The Hach SC1000 Multi-parameter Universal Controller is a state-of-the-art modular transmitter system. The SC1000 consists of a Display Module and at least one Probe Module. Probe Modules for the SC1000 can be networked together to accommodate up to 32 digital sensors or analyzers. The SC1000 Display Module is intuitive, with an easy to use interface and large color touch-screen display that can be used for any number of parameters. One Display Module controls one or more Probe Modules connected by a digital network. The Display Module is fully portable, and can be disconnected and moved anywhere within the network. The Hach SC1000 Display Module is available with GSM/GPRS, Ethernet, and TCP/IP capability.

主要特点

  • More Confidence in Your Instrument’s Performance:Available exclusively on Hach instruments, Prognosys predictive diagnostics uses innovative diagnostic software to read multiple inputs from your instrument and alert you to the instrument's overall performance and upcoming maintenance. An easy-to-read dashboard provides instant indication of measurement reliability and service requirements. Process control has never been easier.
  • Plug and Play Operation:There’s no complicated wiring or set up procedures with the SC1000 controller. Plug any Hach digital sensor into a Probe Module and it’s ready for use. No special ordering or software configuration is needed.
  • Communication Options to Fit Any Application Need:The Hach SC1000 controller features state-of-the art Modbus TCP/IP communications protocol for seamless integration into a network of devices that support TCP/IP sockets. Use a standard Ethernet cable or connect wirelessly using GSM/GPRS to communicate with your SCADA, PLC or other network. Available with analog 4-20mA, Modbus 485, Profibus DP, or HART digital communication options.
  • Expandable and Upgradable:The SC1000 controller can adapt to your needs. Add or change probes without having to change the controller. Plus, with a single Display Module, additional Probe Modules and associated sensors can be added or removed depending on operational needs. Fully upgradable software ensures that this system will not be obsolete. Hach service plans are available.

技术参数

参数名称说明
AlarmLow alarm point, low alarm point deadband, high alarm point, high alarm point deadband, off delay, and on delay
Analog Output Functional ModePID, high/low phasing, setpoint, deadband, overfeed timer, off delay, on delay
CertificationsNorth American Certifications: cTUVus to UL 61010A-1 and CSA C22.2 No. 1010.1 FCC ID QIPMC56 / IC ID 267W-MC56 European Certifications: CE per 73/23/EEC and 89/336/EEC TUV-GS to EN 61010-1 EN 61326 Amd's 1 & 2
CommunicationModbus® (RS485): Advanced communications/networking with PLC or SCADA system directly from analyzer Profibus® DP/V1 (certified) GSM/GPRS Quad-band cellular module (FCC and IC approved, EU and US only) Ethernet service port, RJ45, 10 MB/s
Dimensions (H x W x D)200 mm x 230 mm x 50 mm
DisplayQVGA, 320 x 240 pixels QVGA, 320 x 240 pixels, 256 colors, touch screen
Display Viewing Area111.4 x 83.5 mm
Enclosure RatingIP65
GSM optionWithout GSM Module
InputsUp to 12 analogue 0-20 mA, maximum impedance 500 Ohms per probe module. Additional inputs are available with additional probe modules.
MaterialEnclosure: Polycarbonate
Material EnclosuresPolycarbonate
MountingSurface, panel, and pipe (horizontal and vertical) with optional sun shield
Operating Temperature Range-20 - 55 °C / 0 - 95% relative humidity, non-condensing
OutputUp to 12 analogue 0/4-20 mA, maximum impedance 500 Ohms per probe module. Additional analogue outputs with additional probe modules. Optional digital communcations via Modbus (RS485) and Profibus DP/V1.
OutputsUp to 12 analog 0/4-20 mA, maximum impedance 500 Ohms per probe module. Additional analog outputs with additional probe modules. Optional digital communcations via Modbus® (RS485) and Profibus® DP/V1.
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)120 - 230 VAC
RelaysUp to four SPDT, user-configurable contacts rated 100 to 230 VAC, 5 Amp resistive maximum per probe module. Additional relays are available with additional probe modules.
Sample Flow Rate400 - 600 mL/min
Sample Inlet Connection1/2" OD Tube Connection
Storage Conditions-20 to 70 °C less than 95% Relative Humidity
Warranty12 months
Weightapprox. 1.2 kg (depending on configuration)
What's included?Display module with communication (as appropriate), basic user module

应用领域

Municipal Water · Ultrapure Water

同系列其他配置

型号
LXV402.99.01002SC1000 Multi-parameter Universal Controller Display Module with GSM/GP
LXV402.99.02002SC1000 Multi-parameter Universal Controller Display Module with GSM/GP
LXV402.99.10002SC1000 Multi-Parameter Universal Controller Display Module with Modbus
LXV402.99.11002SC1000 Multi-parameter Universal Controller Display Module with Modbus
LXV402.99.12002SC1000 Multi-parameter Universal Controller Display Module with Modbus

资料下载

6 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Controllers and Sensors — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.

What We Did

We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Controllers and Sensors — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.

Delivery Approach

Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Controllers and Sensors — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.

Implementation

The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Controllers and Sensors — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.

Solution

The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.