.99.D0004 pHD sc*, pHD-S sc / V3.10 (2016) or higher 1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higher pHD analog + pH/ORP Module LXZ525.99.D0003 RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher RC and PC analog + pH/ORP Module LXZ525.99.D0003 8362sc* / V3.00 (2017) or higher Polymetron pH/ORP analog + Ultrapure pH/ORP Module LXZ525.99.D0007 Polymetron Conductivity analog + Ultrapure Conductivity Module LXZ525.99.D0006 GS1440 and GS2440EX Sensors H₂S FP360 sc / V1 or higher *Hardware Version1 of instrument is not supported
Compatible Network TechnologiesGSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.) CDMA (e.g. Verizon)
Compliance CertificationsCE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco) C1D2 (available for specific models and North-America only)
Conduit Openings½" NPT conduit
DescriptionMicroprocessor-controlled and menu-driven controller that operates the sensor
Dimensions½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
Display3.5-inch TFT color display with capacitive touchpad
Enclosure RatingUL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4X Metal enclosure with a corrosion-resistant finish
Indoor/OutdoorOutdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
Installation CategoryCategory II
Material EnclosuresPolycarbonate, aluminum (powder coated), stainless steel
MeasurementsTwo device digital SC connectors
MountingWall, Pole, or Panel Mounting
Network ConnectivityOptional: LAN: Two Ethernet connectors (10/100 Mbps) Cellular: External 4G Wi-Fi
Operating Temperature Range-20 - 60 °C (-4 - 140 °F) (8 W (AC)/9 W (DC) sensor load) -20 - 45 °C (-4 - 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
OutputsLAN + mA Output
Pollution Degree4
Power Requirements (Voltage)100 - 240 VAC ±10%, 50/60 Hz; 1 A
Power SupplyWith US plug
Protection ClassI, connected to protective earth
RelaysTwo relays (SPDT); Wire gauge: 0.75 - 1.5 mm² (18 - 16 AWG) AC controller Maximum switching voltage: 100 - 240 VAC Maximum switching current: 5 A Resistive/1 A Pilot Duty Maximum switching power: 1200 VA Resistive/360 VA Pilot Duty DC controller Maximum switching voltage: 30 VAC or 42 VDC Maximum switching current: 4 A Resistive/1 A Pilot Duty Maximum switching power: 125 W Resistive/28 W Pilot Duty Optional Four relays (SPDT); Wire gauge 0.08 - 1.5 mm² (28 - 16 AWG) Maximum switching voltage: 30 VDC Maximum switching current: 1 A Resistive Maximum switching power: 30 W Resistive
Sensor Input #1Digital
Sensor Input #2Digital
Software AvailableNon-Claros + Embedded Prognosys
Storage Conditions-20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
USB PortUsed for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
Warranty12 months
Weight1.7 kg (3.7 lb) (controller only, w/o modules)
What's included?SC4500 Controller, Non-Claros + Embedded Prognosys, with US plug; includes mounting hardware

应用领域

Anaerobic Digestion Biogas · Aquaculture · Ballast Water · Biosolids Dewatering · Boiler Water · Clean in Place (CIP) · Cooling Water · Discharge · Filtration · Flow Monitoring · Groundwater · Industrial Wastewater · Influent for Wastewater · Membrane Protection · Municipal Water · Neutralization · Nutrient Monitoring · Petrochemical · Potable Water · Pre-Treatment · Primary Treatment · Product Loss · Production Water · QA/QC Lab · Recreation/Pool · Regulations · Sea Water · Secondary Treatment · Solids Handling · Source Water · Steam Cycle · Storm Water · Surface Water · Tertiary Treatment · Ultrapure Water · Water Conditioning · Water Cycle · Water Reuse · Water Supply Conditioning

资料下载

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Controllers and Sensors — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.

What We Did

We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Controllers and Sensors — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.

Delivery Approach

Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Controllers and Sensors — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.

Implementation

The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Controllers and Sensors — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.

Solution

The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.